Hearth and Home Technologies EM-415H owner manual Accessories, Gas Log/Lighter Provisions

Page 24

7

Accessories

 

 

 

 

 

A. Gas Log/Lighter Provisions

 

 

WARNING

 

A certified gas log lighter or decorative gas log set can be

 

installed in this fireplace.

 

 

Asphyxiation Risk

 

• Maximum input is 100,000 BTU/hr.

 

• Damper must be locked open when gas logs

 

• Decorative gas appliance must be certified to ANSI Z21.60

installed.

 

“Standard for Decorative Gas Appliances for Installation

Gas fire generates fumes.

 

in Vented Fireplaces”.

 

 

 

Must be installed in accordance with the National Fuel

Gas Code, ANSI Z223.1.

A log set must incorporate a gas shutoff.

Log set requires the damper to be locked fully open.

Knockouts are provided on both sides of the fireplace and in refractories for 1/2 in. (13 mm) iron pipe.

We recommend you seal refractory around pipe with fireplace mortar or high temperature, noncombustible sealant.

Repack insulation from the knockout around the pipe.

Maintain 1-1/2 in. (38 mm) air space around the pipe for 4 in. (102 mm) beyond the fireplace.

See Figure 7.1.

WARNING

Fire Risk

For use with solid wood fuel or decorative gas appliance only.

DO NOT install unvented gas logs.

WARNING

Fire Risk

Explosion Risk

Inspect appliance and components for damage. Damaged parts may impair safe operation.

Firebox

Refractory

Seal with fireplace mortar or high temp noncombustible sealant

Outer Shell

of Fireplace

Maintain air clearance to combustibles.

Combustible

Materials

Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components

Report damaged parts to dealer.

B. Junction Box Installation

Your appliance is supplied with a Junction Box Kit. We rec- ommend the junction box be installed and wired at this time to avoid reconstruction.

Gas Line

Repack

Insulation

Knockout

 

 

 

 

 

 

 

 

 

 

 

1-1/2 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(38 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Line

 

 

 

 

 

air space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible materials

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

may be located at zero

 

 

 

 

 

 

 

 

 

 

 

 

clearance to gas line

 

 

 

 

 

 

 

 

 

 

 

 

beyond 4 in. (102 mm)

 

 

 

4 in.

 

 

from fireplace side.

 

 

 

 

 

 

(102 mm)

 

 

 

 

 

 

• The Junction Box Kit is to be installed on the right side of

the appliance; remove and discard the metal knockout.

• Attach the junction box bracket to the junction box as

shown in Figures 7.2 - 7.4.

• Bring the electrical wires to the inside of the junction box

and secure in place with the Romex connector.

• Install the duplex receptacle in the junction box and attach

the cover plate.

• Prior to attaching the junction box to the appliance, the

heat shield supplied with your appliance must be installed.

Insert the top flange of the heat shield through the electrical

Figure 7.1 Gas Line Installation

knockout hole from the inside (Figure 7.5).

Attach the junction box bracket to the side of the appliance by slipping the bottom flange into the knockout hole. See Figure 7.5. Secure with the three screws provided in the fastener package.

24

Heat & Glo • EM-415/EM-415H • 31317 Rev Q • 10/06

Image 24
Contents Models EM-415 EM-415H Woodburning Fireplace Fire RiskListing Label Information/Location GrateNumber Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Design and Installation Considerations Getting StartedNegative Pressure Asphyxiation RiskMarginal Location Typical Fireplace System Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the Fireplace¨E. Construct the Chase Chimney RequirementsInstallation of Fireplace Install the Outside Air KitFire Risk Sharp Edges Asphyxiation Risk Risk of Smoke SpillageFt min. from top of uppermost chimney section to air inlet Secure the Fireplace Position the FireplacePlace the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Height of Chimney Components Using Offsets/Returns Degree SL306 SL312 SL318 SL324 SL336 SL348Install the Ceiling Firestops Assemble the Chimney SectionsInstall the Attic Insulation Shield Double-check the Chimney AssemblySecure the Chimney Complete the Enclosure Chimney TerminationInstall the Termination Cap Install the Chimney Air Kit required in CanadaChase Top Installing an ST375 Square Termination Cap Accessories Junction Box InstallationGas Log/Lighter Provisions Gas Code, Ansi Z223.1Installation of Fan Shock RiskFinishing Hearth ExtensionFinishing Material MantelGlass Doors Combustible MaterialOperating Instructions General InformationOutside Air Clear Space Near the FireplaceFlue Damper FirescreenGrate Wood FuelFirewood MoistureStarting a Fire Troubleshooting Understanding Vent ProblemsDiagnostics and Problem Solving Diagnostic QuestionsSolutions Can’t get a good fire going. What am I doing wrong?fireplace burns the wood too fast. What can I do? Maintenance and Servicing the Fireplace Chimney Inspection/CleaningDisposal of Ashes Firebox RefractoryMaintenance Task List When cleaning glass doorClean Chimney FireFireplace Dimensions Reference Materials¨ B. Fireplace Components Catalog # DescriptionChimney Components Catalog #14-1/2 1829 mm 10-7/8 276 mm 406 mm 508 mm Minimum Base Dimensions 28 X 28 with 32 X 32 with 23 X Minimum Base Dimensions 26.5 X 28 with 34 X 34 withTR442 TR442 / 444 TV 20 xService Parts EM-415 SeriesDescription of Part EM-415 EM-415H Qty Herringbone Brick Refractory option available week 03/04This page intentionally left blank Warranty For Heat & GLO Fireplaces Limited WarrantyContact Information