Hearth and Home Technologies COLBAY-INS Maintaining and Servicing Appliance, Glass Replacement

Page 28

11 Maintaining and Servicing Appliance

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance checkup at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Disable remote control, if one is present.

Ensure appliance is completely cooled.

After servicing:

Replace any screen or barrier that was removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Obstructions of termination cap.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fittings.

Clean:

Glass

Air passageways, grilles, control compartment

Burner, burner ports

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation.

Longer operation without cleaning glass may cause a permanent white film on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional 12 hours.

Refer to maintenance instructions.

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

A.Glass Replacement

Glass can be replaced either as three separate pieces, or as an assembly with the door. See Service Parts List.

To Replace Separate Glass Pieces

Turn off gas to the appliance.

Remove the door and set on a protective surface.

Remove the door crown.

Remove the top and bottom retainer screws from the front of the door. Set the top and bottom glass retainers aside.

Loosen the side glass retainer screws, but do not remove.

Remove the glass pieces and discard. Keep the aluminum channels for reassembly.

Slide replacement side glass into the side glass retainers.

Place the aluminum channels over the side glass.

Install the center glass into the aluminum channels.

Reinstall the glass retainers and screws. Reinstall door crown.

Door Frame with Glass Assembly Replacement

Use only Door Assembly replacement as specified in Sec- tion 8 of this manual, available from your dealer, if any glass becomes broken in the Columbia Bay Insert.

Follow the previous instructions to install the door crown and grille to the new Door Assembly.

Note: The glass and gasketing must be replaced as a complete unit as supplied by the manufacturer. Do not use substitute material.

28

Quadra-Fire • Columbia Bay Insert • 7002-109 Rev. H • 10/08

Image 28
Contents COLBAY-INS What to do if you smell gasDo Discardnot Welcome to the Quadra-Fire Family Table of Contents Listing and Code Approvals Getting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Framing and Clearances Selecting Appliance LocationClearances to Combustibles HearthTermination Locations Vent Termination Minimum ClearancesVenting and Installation Vent InformationExhaust AIR Vent Pipe Termination CAP Adaptor Fuel Conversions Gas InformationConverting to LP Gas Valve Regulator Replacement Gas Pressures Gas ConnectionHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthPilot Appliance Setup AccessoriesDoor Crown Installation Remove Shipping MaterialsPanel Set Installation Grille InstallationBack of TOP Panel Screws Back of Side Panel Brick Installation Baffle SupportsBaffle Rear Brick Panel Brick ClipsPositioning the Logs Mineral Wool Blower InstallationIncluded in kit Blower = 1/4 in mm female spade = 1/4 in mm male spade Air Shutter Adjustment Operating Instructions Before Lighting ApplianceFor Your Safety Read Before Lighting Lighting ApplianceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionGlass Replacement Door Frame with Glass Assembly ReplacementMaintaining and Servicing Appliance To Replace Separate Glass PiecesMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components List HHTLog Set Assembly Service PartsService Parts List Stocked At DepotBottom Firebox Assembly Description Serial # Part NumberCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

COLBAY-INS specifications

Hearth and Home Technologies (HHT) has made significant strides in the hearth industry, and one of its standout offerings is the COLBAY-INS. This innovative indoor fireplace embodies the company's commitment to quality, efficiency, and design flexibility, catering to modern homeowners seeking a spectacular focal point for their living spaces.

The COLBAY-INS integrates state-of-the-art technology with elegant design. One of its most remarkable features is the advanced heat management system that optimally distributes warmth throughout the room. By utilizing a powerful, efficiency-driven heating mechanism, the COLBAY-INS ensures that energy consumption is minimized while still providing exceptional warmth. With an impressive thermal efficiency rating, it combines comfort and sustainability, making it an excellent choice for modern homes.

Another distinguishing characteristic of the COLBAY-INS is its large viewing area. The expansive glass front allows for an unobstructed view of the flames, creating a captivating ambiance that transforms any indoor setting. This allows homeowners to enjoy the aesthetic appeal of a traditional fire without the hassle and mess associated with wood-burning fireplaces. The glass is designed to be heat-resistant and easy to clean, ensuring that the beauty of the flames remains the focal point.

The COLBAY-INS also incorporates smart technology for enhanced user convenience. With options for remote operation and smart home integration, users can easily control the fireplace's settings from their smartphones or smart devices. This feature not only adds a layer of comfort but also allows for seamless integration into all home automation systems.

Safety is paramount in the design of the COLBAY-INS. It includes multiple safety features, such as a secure door mechanism that keeps flames contained and a built-in safety shut-off function that activates in the event of an overheating situation. The overall construction adheres to the highest safety standards, giving homeowners peace of mind.

Moreover, the COLBAY-INS offers a variety of customization options, including different hearth finishes and media beds. This ensures that it can beautifully complement any interior design theme, from sleek contemporary to rustic charm. Additionally, the dual-fuel capability allows users to choose between natural gas and propane, providing flexibility based on personal preferences and availability.

In summary, Hearth and Home Technologies' COLBAY-INS is an exceptional indoor fireplace that combines efficient heating, modern technology, and stylish design. With its impressive features, safety standards, and customization options, it serves as a beautiful centerpiece while enhancing the overall comfort of any home.