Hearth and Home Technologies PIER-40 Install Outside Air Kit, AK17 Installation BAY-40

Page 23

E. Install Outside Air Kit

Keep duct runs short and straight to minimize restriction. A small dip is acceptable for a cold air trap.

The outside air kit must be installed on the left hand side of the fireplace.

Locate the outside air hood in a clear area, preferably into prevailing wind during the heating season. Refer to Figure 5.2.

Install as shown in Figures 7.3 - 7.5.

The air duct may be run vertically.

The outside air hood must be at least 3 ft (.91 m) below the top of the uppermost chimney section.

CAUTION! Risk of Fire or Asphyxiation! DO NOT draw outside combustion air from wall, floor or ceiling cavity, or enclosed spaces such as an attic or garage.

DO NOT place outside air hood close to exhaust vents or chimneys. Fumes or odor could be drawn into the room through the fireplace.

Locate outside air inlet to prevent blockage from leaves, snow/ice, or other debris. Blockages could cause combustion air starvation.

Flexible Duct (not supplied)

 

 

Outside Air

Outside Air

 

Plate

 

Assembly

Hood

2 Wire Ties

 

Hearth & Home Technologies Inc recommends using UL181 Class 0 or Class I rigid or flexible ducting.

Secure flex duct with metal tape, screws or wire ties.

Figure 7.5 Typical Outside Air Installation (BAY-40 will be in- stalled from the bottom of the fireplace)

AK17 Installation (BAY-40)

Remove the cover plate from the bottom of the fireplace and replace it with outside air plate assembly using existing screws.

Mark and cut out a 4 1/2 in. (114 mm) diameter hole in the building side for air entry. This hole should allow for some framing (two sides) so the outside air hood assembly may be nailed into position, flush with building’s outside.

Secure flexible duct (not supplied) to the plate assembly.

Feed duct through hole to the outside, fasten to the hood assembly.

Fasten outside air hood assembly to the structure with screws.

Note: To guard against significant cold air infiltration through duct or other parts of system, check for light leaks with a flashlight and seal these with duct tape and/or insulation.

AK14/AK18 Installation (PIER-40)

The hinge will be toward the front of the fireplace.

Insert the narrow end of the handle into the upper slot.

Pivot the handle in the slot toward the hinge.

Remove the cover plate or knockout from the side of the fireplace and discard. Remove the semi-perforated piece of insulation covering the opening (insulated fireplaces only).

Partly open the air kit door and insert the handle into the appropriate hole in the side column of the fireplace. The hinge on the door assembly should be located toward the front of the fireplace. If the hinge and the handle are not positioned in this manner, the door will not function correctly.

Attach the door assembly to the fireplace using the screws provided.

Check operation by pulling the handle out to open and pushing it in to close.

Mark and cut out a 4 1/2 in. (114 mm) hole in the building side for air entry. This hole should allow some framing (two sides) so the 4 in. (102 mm) diameter inlet tube assembly may be fastened properly.

Assemble flexible duct (not supplied) between the door assembly and the inlet tube assembly. Secure it in position with the supplied wire ties.

Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08

23

Image 23
Contents Hot screen/mesh and glass doors will cause burns Fire RiskNumber Model Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeat & Glo BAY-40, PIER-40 34977 Rev W 11/08 Combustible Materials Listing and Code ApprovalsAppliance Certification Non-Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Firescreen Seasoned WoodStarting a Fire GrateVented Gas Log Sets & Gas Log Lighters Glass DoorsOutside Air optional Optional ComponentsHardwood vs Softwood Wood FuelDisposal of Ashes Maintainance and ServiceChimney Inspection/Cleaning Frequency As desired Glass CleaningCheck Firebox Refractory Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Select Fireplace Location Framing & ClearancesAir Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsPlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceFt min. from top of uppermost chimney section to air inlet AK17 Installation BAY-40 Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling Firestops330 mm Install Attic Insulation ShieldCut out Hole in Roof Complete InstallationInstall Flashing Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Field Constructed Shrouds ShroudsRadiation Shield Mailbox Style Shroud radiation shield required = 1/k x inches of thickness FinishingHearth Extension From opening In. Micore or equivilent insulation Finishing MaterialFlush Front Combustible MantelGas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Fireplace Dimensions13 mm Catalog # Chimney Components15-1/4 387 mm 15-3/4 400 mm Parts ServicePIER-40 Service PartsThis page intentionally left blank This page intentionally left blank Do not Discard this Manual

PIER-40, BAY-40 specifications

Hearth and Home Technologies has been a leader in the realm of heating solutions, and their innovative products like the BAY-40 and PIER-40 exemplify the cutting-edge technology and design that the brand is known for. These models reflect the shift towards more efficient, environmentally friendly heating options without sacrificing aesthetic appeal or user comfort.

The BAY-40 is a versatile direct vent gas fireplace that offers a stunning flame presentation, making it a focal point in any room. With a heat output of up to 40,000 BTU, it provides ample warmth while maintaining efficiency. This model features an array of customizability options, allowing users to select from various decorative media such as glass or logs to personalize their fireplace. The BAY-40 is also designed for straightforward installation, often requiring less venting compared to traditional fireplaces, making it a practical choice for both new builds and renovations.

On the other hand, the PIER-40 is a premium linear gas fireplace that emphasizes a modern aesthetic. It can be installed indoors or outdoors, providing flexibility for users wanting to create seamless transitions between spaces. The PIER-40 delivers an impressive heat output and is engineered with advanced technology to enhance efficiency and reduce environmental impact. With optional features like LED lighting and customizable front panels, the PIER-40 can cater to various design preferences and settings, from cozy interiors to stylish outdoor living areas.

Both models incorporate innovative technologies such as electronic ignition systems and adjustable flame settings, allowing users to tailor their experience. They also prioritize safety, featuring glass doors that prevent direct contact with flames and heat. Furthermore, they are built with durable materials designed to withstand the rigors of regular use.

In terms of energy efficiency, both the BAY-40 and PIER-40 meet stringent guidelines, often exceeding standard requirements. This not only reduces utility bills for homeowners but also aligns with a growing emphasis on sustainable living.

Overall, Hearth and Home Technologies' BAY-40 and PIER-40 fireplaces represent a commitment to quality, innovation, and user satisfaction. With their blend of modern design, advanced engineering, and customizable features, they are excellent choices for anyone looking to add warmth and style to their home or outdoor space while keeping efficiency and environmental considerations in mind.