9 Appliance Preparation

A. Install Outside Air Kit Damper Assembly

CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during installa- tion. Sheet metal edges are sharp.

WARNING! Risk of Fire/Asphyxiation. DO NOT draw out-

side combustion air from:

Wall, floor or ceiling cavity.

Enclosed space such as an attic or garage.

Close proximity to exhaust vents or chimneys.

Fumes or odor may result.

The outside air kit can only be installed on the left side of the appliance.

Refer to the installation instructions provided with the kit.

Figure 9.1 Outside Air Kit Installation

B. Gas and Electrical Connections

If applicable, ensure that gas and electrical connections are installed at this time. Refer to Sections 11 (Gas Infor- mation) and 12 (Electrical Information).

C. Secure and Level the Appliance

WARNING! Risk of Fire! Prevent contact with:

Sagging or loose insulation

Insulation backing or plastic

Framing and other combustible materials

Block openings into the chase to prevent entry of blown-in insulation. Make sure insulation and other materials are secured.

DO NOT notch the framing around the appliance standoffs.

Failure to maintain air space clearance may cause overheating and fire.

The diagram shows how to properly position, level, and secure the appliance (see Figure 9.2). Nailing tabs are provided to secure the appliance to the framing members.

Bend out nailing tabs on each side.

Place the appliance into position.

Keep nailing tabs flush with the framing.

Level the appliance from side to side and front to back.

Shim the appliance as necessary. It is acceptable to use wood shims underneath the appliance.

Secure the appliance to the framing by using nails or screws through the nailing tabs.

Secure the appliance to the floor by inserting two screws through the bottom front of the appliance.

Nailing Tabs (both sides)

Figure 9.2 Proper Positioning and Securing of Appliance

Heatilator • BCBV36 • 4008-033 • Rev F • 12/08

23

Image 23
Contents What to do if you smell gas Installation and OperationModels Vent Gas ApplianceHomeowner Reference Information CongratulationsUser Guide Table of ContentsInstaller Guide Warranty Warranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions Outside Air optional Remote Controls, Wall Controls and Wall SwitchesClear Space Decorative Doors and FrontsLighting Instructions IPI For Your Safety Read Before LightingPilot LightingInstructions Standing After Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningBurner Ignition and Operation LogsFirebox Control Compartment and Firebox TopTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Negative Pressure Construct the Appliance Chase Framing dimensions are the same with or without outside airFraming and Clearances Select Appliance LocationClearances to Combustibles ClearancesMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Vent Termination Minimum Clearances Termination LocationsVent System Configuration Vent Information and DiagramsVent Guidelines Vertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingSecure and Level the Appliance Install Outside Air Kit Damper AssemblyAppliance Preparation Gas and Electrical ConnectionsSecure Vent Sections Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsStanding Pilot Ignition System Wiring Intellifire Ignition System WiringGAS Electrical Service and RepairPrepare Junction Box Bracket Junction Box InstallationFacing Material FinishingAppliance Setup Place the Rockwool Place the Vermiculite Log Removal/ReplacementHood Air Shutter SettingStanding Pilot Ignition System TroubleshootingShould be Placed in this Opening Intellifire Ignition System Symptom Possible Cause Corrective ActionPilot lights but continues Shorted or loose connection Reference Materials Appliance Dimension DiagramBCBV36 Service Parts ListParts List ServiceBCBV36I Description Commnets Part Number Service Parts ListSMART-BATT-HTL Optional ComponentsThis page intentionally left blank Contact Information

BCBV36I, BCBV36 specifications

Hearth and Home Technologies is a leader in delivering innovative heating solutions, and their BCBV36 and BCBV36I models demonstrate this commitment to quality and performance. These versatile fireplaces are designed to provide warmth, ambiance, and a modern aesthetic that complements various home styles.

The BCBV36 and BCBV36I models are built with efficiency and functionality in mind. They feature a clean-burning, vented gas design that produces realistic flames while maximizing heat output. With an impressive heating capacity, these fireplaces can effectively warm large living spaces, making them an ideal choice for homeowners looking to enhance their comfort and ambiance during the colder months.

One of the standout characteristics of the BCBV36 and BCBV36I is their customizable appearance. These models come with several decorative options, allowing users to choose from various logs, stones, and glass media to create the perfect centerpiece for their living area. The sleek design of the fireplace ensures that it fits seamlessly into any room, while the large viewing area offers an unobstructed view of the flames.

In terms of technology, both models are equipped with advanced electronic ignition systems for ease of use and reliability. The user-friendly control panel allows homeowners to adjust the flame height and heat output conveniently, enhancing the overall user experience. Additionally, the fireplaces can be integrated with remote control options for added convenience.

Safety is a critical aspect of any heating solution, and the BCBV36 and BCBV36I incorporate several features to ensure peace of mind. The built-in safety shut-off system eliminates risks associated with overheating while the heat exchanger design maximizes warmth while minimizing exhaust emissions.

Maintenance is also simplified with these models. The easy-to-remove glass fronts make it straightforward for homeowners to clean and maintain the fireplace, ensuring it remains a stunning focal point in the home.

In summary, the Hearth and Home Technologies BCBV36 and BCBV36I offer an exceptional blend of style, efficiency, and safety. With modern designs, customizable options, and advanced technology, these fireplaces are a fantastic investment for anyone looking to enhance their home’s atmosphere and heating capabilities. These qualities make them a top choice in the realm of residential gas fireplaces.