Hearth and Home Technologies A42R, A36RH Install Termination Cap, ST375 Square Termination Cap

Page 33

D. Install Termination Cap

Install the chimney sections up through the chase enclo- sure.

Refer to termination cap instructions.

WARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and embers to escape.

NOTICE: Paint the termination cap with a rust-resistant paint to protect against the effects of corrosion on those parts exposed to the weather.

TR344 Round Termination Cap

TR342 Round Telescoping Termination Cap

Assemble

Termination

storm collar

Cap

around extended

 

 

 

 

 

termination cap

 

 

 

 

 

pipe

 

 

 

 

 

once cap is

 

 

 

 

 

installed.

 

 

 

Do NOT

 

 

 

 

 

 

 

 

block air

 

 

 

 

Caulk gaps between

 

 

 

holes

storm collar & pipe,

Storm

and storm collar

Collar

& chase top.

 

 

 

3 clip brackets.

 

 

 

Slip over chase collar

 

 

 

and attach with screws

 

 

 

 

provided.

Collar

 

 

 

 

 

2 in. (51 mm)

 

 

14 1/2 in. (368 mm)

Minimum Height

 

 

 

 

 

Maximum

 

 

 

 

 

Termination

Cap

Slip

storm collar

around chimney pipe

before termination cap pipe is snapped into the chimney pipe.

Caulk gaps between

Storm

storm collar & pipe,

Collar

and storm collar

 

& chase top.

 

Collar

 

2 in. (51 mm)

Chimney

Minimum Height

Pipe

 

Chase Top

 

Do NOT

block air holes

6 in. (153 mm) Minimum top of chase to top of chimney pipe

Chase Top

Chase

Chimney

Pipe

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Figure 9.5 Installing a TR342 Round Telescoping Termination Cap

ST375 Square Termination Cap

Chase

Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm).

Figure 9.4 Installing a TR344 Round Termination Cap

Termination Cap

Collar

2 in. (51 mm)

Minimum Height

Chase Top

Chimney

Pipe

Place waterproof caulk or sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

Flange

4 3/4 in. (121 mm)

Maximum

top of chase to top of

chimney section

Chase

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Figure 9.6 Installing an ST375 Square Termination Cap

Heatilator • A36R & A42R • 28376 • Rev AF • 11/08

33

Image 33
Contents Operation Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Fire RiskListing Label Information/Location GrateNumber Table of Contents Installer GuideUser Guide CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeatilator A36R & A42R 28376 Rev AF 11/08 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceHardwood vs Softwood Wood FuelMaintainance and Service Chimney Inspection/CleaningDisposal of Ashes Check Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededMm all configurations Fireplace Dimensions .A 1219 mm MinimumFraming & Clearances Select Fireplace LocationClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsThings to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Hood Wire Ties Install Outside Air KitSecure flex duct with metal tape, screws or wire ties Flexible Duct not suppliedMaintain minimum height of chimney above roof Chimney AssemblyHeight of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsInstall Chimney Air Kit Installing Ceiling FirestopsAssembling Chimney Sections Prepare Attic Insulation Shield Installing Attic Insulation ShieldComplete Installation Install FlashingCut out Hole in Roof Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST375 Square Termination Cap Install Termination CapTCT375 Terra Cotta Cap TS345/TS345P Square Termination CapShrouds Some shrouds require a radiation shield. Use where specifiedRadiation Shield Field Constructed ShroudsMailbox Style Shroud radiation shield required Finishing Hearth Extension= 1/k x inches of thickness HX3 or HX4 Hearth Ext or equivilent insulation Finishing Material305 mm Combustible MantelInstall Fan AccessoriesGas Log/Lighter Provision Wood Burning Inserts578 mm 10-1/2 222 mm 22-3/4165 mm 267 mm Dia 28376 Gas Knockout Rev Outside 23-3/8 Air 235 mm 594 mm 244 mm 219 mm 206 mm 108 mm 13-1/2 343 mmCatalog # Description Fireplace ComponentsCatalog # Chimney Components10-1/2 267 mm Effective Outside Height Diameter 10-1/2 121 mm 267 mm305 mm 27-3/8 24-5/8 695 mm 625 mm 305 mm 24-5/8 625 mm 787 mm10-7/8 276 mm A36R, A36RH Service PartsA42R, A42RH Contact Information

A36RH, A42RH, A36R, A42R specifications

Hearth and Home Technologies offers a distinguished range of fireplace products to cater to diverse consumer needs, focused on delivering warmth and style to any living space. Among their offerings, the A42R, A36R, A42RH, and A36RH models stand out, each equipped with advanced features and innovative technologies that enhance the overall user experience.

The A42R and A36R are designed specifically for those who appreciate the elegance of traditional fireplaces while also seeking the efficiency and convenience of modern technology. Both models feature a large viewing area, providing an impressive flame display that creates a captivating focal point in any room. The clean face design eliminates the need for a traditional mantel, allowing for more flexible installation options and a contemporary aesthetic that complements various interior styles.

One of the key characteristics of both the A42R and A36R is their advanced combustion technology, which promotes efficient fuel use while minimizing emissions. This ensures that customers can enjoy the comforting warmth of a fire without compromising air quality. Additionally, these models come equipped with a state-of-the-art heat distribution system, ensuring that warmth spreads evenly throughout the room.

The A42RH and A36RH models take the concept of efficiency further by incorporating a high-efficiency rating. With a focus on heat retention, these models are capable of generating substantial warmth that can be comfortably felt in larger spaces. The RH designation indicates a built-in blower system that maximizes heat output and ensures a cozy atmosphere during even the coldest months.

All four models feature easy-to-use controls, allowing homeowners to adjust heat output and flame levels to suit their preferences. This versatility sets them apart from traditional wood-burning fireplaces, offering a more user-friendly experience. Moreover, the fireplaces are engineered with durable materials and quality craftsmanship, ensuring a long-lasting investment for any household.

In summary, Hearth and Home Technologies’ A42R, A36R, A42RH, and A36RH models deliver a perfect blend of elegance, efficiency, and innovation. Their key features, including large viewing areas, advanced combustion technology, and effective heat distribution systems, make them ideal choices for homeowners looking to enhance their living spaces with the joy and comfort of a fireplace. Whether opting for the simpler A42R and A36R or the high-efficiency A42RH and A36RH, consumers can expect both style and functionality in their choice of Hearth and Home Technologies fireplaces.