Hearth and Home Technologies BCBV36I owner manual Troubleshooting, Standing Pilot Ignition System

Page 33

15 Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician. Con- tact your dealer to arrange a service call by a qualified service technician.

A. Standing Pilot Ignition System

Symptom

Possible Causes

Corrective Action

 

 

 

1. After repeated triggering

A. No gas or low gas pressure.

Check the remote shut-off valves from the appliance. Usually, there

of the red or black piezo

 

is a valve near the gas main. There can be more than one valve

ignitor button, the spark

 

between the appliance and the main.

ignitor will not light the

 

 

B. No LP in tank.

Check the LP (propane) tank. You may be out of fuel.

pilot. Check for spark.

 

 

C. Ignitor.

Check the spark at the electrode and pilot. If no spark and electrode

 

 

 

wire is properly connected, replace the ignitor. Verify that there is no

 

 

short in electrode wire.

 

D. Pilot or misaligned electrode

Using match, light the pilot. If the pilot lights, turn off the pilot and

 

(spark at electrode).

trigger the piezo ignitor button again. If the pilot lights, an improper

 

 

gas/air mixture caused the bad lighting and a longer purge period

 

 

is recommended. If the pilot will not light, ensure the gap at the

 

 

electrode and pilot is one-eighth inch to have a strong spark. If the

 

 

gap is OK, replace the pilot.

 

 

 

2. The pilot will not stay lit

A. Thermocouple.

Check that the pilot flame impinges on the thermocouple. Adjust the

after carefully following the

 

pilot for proper flame impingement.

lighting instructions.

 

Ensure that the thermocouple connection at the gas valve is fully

 

 

 

 

inserted and tight (hand tighten plus 1/4 turn).

 

 

Verify proper voltage output from the thermocouple to the valve.

 

 

Place one millivolt meter lead wire on the thermocouple copper lead.

 

 

Place the second lead wire on the solder button on the back of the

 

 

valve (blue wire). Start the pilot and hold the valve knob in. The

 

 

millivolt reading should read 8-16 millivolts. If millivolt reading is less

 

 

than 8 millivolts, replace thermocouple.

 

 

 

 

B. Improper gas inlet pressure.

Natural gas should be 5-7 in. w.c. LP should be 11-14 in. w.c. Verify

 

 

pressure with manometer.

 

C. Valve.

If the thermocouple is producing 8-16 millivolts, replace control valve.

 

 

 

3. The pilot is burning, there

A. On/off switch or wires

Check the ON/OFF switch and wires for proper connections. Place

is no burner flame, the

defective.

the jumper wires across the terminals at the ON/OFF switch. If the

valve knob is in the ON

 

burner comes on, replace the ON/OFF switch. If the switch is OK,

position, and the ON/OFF

 

place the jumper wires across the ON/OFF switch wires at the gas

switch is in the ON

 

valve. If the burner comes on, the wires are faulty or connections are

position.

 

bad.

 

 

 

 

B. Thermopile may not be

Check that the pilot flame impinges thermopile properly.

 

generating sufficient

 

 

Be sure the wire connections from the thermopile at the gas valve

 

millivoltage.

 

terminals are tight and that the thermopile is fully inserted into the

 

 

 

 

pilot bracket.

 

 

Check the thermopile with a millivolt meter. Take the reading at

 

 

TH-TP&TP terminals of the gas valve. The meter should read 350

 

 

millivolts minimum, while holding the valve knob depressed in the

 

 

pilot position, with the pilot lit, and the ON/OFF switch in the OFF

 

 

position. Replace the thermopile if the reading is below the specified

 

 

minimum.

 

 

With the pilot in the ON position, disconnect the thermopile leads

 

 

from the valve. Take a reading at the thermopile leads. The reading

 

 

should be 350 millivolts minimum. Replace the thermopile if the

 

 

reading is below the minimum.

 

 

 

Heatilator • BCBV36 • 4008-033 • Rev F • 12/08

33

Image 33
Contents Models Installation and OperationVent Gas Appliance What to do if you smell gasHomeowner Reference Information CongratulationsTable of Contents Installer GuideUser Guide Warranty Warranty Listing and Code Approvals Gas Fireplace Safety Operating InstructionsYour Fireplace Clear Space Remote Controls, Wall Controls and Wall SwitchesDecorative Doors and Fronts Outside Air optionalLighting Instructions IPI For Your Safety Read Before LightingLighting Instructions StandingPilot Frequently Asked Questions Initial Break-in ProcedureAfter Fireplace is Lit Maintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlFirebox LogsControl Compartment and Firebox Top Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Negative Pressure Framing and Clearances Framing dimensions are the same with or without outside airSelect Appliance Location Construct the Appliance ChaseClearances to Combustibles ClearancesMantel and Wall Projections MantelsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsVent Information and Diagrams Vent GuidelinesVent System Configuration Pipe Clearances to Combustibles Vent Clearances and FramingWall and Ceiling Penetration Framing Vertical Penetration FramingAppliance Preparation Install Outside Air Kit Damper AssemblyGas and Electrical Connections Secure and Level the ApplianceAssembly of Vent Sections Installing Vent PipeInstall Attic Insulation Shield Secure Vent SectionsFuel Conversion Gas InformationGas Pressure Gas ConnectionStanding Pilot Ignition System Wiring Wiring RequirementsIntellifire Ignition System Wiring Optional Accessories RequirementsGAS Electrical Service and RepairPrepare Junction Box Bracket Junction Box InstallationFacing Material FinishingAppliance Setup Place the Rockwool Place the Vermiculite Log Removal/ReplacementHood Air Shutter SettingStanding Pilot Ignition System TroubleshootingShould be Placed in this Opening Intellifire Ignition System Symptom Possible Cause Corrective ActionPilot lights but continues Shorted or loose connection Reference Materials Appliance Dimension DiagramBCBV36 Service Parts ListParts List ServiceBCBV36I Description Commnets Part Number Service Parts ListSMART-BATT-HTL Optional ComponentsThis page intentionally left blank Contact Information

BCBV36I, BCBV36 specifications

Hearth and Home Technologies is a leader in delivering innovative heating solutions, and their BCBV36 and BCBV36I models demonstrate this commitment to quality and performance. These versatile fireplaces are designed to provide warmth, ambiance, and a modern aesthetic that complements various home styles.

The BCBV36 and BCBV36I models are built with efficiency and functionality in mind. They feature a clean-burning, vented gas design that produces realistic flames while maximizing heat output. With an impressive heating capacity, these fireplaces can effectively warm large living spaces, making them an ideal choice for homeowners looking to enhance their comfort and ambiance during the colder months.

One of the standout characteristics of the BCBV36 and BCBV36I is their customizable appearance. These models come with several decorative options, allowing users to choose from various logs, stones, and glass media to create the perfect centerpiece for their living area. The sleek design of the fireplace ensures that it fits seamlessly into any room, while the large viewing area offers an unobstructed view of the flames.

In terms of technology, both models are equipped with advanced electronic ignition systems for ease of use and reliability. The user-friendly control panel allows homeowners to adjust the flame height and heat output conveniently, enhancing the overall user experience. Additionally, the fireplaces can be integrated with remote control options for added convenience.

Safety is a critical aspect of any heating solution, and the BCBV36 and BCBV36I incorporate several features to ensure peace of mind. The built-in safety shut-off system eliminates risks associated with overheating while the heat exchanger design maximizes warmth while minimizing exhaust emissions.

Maintenance is also simplified with these models. The easy-to-remove glass fronts make it straightforward for homeowners to clean and maintain the fireplace, ensuring it remains a stunning focal point in the home.

In summary, the Hearth and Home Technologies BCBV36 and BCBV36I offer an exceptional blend of style, efficiency, and safety. With modern designs, customizable options, and advanced technology, these fireplaces are a fantastic investment for anyone looking to enhance their home’s atmosphere and heating capabilities. These qualities make them a top choice in the realm of residential gas fireplaces.