Hearth and Home Technologies Cinch Pipe & Termination Cap System Clearances for the Vent Sections

Page 5

2Installing Vent Pipe

Note: For termination cap installations only, go directly to Sec- tion E.

Note: Heat shields MUST overlap by 1-1/2 in. min. for rear vented appliances.

A. Clearances for the Vent Sections

Top Vented Direct Vent Appliances

For all top vented, direct vent appliances, clearances to combustible materials from the venting system need to be maintained as shown in Figure 2.1.

Rear Vented Direct Vent Appliances

See Figure 2.2.

Note: Refer to the appliance installation instructions for al- lowed vent lengths and configurations.

B. Penetrating a Wall

Wherever a combustible wall is penetrated, the hole must be framed with an interior wall shield (DVP-WS) as shown in Figures 2.3-2.4. This shield maintains minimum clearances and restricts cold air infi ltration. If the wall being penetrated is of noncombustible materials (material which will not ignite or burn, or has a UL fi re rating of zero), a 9 in. diameter hole is acceptable. Whenever a wall is penetrated the wall shield is only required on one side and no heat shield is necessary. If your local inspector requires the wall shield on both sides, then both wall shields must have a heat shield attached to them.

Figure 2.1 Horizontal Venting Clearances to Combustible Materi- als - Top Vent

Figure 2.3 Exterior Wall Hole

Heat

Shield

Wall

Shield

WALL

Note: Heat shields MUST overlap by a minimum of

1-1/2 in. (38 mm).

3 in. (76 mm) top clearance

Heat

Shield

1 in. (25 mm) clearance bottom & sides

Figure 2.4 Interior Wall Shield

WARNING

Fire Risk Explosion Risk

Maintain vent clearance to combustibles as specifi ed.

Do not pack air space with insulation or other materials.

Figure 2.2 Horizontal Venting Clearances to Combustible Materi- als - Rear Vent

Failure to keep insulation or other materials away from vent pipe may cause fi re.

Hearth & Home Technologies Inc. • Cinch Pipe & Term Caps • 4033-900 Rev K • 05/05

5

Image 5 Contents
Any such action may cause a fire hazard Installation InstructionsNot shown Parts and DescriptionsCool ADD Trap CAP Specification Chart Penetrating a Wall Clearances for the Vent SectionsTop Vented Direct Vent Appliances Rear Vented Direct Vent AppliancesAssemble Vent Sections Attaching Vent to the Firebox AssemblyAssemble Pipe Sections Fire Risk Exhaust Fumes RiskAssemble Slip Sections Assemble Minimum Installation MI SectionsFire Risk Explosion Risk Asphyxiation Risk Disassemble Vent SectionsSecure the Vent Sections Install the Horizontal Termination Cap Install the Heat Shield and Horizontal Termination CapBurn Risk Heat Shield Requirements for Horizontal TerminationInstall Attic Insulation Shield Install the Firestop SpacerVertical Penetration Framing Fire Risk20 Secure with Screws Roof Pitch Min. Ft Install Roof Flashing and Vertical Termination CapCaulk around the top of the storm collar Assemble and Install Storm Collar