Hearth and Home Technologies GARNET-MBK owner manual How to Use the Vent Graph Venting Guidelines

Page 11

D. How to Use the Vent Graph

E. Venting Guidelines

1.Measure the vertical distance from the center line of the flue pipe to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis across until it intersects with the slanted line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.The point at which this line meets the bottom line of the graph is the maximum length of the horizontal run.

EXAMPLE 1: If the vertical dimension from the center line of the flue vent to the center of the 90° elbow is 7 ft. (2m), the horizontal run to the outer wall flange must not exceed 9 ft.-8 in. (3m).

EXAMPLE 2: If the vertical dimension from the center line of the flue vent is 21 ft. (6m), the horizontal run to the outer wall flange must not exceed 4 ft.-3 in. (1m).

4.Each 90° elbow is equivalent to 3 ft. (914mm) of vent pipe and each 45° elbow is equivalent to 1 ft. (305mm) of vent pipe, and must be subtracted from the vent pipe run. A single horizontal to vertical 90° elbow is already calculated into the allowable 15 ft. (5m) run. Each additional 90° elbow reduces the maximum horizontal distance by 3 ft. (914mm).

EXAMPLE: The use of 3 elbows would reduce the allowable horizontal run to 9 ft. (3 -1 = 2 elbows x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.).

NOTES

The maximum horizontal vent run is 15 ft. (5m) when the vertical vent rise is 10 ft. (3m).

Horizontal sections require a 1/4 in. (6mm) rise for every 12 in. (305mm) of horizontal travel.

Exterior Vent Diameter = 6-5/8 in. (168mm); Inner Vent Diameter = 4 in. (102mm)

Horizontal sections require noncombustible support every 3 ft. (914mm), e.g. wall straps.

For any vertical termination a minimum of 6 in. (152mm) vertical must be used.

EXCEPTIONS

FOR HORIZONTAL INSTALLATIONS:

The maximum horizontal vent run is 30 in. (762mm).

The maximum horizontal vent run with a 45° elbow is 18 in. (457mm).

No external minimum rise is required.

The minimum horizontal vent run is 6 in. (152mm).

NOTE: If your installation falls within the gray-shaded area on graph, see information on intake damper operation, on page 36.

*In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor.

25 ft. (8m)

25'

 

 

 

 

 

 

 

 

Maximum Vertical

24'

 

 

 

 

 

 

 

 

Example 2

22'

 

 

 

 

 

 

 

 

 

20'

 

 

 

 

 

 

 

 

 

18'

Adjust

 

 

 

 

 

 

 

 

16'

Intake

 

 

 

 

 

 

 

VERTICAL DISTANCE

Damper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14'

 

 

 

 

 

 

 

 

FROM APPLIANCE TO

 

Install Flue

 

 

 

 

 

 

 

 

 

 

90° ELBOW

12'

 

 

Restrictor

 

 

 

 

 

10'

 

 

 

 

 

 

 

 

Example 1

8'

 

 

 

 

 

 

 

Termination

 

 

 

 

 

 

 

 

 

6'

 

 

 

 

 

 

 

cap

 

 

 

 

 

 

 

 

 

6 ft. (2m) Minimum

4'

 

 

 

 

 

 

 

 

Vertical Termination

 

 

 

 

 

 

 

 

2'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

L

 

2'

4'

6'

8'

10'

12'

14'

15'

 

 

 

 

 

 

Termination Cap

 

 

 

 

6 in. (152mm)

 

30 in. (762mm) Maximum Horizontal run with no

 

Minimum starter pipe

vertical pipe and with 1/4 in. (6mm) rise per foot.

Figure 5.2

 

 

 

Must use approved Termination Cap.

September 1, 2008

Quadra-Fire · Garnet-T · 7016-127F

Page 11

Image 11
Contents Hot glass will cause burns What to do if you smell gasDo not Discard this Manual Do DiscardnotManufactured Date Serial Number Model Name Test Lab & Report NoTable of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Tools and Supplies Needed Tools will apply to every installationGetting Started Clearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Do not USE FIELD-FABRICATED Venting Vent InformationVenting Components Use of Elbows Measuring StandardsExceptions For Horizontal Installations How to Use the Vent Graph Venting GuidelinesStep Type B Rear Installations for Use with Rear Vent KitFire Risk. Explosion Risk. Combustion Fume Risk 203mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type B Existing Masonry ChimneyType D Hearth Mount Cut and bend flashing as needed to fit Sealant adhesive Retro Connector Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble Before YOU BeginTrim Ring Propane Natural GAS Gas InformationFuel Conversions Converting to LP GasValve Regulator Replacement Pressure Gas Pressures Gas ConnectionCheck for GAS Leaks Wire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringIgnition Module Leg Leveling System Appliance SetupFlue Restrictor Installation Remove Shipping MaterialsMineral Wool AccessoriesPositioning the Logs KIT Contents Glass ReplacementBlower Installation Snap Disc White Intake Damper Operation Ignition Module Access and Battery ReplacementShutter Adjustment Controls Operating InstructionsBefore Lighting Appliance Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramSeptember 1 Quadra-Fire · Garnet-T · 7016-127F Vent Components DiagramMm inner pipe 6-5/8 in mm outer pipe HHT SL-P Vent Components ListTermination Caps & Kits Description GARNET-TService Parts List cont’d. GARNET-T Service Parts List cont’d. GARNET-T Accessories Date of Service Performed By Description of Service Service And Maintenance LogHomeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Dealer Telephone Garnet-TContact Information

GARNET-D-CSB, GARNET-D-CWL, GARNET-MBK, GARNET-D-PMH, GARNET-D-MBK specifications

Hearth and Home Technologies has a reputation for excellence in the home heating and comfort industry, offering a range of top-tier products that combine modern design with functionality. Among their esteemed offerings are the GARNET-D-MBK, GARNET-D-PMH, GARNET-MBK, GARNET-D-CWL, and GARNET-D-CSB units, each designed to meet diverse consumer preferences while promoting efficiency and style.

The GARNET-D-MBK model, characterized by its sleek black finish, seamlessly integrates into contemporary living spaces. It boasts an efficient heating system that utilizes advanced combustion technology to maximize heat output while minimizing emissions. Its easy-to-use interface ensures users can control the device with minimal effort, making it ideal for both seasoned and first-time stove owners.

In contrast, the GARNET-D-PMH features a polished mahogany finish that appeals to those wanting a classic aesthetic. This model incorporates cutting-edge burn technology, which not only enhances heat retention but also significantly reduces the time required to achieve optimal temperatures. With its thoughtful design and craftsmanship, the GARNET-D-PMH stands as a beautiful centerpiece in any room.

Moving on to the GARNET-MBK, this model offers the same high efficiency as its counterparts with an added advantage of a modular design. This adaptability allows homeowners to customize the unit based on their specific space requirements. Its multiple heating settings cater well to varying temperatures, contributing to its reputation as an energy-efficient alternative.

The GARNET-D-CWL model is distinguished by its compact design and rugged construction. This product was engineered for utility while maintaining aesthetic appeal. The unit’s innovative technology not only ensures impressive heat output but also incorporates safety features that make it a reliable choice for families.

Lastly, the GARNET-D-CSB encapsulates the essence of versatility. This model effortlessly balances function and design, featuring an elegant coating that enhances durability. Its digital controls offer precision in temperature management, while its efficient energy use aligns with modern environmental standards.

Across all these models, Hearth and Home Technologies prioritizes quality, utilizing durable materials and state-of-the-art engineering techniques. Their commitment to customer satisfaction and environmental responsibility is evident in every unit, making these garnet series products standout choices for effective home heating solutions.