Hearth and Home Technologies IDV6247ILT Requirements for the Commonwealth of Massachusetts

Page 8

Note: The following requirements reference various Massachusetts and national codes not contained in this document.

H. Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon mon- oxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or struc- ture served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed profes- sionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) in. in size,

“GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identi- fies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Common- wealth of Massachusetts requirements.

8

Heatilator • ICON DV-IDV Series • 4042-575 • Rev K • 11/08

Image 8
Contents Installation and Operation What to do if you smell gasCongratulations Homeowner Reference InformationUser Guide Table of ContentsInstaller Guide Troubleshooting Warranty Hearth & Home Technologies Limited WarrantyLimited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesClear Space Decorative Doors and FrontsFor Your Safety Read Before Lighting Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Any such action may cause a fire hazardModel # Framing and ClearancesSelect Appliance Location Rough Opening Model # Width Height Depth Vent pipe Construct the Appliance ChaseClearances Mantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal TerminationV1 min V1 max H1+H2 max H1+H2+H3 max Two 45 Elbows replacing One 90 ElbowTwo Elbows Installed Vertically Three ElbowsNo Elbow Install Flue RestrictorTop Vent Vertical Termination 12 ft 3.66 m min 60 ft 18.29 m max Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Secure and Level the ApplianceInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsCaulk Install Metal Roof FlashingDisassemble Vent Sections Assemble and Install Storm Collar 13 Assembling the Storm CollarInstall RF4-8 SLP-FSInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap InteriorGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Optional Accessories RequirementsIntellifire Ignition System Wiring Electrical Service and RepairJunction Box Installation Remove Two Screws From BracketModel FinishingFacing Material Noncombustible Finishing Material Finished Fireplace OpeningAppliance Setup Install the Logs Placing First Top Log IDV4833Placement of Rockwool and Lava Rock Place Lava Rock and RockwoolGlass Panel Assembly Removing/Replacing Glass AssemblyEyelet Rod Support Installing External Refractories Install Side RefractoriesOpen Refractory Package Figure Bottom Front Hearth RefractoryAir Shutter Setting 24 Air Shutter AdjustmentIntellifire Ignition System TroubleshootingSymptom Possible Cause Corrective Action Will not ignite. If the pilot Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsBEK DVP-BEK2 DVP-TVHW DVP-TRAP Horizontal Termination CapDVP-HRC-SS ÎC. Service Parts IDV4833IT, IDV4833IHIPI Valve Assembly Service Parts IDV6247IT, IDV6247IHIDV6247 Traditional Refractory Pre GA1732717 Post GA1732717 Optional Components DescriptionContact Information

IDV6247ILH, IDV6247IH, IDV4833ILH, IDV4833ILT, IDV6247ILT specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, offering a range of innovative and efficient products designed for modern living. Among their impressive lineup are the IDV6247IT, IDV4833IT, IDV4833IH, IDV6247ILT, and IDV4833ILT models. These fireplaces are engineered to provide both aesthetic warmth and functional heating, catering to various consumer preferences and home designs.

The IDV6247IT is a remarkable direct vent gas fireplace that offers a spacious viewing area. With its clean lines and contemporary aesthetics, it seamlessly integrates into any living space. Equipped with advanced burner technology, it delivers realistic flames while maximizing efficiency. The model features a variety of customizable options, including remote controls and programmable thermostats, allowing users to tailor their heating preferences to suit their lifestyle.

Similarly, the IDV4833IT and IDV4833IH models offer versatile heating solutions. The IDV4833IT is designed for those seeking a traditional yet modern fireplace experience. With its customizable log sets and flame patterns, it creates a cozy ambiance. The IDV4833IH model distinguishes itself with its enhanced heating capabilities, boasting an impressive BTU output that quickly warms up expansive areas, making it ideal for larger homes.

A notable feature across these models is the innovative IntelliFire technology, which provides reliable ignition and easy operation. This ensures that the fireplace ignites effortlessly, with users able to enjoy the warmth and glow with a simple push of a button. Additionally, the fireplaces utilize a closed combustion system, drawing air from outside, which significantly increases efficiency and reduces heat loss.

For homeowners interested in a more rustic look, the IDV6247ILT and IDV4833ILT models incorporate traditional design elements. These units provide a luxurious feel with their detailed craftsmanship and realistic logs. The high-efficiency design allows for reduced emissions and lower fuel consumption, promoting a more sustainable lifestyle without compromising on warmth or comfort.

In conclusion, Hearth and Home Technologies continues to lead the way in the hearth market with their innovative IDV series. Whether you prefer contemporary elegance or classic charm, models like the IDV6247IT, IDV4833IT, IDV4833IH, IDV6247ILT, and IDV4833ILT deliver not just on style, but also on performance and efficiency. With a focus on user-friendly features and advanced technology, these fireplaces are perfect for any modern home, ensuring a warm and inviting atmosphere for years to come.