F. Install Attic Insulation Shield

WARNING! Risk of Fire! You MUST install an attic insu- lation shield when there is any possibility of insulation or other combustible material coming into contact with the chimney.

DO NOT pack insulation between the chimney and the attic insulation shield.

Failure to keep insulation and other materials away from chimney pipe could cause fire.

DO NOT offset chimney inside insulation shield.

Installation of a ceiling firestop is required

Refer to Figures 8.6 - 8.8.

Roll the shield (around the chimney if already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on top).

Insert three screws into the matching holes to form a tube.

Bend three tabs on the bottom of the tube inward to 90° to maintain chimney air space (refer to Figure 8.6).

Rest the insulation shield on the ceiling firestop below.

Bend the three short tabs at the top of the shield inward to 90° to maintain the 2 in. (51 mm) air space from the chimney.

Bend the remaining top tabs to just meet the pipe.

If you wish to make a custom shield or barrier, follow these guidelines:

Metal is preferred, although any material stiff enough to hold back the insulation can be used.

WARNING! Risk of Fire! Use of cardboard or other materials that can deflect under humidity or other envi- ronmental conditions is not recommended.

The shield or barrier must be tall enough to extend above the insulation and prevent blown-in insulation from spilling into the cavity.

Maintain specified air spaces around chimney.

Check instructions and local codes for further details.

 

 

 

 

Bend remaining tabs

 

 

 

 

to rest against pipe to

Bend

 

inward

prevent insulation

90°

 

from falling in.

 

 

 

 

 

Insert three

 

 

 

 

screws

3 in. (76 mm) overlap

Figure 8.6 Prepare Attic Insulation Shield

 

 

Tabs bent in to

 

Pipe

rest against pipe

 

 

 

 

Attic Insulation Shield

 

 

17 in. (432 mm)

 

6 Tabs bent

diameter

 

in 90°

Ceiling Firestop

 

 

Insulation

Pipe

Insulation

13 in.

(330 mm)

Figure 8.7 Install Attic Insulation Shield (firestop above ceiling)

 

 

Tabs bent in to

 

 

rest against pipe

 

Pipe

 

 

 

Attic Insulation Shield

 

 

17 in. (432 mm)

 

 

diameter

 

6 Tabs bent

 

 

in 90°

 

Insulation

 

Insulation

13 in.

Pipe

Ceiling Firestop

(330 mm)

 

 

Figure 8.8 Install Attic Insulation Shield (firestop below ceiling)

Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08

29

Image 29
Contents Hot screen/mesh and glass doors will cause burns Fire RiskNumber Model Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeat & Glo BAY-40, PIER-40 34977 Rev W 11/08 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Starting a Fire Seasoned WoodGrate FirescreenOutside Air optional Glass DoorsOptional Components Vented Gas Log Sets & Gas Log LightersHardwood vs Softwood Wood FuelDisposal of Ashes Maintainance and ServiceChimney Inspection/Cleaning Check Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Select Fireplace Location Framing & ClearancesAir Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsThings to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet AK17 Installation BAY-40 Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling Firestops330 mm Install Attic Insulation ShieldCut out Hole in Roof Complete InstallationInstall Flashing Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Field Constructed Shrouds ShroudsRadiation Shield Mailbox Style Shroud radiation shield required = 1/k x inches of thickness FinishingHearth Extension From opening In. Micore or equivilent insulation Finishing MaterialFlush Front Combustible MantelGas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace Dimensions13 mm Catalog # Chimney Components15-1/4 387 mm 15-3/4 400 mm Parts ServicePIER-40 Service PartsThis page intentionally left blank This page intentionally left blank Do not Discard this Manual

PIER-40, BAY-40 specifications

Hearth and Home Technologies has been a leader in the realm of heating solutions, and their innovative products like the BAY-40 and PIER-40 exemplify the cutting-edge technology and design that the brand is known for. These models reflect the shift towards more efficient, environmentally friendly heating options without sacrificing aesthetic appeal or user comfort.

The BAY-40 is a versatile direct vent gas fireplace that offers a stunning flame presentation, making it a focal point in any room. With a heat output of up to 40,000 BTU, it provides ample warmth while maintaining efficiency. This model features an array of customizability options, allowing users to select from various decorative media such as glass or logs to personalize their fireplace. The BAY-40 is also designed for straightforward installation, often requiring less venting compared to traditional fireplaces, making it a practical choice for both new builds and renovations.

On the other hand, the PIER-40 is a premium linear gas fireplace that emphasizes a modern aesthetic. It can be installed indoors or outdoors, providing flexibility for users wanting to create seamless transitions between spaces. The PIER-40 delivers an impressive heat output and is engineered with advanced technology to enhance efficiency and reduce environmental impact. With optional features like LED lighting and customizable front panels, the PIER-40 can cater to various design preferences and settings, from cozy interiors to stylish outdoor living areas.

Both models incorporate innovative technologies such as electronic ignition systems and adjustable flame settings, allowing users to tailor their experience. They also prioritize safety, featuring glass doors that prevent direct contact with flames and heat. Furthermore, they are built with durable materials designed to withstand the rigors of regular use.

In terms of energy efficiency, both the BAY-40 and PIER-40 meet stringent guidelines, often exceeding standard requirements. This not only reduces utility bills for homeowners but also aligns with a growing emphasis on sustainable living.

Overall, Hearth and Home Technologies' BAY-40 and PIER-40 fireplaces represent a commitment to quality, innovation, and user satisfaction. With their blend of modern design, advanced engineering, and customizable features, they are excellent choices for anyone looking to add warmth and style to their home or outdoor space while keeping efficiency and environmental considerations in mind.