Hearth and Home Technologies GARNET-D-PMH Electrical Information, Recommendation for Wire

Page 29

7Electrical Information

A. Recommendation for Wire

See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch.

NOTE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA

C221.1.

B. Connecting to the Appliance

WARNING

Wire 110v to electrical junction box.

Do NOT wire 110v to the valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt systems.

1.This appliance may be used with a wall switch, wall mounted thermostat and / or a remote control.

2.If using thermostat, use one compatible with a millivolt gas valve system.

3.Follow parameters for locating thermostat (see individ- ual thermostat instructions) to ensure proper operation of appliance.

4.Use low resistance thermostat wire for wiring from igni- tion system to the wall switch and thermostat.

5.Use the following chart for wire sizing.

Wire Size

Max. Length

16 gauge

65 feet

18 gauge

40 feet

20 gauge

25 feet

22 gauge

18 feet

8.Ensure the thermostat is mounted level for accurate readings.

9.The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air.

10.If the thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired temperature in your home.

Do not connect this appliance to a thermostat serving any other appliance.

Bedroom installation in Canada requires this appliance to be connected to a thermostat.

WARNING

Shock hazard.

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or remove the grounding prong from this plug.

C.Standing Pilot Ignition System Wiring

This appliance DOES NOT require 110 VAC supply for operation. A wiring diagram is shown in Figure 7.1 on the next page.

This appliance is equipped with a millivolt control valve.

6.Keep wire lengths as short as possible by removing any excess wire length.

7.Low voltage and 110 VAC voltage cannot be shared within the same wall box.

September 1, 2008

Quadra-Fire · Garnet-T · 7016-127F

Page 29

Image 29
Contents Do not Discard this Manual What to do if you smell gasDo Discardnot Hot glass will cause burnsManufactured Date Serial Number Model Name Test Lab & Report NoTable of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Tools and Supplies Needed Tools will apply to every installationGetting Started Clearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Venting Components Use of Elbows Vent InformationMeasuring Standards Do not USE FIELD-FABRICATED VentingExceptions For Horizontal Installations How to Use the Vent Graph Venting GuidelinesStep Type B Rear Installations for Use with Rear Vent KitFire Risk. Explosion Risk. Combustion Fume Risk 203mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type B Existing Masonry ChimneyType D Hearth Mount Cut and bend flashing as needed to fit Sealant adhesive Retro Connector Slim Line Wall Thimble Installing Slim Line Trim Ring and Heat ShieldBefore YOU Begin Assembling Slim Line Trim Ring and Heat ShieldTrim Ring Fuel Conversions Gas InformationConverting to LP Gas Propane Natural GASValve Regulator Replacement Pressure Gas Pressures Gas ConnectionCheck for GAS Leaks Connecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Wire Size Max. LengthIgnition Module Flue Restrictor Installation Appliance SetupRemove Shipping Materials Leg Leveling SystemMineral Wool AccessoriesPositioning the Logs KIT Contents Glass ReplacementBlower Installation Snap Disc White Intake Damper Operation Ignition Module Access and Battery ReplacementShutter Adjustment Controls Operating InstructionsBefore Lighting Appliance Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramSeptember 1 Quadra-Fire · Garnet-T · 7016-127F Vent Components DiagramMm inner pipe 6-5/8 in mm outer pipe HHT SL-P Vent Components ListTermination Caps & Kits Description GARNET-TService Parts List cont’d. GARNET-T Service Parts List cont’d. GARNET-T Accessories Date of Service Performed By Description of Service Service And Maintenance LogHomeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Dealer Telephone Garnet-TContact Information

GARNET-D-CSB, GARNET-D-CWL, GARNET-MBK, GARNET-D-PMH, GARNET-D-MBK specifications

Hearth and Home Technologies has a reputation for excellence in the home heating and comfort industry, offering a range of top-tier products that combine modern design with functionality. Among their esteemed offerings are the GARNET-D-MBK, GARNET-D-PMH, GARNET-MBK, GARNET-D-CWL, and GARNET-D-CSB units, each designed to meet diverse consumer preferences while promoting efficiency and style.

The GARNET-D-MBK model, characterized by its sleek black finish, seamlessly integrates into contemporary living spaces. It boasts an efficient heating system that utilizes advanced combustion technology to maximize heat output while minimizing emissions. Its easy-to-use interface ensures users can control the device with minimal effort, making it ideal for both seasoned and first-time stove owners.

In contrast, the GARNET-D-PMH features a polished mahogany finish that appeals to those wanting a classic aesthetic. This model incorporates cutting-edge burn technology, which not only enhances heat retention but also significantly reduces the time required to achieve optimal temperatures. With its thoughtful design and craftsmanship, the GARNET-D-PMH stands as a beautiful centerpiece in any room.

Moving on to the GARNET-MBK, this model offers the same high efficiency as its counterparts with an added advantage of a modular design. This adaptability allows homeowners to customize the unit based on their specific space requirements. Its multiple heating settings cater well to varying temperatures, contributing to its reputation as an energy-efficient alternative.

The GARNET-D-CWL model is distinguished by its compact design and rugged construction. This product was engineered for utility while maintaining aesthetic appeal. The unit’s innovative technology not only ensures impressive heat output but also incorporates safety features that make it a reliable choice for families.

Lastly, the GARNET-D-CSB encapsulates the essence of versatility. This model effortlessly balances function and design, featuring an elegant coating that enhances durability. Its digital controls offer precision in temperature management, while its efficient energy use aligns with modern environmental standards.

Across all these models, Hearth and Home Technologies prioritizes quality, utilizing durable materials and state-of-the-art engineering techniques. Their commitment to customer satisfaction and environmental responsibility is evident in every unit, making these garnet series products standout choices for effective home heating solutions.