Hearth and Home Technologies COLBAY-INS Electrical Information, Recommendation for Wire

Page 14

7 Electrical Information

A. Recommendation for Wire

See Figure 7.1 for recommended maximum lead length (two wire) when using wall thermostat/switch.

NOTE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C221.1.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Do not connect this appliance to a thermostat serving any other appliance.

Bedroom installation in Canada requires this appliance to be connected to a thermostat.

WARNING

Shock hazard.

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or remove the ground- ing prong from this plug.

B. Connecting to the Appliance

1.This appliance may be used with a wall switch, wall mounted thermostat and / or a remote control

2.If using thermostat, use one compatible with a millivolt gas valve system.

3.Follow parameters for locating thermostat (see individ- ual thermostat instructions) to ensure proper operation of appliance.

4.Use low resistance thermostat wire for wiring from ignition system to the wall switch and thermostat.

5.Use the following chart for wire sizing.

Wire Size

Max. Length

16 gauge

65 feet

18 gauge

40 feet

20 gauge

25 feet

22 gauge

18 feet

Figure 7.1

6.Keep wire lengths as short as possible by removing any excess wire length.

7.Low voltage and 110 VAC voltage cannot be shared within the same wall box.

8.Ensure the thermostat is mounted level for accurate readings.

9.The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air.

10.If the thermostat is located too close to the appli- ance, you may need to set the temperature setting slightly higher to maintain the desired temperature in your home.

C. Standing Pilot Ignition System Wiring

This appliance DOES NOT require 110 VAC supply for operation. A wiring diagram is shown in Figure 7.2 on the next page.

This appliance is equipped with a millivolt control valve.

14

Quadra-Fire • Columbia Bay Insert • 7002-109 Rev. H • 10/08

Image 14
Contents Do Discardnot What to do if you smell gasCOLBAY-INS Welcome to the Quadra-Fire Family Table of Contents Listing and Code Approvals Tools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Clearances to Combustibles Framing and ClearancesSelecting Appliance Location HearthTermination Locations Vent Termination Minimum ClearancesVenting and Installation Vent InformationExhaust AIR Vent Pipe Termination CAP Adaptor Converting to LP Gas Gas InformationFuel Conversions Valve Regulator Replacement Gas Pressures Gas ConnectionHigh Altitude Installations Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthPilot Door Crown Installation Appliance SetupAccessories Remove Shipping MaterialsBack of TOP Panel Screws Back of Side Panel Grille InstallationPanel Set Installation Baffle Rear Brick Panel Brick InstallationBaffle Supports Brick ClipsPositioning the Logs Included in kit Blower Blower InstallationMineral Wool = 1/4 in mm female spade = 1/4 in mm male spade Air Shutter Adjustment Operating Instructions Before Lighting ApplianceFor Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionMaintaining and Servicing Appliance Glass ReplacementDoor Frame with Glass Assembly Replacement To Replace Separate Glass PiecesMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components List HHTLog Set Assembly Service PartsService Parts List Stocked At DepotBottom Firebox Assembly Description Serial # Part NumberCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

COLBAY-INS specifications

Hearth and Home Technologies (HHT) has made significant strides in the hearth industry, and one of its standout offerings is the COLBAY-INS. This innovative indoor fireplace embodies the company's commitment to quality, efficiency, and design flexibility, catering to modern homeowners seeking a spectacular focal point for their living spaces.

The COLBAY-INS integrates state-of-the-art technology with elegant design. One of its most remarkable features is the advanced heat management system that optimally distributes warmth throughout the room. By utilizing a powerful, efficiency-driven heating mechanism, the COLBAY-INS ensures that energy consumption is minimized while still providing exceptional warmth. With an impressive thermal efficiency rating, it combines comfort and sustainability, making it an excellent choice for modern homes.

Another distinguishing characteristic of the COLBAY-INS is its large viewing area. The expansive glass front allows for an unobstructed view of the flames, creating a captivating ambiance that transforms any indoor setting. This allows homeowners to enjoy the aesthetic appeal of a traditional fire without the hassle and mess associated with wood-burning fireplaces. The glass is designed to be heat-resistant and easy to clean, ensuring that the beauty of the flames remains the focal point.

The COLBAY-INS also incorporates smart technology for enhanced user convenience. With options for remote operation and smart home integration, users can easily control the fireplace's settings from their smartphones or smart devices. This feature not only adds a layer of comfort but also allows for seamless integration into all home automation systems.

Safety is paramount in the design of the COLBAY-INS. It includes multiple safety features, such as a secure door mechanism that keeps flames contained and a built-in safety shut-off function that activates in the event of an overheating situation. The overall construction adheres to the highest safety standards, giving homeowners peace of mind.

Moreover, the COLBAY-INS offers a variety of customization options, including different hearth finishes and media beds. This ensures that it can beautifully complement any interior design theme, from sleek contemporary to rustic charm. Additionally, the dual-fuel capability allows users to choose between natural gas and propane, providing flexibility based on personal preferences and availability.

In summary, Hearth and Home Technologies' COLBAY-INS is an exceptional indoor fireplace that combines efficient heating, modern technology, and stylish design. With its impressive features, safety standards, and customization options, it serves as a beautiful centerpiece while enhancing the overall comfort of any home.