12 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

Wire the appliance junction box to 110-120 VAC. This is required for use of optional accessories (standing pilot ignition) or proper operation of the appliance (Intellifire ignition).

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.

This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.

Plug the 3-volt AC transformer into the appliance junction box to supply power to the unit OR install two D cell batteries (not included) into the battery pack before use.

NOTICE: Batteries should not be placed in the battery pack while using the transformer. Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur.

C. Optional Accessories Requirements

This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.

Wiring for optional Hearth & Home Technologies ap- proved accessories should be done now to avoid re- construction. Follow instructions that come with those accessories.

B. Intellifire Ignition System Wiring

Wire the appliance junction box to 110 VAC for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.

Refer to Figure 12.1, Intellifire Pilot Ignition (IPI) Wiring Diagram.

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.

Optional

 

 

 

SPST Wall Switch

Battery

or

Optional Remote

Pack

 

RED

-

+

To

WHT

+

-

Junction

 

Box

 

 

 

GRN*

 

 

3V

 

 

Adapter

 

 

 

BLK

WHT

 

 

RED

 

 

 

 

 

 

BRN

RED

 

 

*GRN wire only for use with optional

wall switch

 

WSK-MLT

Valve

Figure 12.1 Intellifire Pilot Ignition (IPI) Wiring Diagram

Ignitor

Flame

 

Control

Sensor

 

Box ORG

Pilot Assembly

 

 

WHT

BLK

ORG

GRN

40

Heatilator • ICON DV-IDV Series • 4042-575 • Rev K • 11/08

Image 40
Contents Installation and Operation What to do if you smell gasCongratulations Homeowner Reference InformationInstaller Guide Table of ContentsUser Guide Troubleshooting Warranty Hearth & Home Technologies Limited WarrantyLimited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions Gas Fireplace SafetyYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesClear Space Decorative Doors and FrontsFor Your Safety Read Before Lighting Lighting Instructions IPIInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Any such action may cause a fire hazardSelect Appliance Location Framing and ClearancesModel # Clearances Construct the Appliance ChaseRough Opening Model # Width Height Depth Vent pipe Mantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal TerminationTwo Elbows Two 45 Elbows replacing One 90 ElbowV1 min V1 max H1+H2 max H1+H2+H3 max Installed Vertically Three ElbowsTop Vent Vertical Termination Install Flue RestrictorNo Elbow 12 ft 3.66 m min 60 ft 18.29 m max Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Secure and Level the ApplianceInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsDisassemble Vent Sections Install Metal Roof FlashingCaulk Assemble and Install Storm Collar 13 Assembling the Storm CollarInstall RF4-8 SLP-FSInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap InteriorGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Optional Accessories RequirementsIntellifire Ignition System Wiring Electrical Service and RepairJunction Box Installation Remove Two Screws From BracketFacing Material FinishingModel Noncombustible Finishing Material Finished Fireplace OpeningAppliance Setup Install the Logs Placing First Top Log IDV4833Placement of Rockwool and Lava Rock Place Lava Rock and RockwoolGlass Panel Assembly Removing/Replacing Glass AssemblyEyelet Rod Support Installing External Refractories Install Side RefractoriesOpen Refractory Package Figure Bottom Front Hearth RefractoryAir Shutter Setting 24 Air Shutter AdjustmentSymptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Will not ignite. If the pilot Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsBEK DVP-BEK2 DVP-TVHW DVP-TRAP Horizontal Termination CapDVP-HRC-SS ÎC. Service Parts IDV4833IT, IDV4833IHIPI Valve Assembly Service Parts IDV6247IT, IDV6247IHIDV6247 Traditional Refractory Pre GA1732717 Post GA1732717 Optional Components DescriptionContact Information

IDV6247ILH, IDV6247IH, IDV4833ILH, IDV4833ILT, IDV6247ILT specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, offering a range of innovative and efficient products designed for modern living. Among their impressive lineup are the IDV6247IT, IDV4833IT, IDV4833IH, IDV6247ILT, and IDV4833ILT models. These fireplaces are engineered to provide both aesthetic warmth and functional heating, catering to various consumer preferences and home designs.

The IDV6247IT is a remarkable direct vent gas fireplace that offers a spacious viewing area. With its clean lines and contemporary aesthetics, it seamlessly integrates into any living space. Equipped with advanced burner technology, it delivers realistic flames while maximizing efficiency. The model features a variety of customizable options, including remote controls and programmable thermostats, allowing users to tailor their heating preferences to suit their lifestyle.

Similarly, the IDV4833IT and IDV4833IH models offer versatile heating solutions. The IDV4833IT is designed for those seeking a traditional yet modern fireplace experience. With its customizable log sets and flame patterns, it creates a cozy ambiance. The IDV4833IH model distinguishes itself with its enhanced heating capabilities, boasting an impressive BTU output that quickly warms up expansive areas, making it ideal for larger homes.

A notable feature across these models is the innovative IntelliFire technology, which provides reliable ignition and easy operation. This ensures that the fireplace ignites effortlessly, with users able to enjoy the warmth and glow with a simple push of a button. Additionally, the fireplaces utilize a closed combustion system, drawing air from outside, which significantly increases efficiency and reduces heat loss.

For homeowners interested in a more rustic look, the IDV6247ILT and IDV4833ILT models incorporate traditional design elements. These units provide a luxurious feel with their detailed craftsmanship and realistic logs. The high-efficiency design allows for reduced emissions and lower fuel consumption, promoting a more sustainable lifestyle without compromising on warmth or comfort.

In conclusion, Hearth and Home Technologies continues to lead the way in the hearth market with their innovative IDV series. Whether you prefer contemporary elegance or classic charm, models like the IDV6247IT, IDV4833IT, IDV4833IH, IDV6247ILT, and IDV4833ILT deliver not just on style, but also on performance and efficiency. With a focus on user-friendly features and advanced technology, these fireplaces are perfect for any modern home, ensuring a warm and inviting atmosphere for years to come.