Hearth and Home Technologies GARNET-D-CSB, GARNET-MBK Vertical Termination, Direct Vent Pipe

Page 15

G.Vertical Termination

1. Direct Vent Pipe

WARNING

Fire Risk.

Explosion Risk.

STORM

COLLAR

FIRESTOP

PIPE LENGTH

VERTICAL

TERMINATION

CAP

FLASHING

SUPPORT BOX

Maintain vent clearance to combustibles as speci- fied.

• Do not pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause fire.

25 ft. (8m)

MAXIMUM

Figure 5.11

Step 2.

Figure 5.10

Step 1.

Check the installation instructions for required 1 in. (25mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. See page 17, Figure

5.16.Check the instructions below for maximum vertical rise of the venting system, and any maximum horizontal offset limitations. All offsets must fall within the set parameters of the vent graph (Figure 5.2) located on page 11.

NOTE: Maximum vertical rise allowable is 25 ft. (8m) Figure 5.11).

NOTE: Maximum number of 45° elbows permitted for a vertical installation is eight, provided their installation does not decrease maximum allowable horizontal run (as specified by vent graph, on page 11).

Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to relocate the appliance, or to offset, as shown in Figure 5.12, on the next page, to avoid cutting loadbearing members. When location is determined, drill small hole.

September 1, 2008

Quadra-Fire · Garnet-T · 7016-127F

Page 15

Image 15
Contents Hot glass will cause burns What to do if you smell gasDo not Discard this Manual Do DiscardnotManufactured Date Serial Number Model Name Test Lab & Report NoTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Tools will apply to every installation Getting StartedTools and Supplies Needed Clearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Do not USE FIELD-FABRICATED Venting Vent InformationVenting Components Use of Elbows Measuring StandardsExceptions For Horizontal Installations How to Use the Vent Graph Venting GuidelinesStep Type B Rear Installations for Use with Rear Vent KitFire Risk. Explosion Risk. Combustion Fume Risk 203mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type D Hearth MountType B Cut and bend flashing as needed to fit Sealant adhesive Retro Connector Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble Before YOU BeginTrim Ring Propane Natural GAS Gas InformationFuel Conversions Converting to LP GasValve Regulator Replacement Pressure Gas Pressures Gas ConnectionCheck for GAS Leaks Wire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringIgnition Module Leg Leveling System Appliance SetupFlue Restrictor Installation Remove Shipping MaterialsAccessories Positioning the LogsMineral Wool Glass Replacement Blower InstallationKIT Contents Snap Disc White Ignition Module Access and Battery Replacement Shutter AdjustmentIntake Damper Operation Operating Instructions Before Lighting ApplianceControls Lighting Appliance For Your Safety Read Before LightingFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramVent Components Diagram Mm inner pipe 6-5/8 in mm outer pipeSeptember 1 Quadra-Fire · Garnet-T · 7016-127F HHT SL-P Vent Components ListTermination Caps & Kits Description GARNET-TService Parts List cont’d. GARNET-T Service Parts List cont’d. GARNET-T Accessories Date of Service Performed By Description of Service Service And Maintenance LogHomeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Garnet-T Contact InformationDealer Telephone

GARNET-D-CSB, GARNET-D-CWL, GARNET-MBK, GARNET-D-PMH, GARNET-D-MBK specifications

Hearth and Home Technologies has a reputation for excellence in the home heating and comfort industry, offering a range of top-tier products that combine modern design with functionality. Among their esteemed offerings are the GARNET-D-MBK, GARNET-D-PMH, GARNET-MBK, GARNET-D-CWL, and GARNET-D-CSB units, each designed to meet diverse consumer preferences while promoting efficiency and style.

The GARNET-D-MBK model, characterized by its sleek black finish, seamlessly integrates into contemporary living spaces. It boasts an efficient heating system that utilizes advanced combustion technology to maximize heat output while minimizing emissions. Its easy-to-use interface ensures users can control the device with minimal effort, making it ideal for both seasoned and first-time stove owners.

In contrast, the GARNET-D-PMH features a polished mahogany finish that appeals to those wanting a classic aesthetic. This model incorporates cutting-edge burn technology, which not only enhances heat retention but also significantly reduces the time required to achieve optimal temperatures. With its thoughtful design and craftsmanship, the GARNET-D-PMH stands as a beautiful centerpiece in any room.

Moving on to the GARNET-MBK, this model offers the same high efficiency as its counterparts with an added advantage of a modular design. This adaptability allows homeowners to customize the unit based on their specific space requirements. Its multiple heating settings cater well to varying temperatures, contributing to its reputation as an energy-efficient alternative.

The GARNET-D-CWL model is distinguished by its compact design and rugged construction. This product was engineered for utility while maintaining aesthetic appeal. The unit’s innovative technology not only ensures impressive heat output but also incorporates safety features that make it a reliable choice for families.

Lastly, the GARNET-D-CSB encapsulates the essence of versatility. This model effortlessly balances function and design, featuring an elegant coating that enhances durability. Its digital controls offer precision in temperature management, while its efficient energy use aligns with modern environmental standards.

Across all these models, Hearth and Home Technologies prioritizes quality, utilizing durable materials and state-of-the-art engineering techniques. Their commitment to customer satisfaction and environmental responsibility is evident in every unit, making these garnet series products standout choices for effective home heating solutions.