Service Parts

BIR42

 

Service Parts Diagram

Beginning Manufacturing Date: April 2008

 

42 in. Woodburning Fireplace

Ending Manufacturing Date: Active

 

Service Parts

 

BIR42

 

Service Parts List

Beginning Manufacturing Date: April 2008

 

42 in. Woodburning Fireplace

 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or

Stocked

replacement parts for your appliance please provide model number and serial number.

All parts listed in this manual may be ordered from an authorized dealer.

 

at Depot

ITEM

DESCRIPTION

SERIAL #

PART NUMBER

D. Service

Heatilator • Birmingham BIR42 •

7

8

9

1 2

3

4

5

6

11

10

1

Transition Assembly

 

4059-044

N

2

Outer Transiton Assembly

 

24377

N

3

Inner Transiton Collar

 

4059-148

N

4

Damper Blade Assembly

 

4059-030

N

5

Damper Control

 

35159

N

6

Outside Air Collar Assembly

Qty 2 req

4059-037

N

7

OA Door

Qty 2 req

4059-049

N

8

Screen Rod

Qty 2 req

4059-312

Y

 

Screen Rod Clips

Qty 2 req

4059-111

N

9

Firescreen Assembly

Qty 2 req

4059-028

Y

10

Grate Assembly

 

GR29

N

11

Hearth Molded Brick Panel

 

4059-033

N

Traditional Molded Brick Panel

 

 

 

12

Lower Left Panel

 

4059-350

N

13

Upper Left Panel

 

4059-351

N

14

Lower Right Panel

 

4059-352

N

15

Upper Right Panel

 

4059-353

N

16

Lower Rear Panel

 

4059-354

N

17

Upper Rear Panel

 

4059-355

N

Herringbone Molded Brick Panel

 

 

 

18

Lower Left Panel

 

4059-357

N

19

Upper Left Panel

 

4059-358

N

20

Lower Right Panel

 

4059-359

N

21

Upper Right Panel

 

4059-360

N

22

Lower Rear Panel

 

4059-361

N

Parts

4059-308 F • 11/08

Traditional Molded Brick Panel

17

13

16

15

12

14

Herringbone Molded Brick Panel

19

23

 

22

18

 

 

21

11

20

23

Upper Rear Panel

 

4059-362

N

 

 

 

 

 

 

Refractory Fastener Pack

 

 

 

 

Contains:25 #6 X 1 1/2" Panhead screw, 3/32" Drill Bit, 17

 

4059-043

N

 

T- Brackets, 2 Y-Brackets, 6 Clips,

 

 

 

 

 

 

 

 

 

Mortar

25 LB Box

4059-316

N

 

 

 

 

 

 

 

 

 

 

 

Outside Air Hood

Qty 2 req

4059-051

N

11

Part numbers on following page.

05/08

05/08

55

Image 55
Contents Fire Risk Hot screen/mesh and glass doors will cause burnsGrate Listing Label Information/LocationNumber Table of Contents CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeatilator Birmingham BIR42 4059-308 F 11/08 Combustible Materials Listing and Code ApprovalsAppliance Certification Non-Combustible MaterialsYour Fireplace Operating InstructionsFirescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsHardwood vs Softwood Wood FuelChimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Frequency As desired Glass CleaningCheck Firebox Molded Brick Panel Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDraft Design and Installation ConsiderationsNegative Pressure Recommended Chimney Locations Locating your Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededTypical Fireplace Components Select Fireplace Location Framing & ClearancesAir Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsPlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceYES Outside Air Installation Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssembling Chimney Sections Assemble Chimney SectionsInstalling the Ceiling Firestop Install Ceiling FirestopsPrepare Attic Insulation Shield Install Attic Insulation ShieldInstall Flashing Complete InstallationCut Out Hole in Roof Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Radiation Shield ShroudsField Constructed Shrouds Mailbox Style Shroud radiation shield required Install Back Molded Brick Panel/Traditional Installation of Molded Brick PanelInstall Hearth Molded Brick Panel Install Side Molded Brick Panel/TraditionalInstall Back Molded Brick Panel Herring- bone Install Side Molded Brick Panel Herring- boneInstall Screens Install MortarHearth Extension Finishing= 1/k x inches of thickness Finishing Materials NoncombustibleFraming Material Equivalent insulationNon-combustible Sealant Noncombustible Facing Finishing MaterialCombustible Mantel 14 Secure to Framing Mantel, Adding Extra SupportBrick Front Gas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Fireplace DimensionsID6 Insulated Duct .4 mm i.d 1067 mm UD6 Uninsulated Duct Catalog # Chimney Components15-1/4 387 mm 31-3/4 806 mm 34-5/8 879 mm CT56 Chase Top Parts ServiceContact Information