G. Install Roof Flashing and Vertical Termination Cap

To install roof fl ashing see Figure 2.19.

For installation of vertical termination cap see minimum vent heights for various pitched roofs (Figure 2.19) .

To attach the vertical termination cap, slide the inner collar of the cap into the inner fl ue of the pipe section and place the outer collar of the cap over the outer fl ue of the pipe section.

24 in. min.

(610 mm)

Termination

Cap

Storm Collar

Roof

Flashing

Horizontal overhang

20 in.

(508 mm)

Vertical

Lowestwall Discharge

Opening

X

12

Roof Pitch is X / 12

H (min.) - Minimum height from roof to lowest discharge opening.

Secure with three screws into the outer fl ue. Secure the cap by driving the three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer fl ue of the pipe (see Figure 2.20).

Termination Cap

Brackets/

 

(1 of three)

 

 

 

Bolts

 

 

Storm

Collar

Screws

Caulk

Figure 2.20 Secure with Screws

Roof Pitch

H (Min.) Ft.

Roof Pitch

H (Min.) Ft.

Flat to 6/12

 

1.0*

Over 11/12 to 12/12

4.0

6/12 to 7/12

 

1.25*

Over 12/12 to 14/12

5.0

Over 7/12 to 8/12

1.5*

Over 14/12 to 16/12

6.0

Over 8/12 to 9/12

2.0*

Over 16/12 to 18/12

7.0

Over 9/12 to 10/12

2.5

Over 18/12 to 20/12

7.5

Over 10/12 to 11/12

3.25

Over 20/12 to 21/12

8.0

 

* 3 ft. minimum in snow regions

 

 

Figure 2.19 Minimum Height from Roof to Lowest Discharge Opening

WARNING

Fire Risk

Explosion Risk

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

Hearth & Home Technologies Inc. • Cinch Pipe & Term Caps • 4033-900 Rev K • 05/05

11

Image 11
Contents Any such action may cause a fire hazard Installation InstructionsNot shown Parts and DescriptionsCool ADD Trap CAP Specification Chart Rear Vented Direct Vent Appliances Clearances for the Vent SectionsPenetrating a Wall Top Vented Direct Vent AppliancesFire Risk Exhaust Fumes Risk Attaching Vent to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Assemble Minimum Installation MI SectionsFire Risk Explosion Risk Asphyxiation Risk Disassemble Vent SectionsSecure the Vent Sections Heat Shield Requirements for Horizontal Termination Install the Heat Shield and Horizontal Termination CapInstall the Horizontal Termination Cap Burn RiskFire Risk Install the Firestop SpacerInstall Attic Insulation Shield Vertical Penetration Framing20 Secure with Screws Roof Pitch Min. Ft Install Roof Flashing and Vertical Termination CapCaulk around the top of the storm collar Assemble and Install Storm Collar

Cinch Pipe & Termination Cap System specifications

Hearth and Home Technologies has made significant strides in enhancing the efficiency and safety of venting systems with its innovative Cinch Pipe & Termination Cap System. This advanced system addresses the needs of modern heating solutions, offering a reliable and efficient means of venting gas appliances while simplifying installation.

One of the standout features of the Cinch Pipe System is its easy-to-use design. The system utilizes a push-together installation method, which minimizes assembly time and reduces the complexity typically associated with venting systems. This innovative approach enables both DIYers and professionals to install the system with minimal tools and time, making it an attractive option for various settings, including residential and commercial applications.

The Cinch Pipe is crafted from high-quality materials, ensuring durability and longevity. Made from stainless steel, it is designed to withstand harsh weather conditions and resist corrosion, thereby extending the life of the venting system. In conjunction with the termination cap, it provides a secure seal that prevents leaks and ensures proper exhaust flow, contributing to the safe operation of gas appliances.

One of the characteristics that sets the Cinch Pipe apart is its impressive flexibility. The system can be used for a variety of appliance types, including direct vent and B-vent applications. This versatility makes it an excellent choice for builders and contractors who require a reliable venting solution regardless of the project specifications.

Additionally, the termination cap of the Cinch Pipe system is designed with safety in mind. It features built-in insect screens to prevent the entry of unwanted pests while also providing superior weather protection. The cap is engineered to optimize exhaust flow, thereby enhancing the efficiency of the connected appliance.

The Hearth and Home Technologies Cinch Pipe & Termination Cap System exemplifies a commitment to both innovation and safety. With its user-friendly installation, robust construction, and versatile application range, it stands out as a premier choice for those looking for quality venting solutions. This system not only meets the demands of efficiency and safety but also enhances the overall performance of gas-heating appliances, making it an essential component in modern venting technology.