Hearth and Home Technologies BIR42 owner manual Locating your Fireplace & Chimney

Page 16

E. Locating your Fireplace & Chimney

Location of the fireplace and chimney will affect perfor- mance.

Install within the warm air space enclosed by the building envelope. This helps to produce more draft, especially during lighting and die-down of the fire.

Penetrate the highest part of the roof. This minimizes the effects of wind loading.

Locate termination cap away from trees, adjacent structures, uneven roof lines and other obstructions.

Minimize the use of chimney offsets.

Consider the fireplace location relative to floor and ceiling and attic joists.

Take into consideration the termination requirements in

Section 8 and Section 9.

NOTICE: Locating the fireplace in an area of considerable air movement can cause intermittent smoke spillage from fireplace. Do not locate fireplace near

frequently open doors

central heat outlets or returns

DO NOT install in a basement.

 

 

 

 

Recommended Location:

 

 

 

 

Recommended Location:

• Above peak

 

 

 

 

 

Above peak

• Inside heated space

 

 

 

 

 

 

Marginal Location:

Marginal Location:

 

 

 

 

Wind loading possible

 

 

 

 

• Below peak

 

 

 

Location NOT recommended:

 

 

 

 

 

 

Not the highest point of the roof

 

 

 

 

 

 

Wind loading possible

 

 

 

 

 

 

 

 

 

 

 

 

Location NOT recommended:

 

 

 

 

 

 

Too close to tree

 

 

 

Recommended:

 

 

Below adjacent structure

 

 

 

• Insulated exterior chase

 

Lower roof line

 

 

 

in cooler climates

 

Avoid outside wall

 

Windward

 

 

 

 

 

 

 

 

 

 

 

 

 

Leeward

 

 

 

 

Multi-level Roofs

 

 

 

Figure 5.1 Recommended Chimney Locations

 

 

 

 

16

Heatilator • Birmingham BIR42 • 4059-308 Rev F • 11/08

 

Image 16
Contents Hot screen/mesh and glass doors will cause burns Fire RiskGrate Listing Label Information/LocationNumber Table of Contents Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHeatilator Birmingham BIR42 4059-308 F 11/08 Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsOperating Instructions Your FireplaceSeasoned Wood Starting a FireGrate FirescreenGlass Doors Vented Gas Log Sets & Gas Log LightersOptional Components Clear SpaceWood Fuel Hardwood vs SoftwoodChimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Glass Cleaning Check Firebox Molded Brick PanelInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemDraft Design and Installation ConsiderationsNegative Pressure Locating your Fireplace & Chimney Recommended Chimney LocationsInspect Fireplace and Components Tools and Supplies NeededTypical Fireplace Components Framing & Clearances Select Fireplace LocationClearances Air Space ClearancesSidewalls/Surrounds Frame the FireplaceInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsYES Install Outside Air Kit Outside Air InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleAssemble Chimney Sections Assembling Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield Prepare Attic Insulation ShieldInstall Flashing Complete InstallationCut Out Hole in Roof Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST1175 Square Termination CapTCT1175 Terra Cotta Cap Radiation Shield ShroudsField Constructed Shrouds Mailbox Style Shroud radiation shield required Installation of Molded Brick Panel Install Hearth Molded Brick PanelInstall Side Molded Brick Panel/Traditional Install Back Molded Brick Panel/TraditionalInstall Side Molded Brick Panel Herring- bone Install Back Molded Brick Panel Herring- boneInstall Mortar Install ScreensHearth Extension Finishing= 1/k x inches of thickness Noncombustible Framing MaterialEquivalent insulation Finishing MaterialsNon-combustible Sealant Finishing Material Noncombustible FacingCombustible Mantel Mantel, Adding Extra Support 14 Secure to FramingBrick Front Accessories Gas Log/Lighter ProvisionWood Burning Inserts Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsID6 Insulated Duct .4 mm i.d 1067 mm UD6 Uninsulated Duct Chimney Components Catalog #15-1/4 387 mm 31-3/4 806 mm 34-5/8 879 mm CT56 Chase Top Service PartsContact Information