Hearth and Home Technologies BAY-40 Install Termination Cap, ST1175 Square Termination Cap

Page 34

D. Install Termination Cap

Install the chimney sections up through the chase enclo- sure.

Refer to termination cap instructions.

WARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and embers to escape.

NOTICE: Paint the termination cap with a rust-resistant paint to protect against the effects of corrosion on those parts exposed to the weather.

TR11 Round Termination Cap

TR11T Round Telescoping Termination Cap

Assemble

Termination

storm collar

Cap

around extended

 

 

 

 

 

termination cap

 

 

 

 

 

pipe

 

 

 

 

 

once cap is

 

 

 

 

 

installed.

 

 

 

Do NOT

 

 

 

 

 

 

 

 

block air

 

 

 

 

Caulk gaps between

 

 

 

holes

storm collar & pipe,

Storm

and storm collar

Collar

& chase top.

 

 

 

3 clip brackets.

 

 

 

Slip over chase collar

 

 

 

and attach with screws

 

 

 

 

provided.

Collar

 

 

 

 

 

2 in. (51 mm)

 

 

14 1/2 in. (368 mm)

Minimum Height

 

 

 

 

 

Maximum

 

 

 

 

 

Termination

Cap

Slip

storm collar

around chimney pipe

before termination cap pipe is snapped into the chimney pipe.

Caulk gaps between

Storm

storm collar & pipe,

Collar

and storm collar

 

& chase top.

 

Collar

 

2 in. (51 mm)

Chimney

Minimum Height

Pipe

 

Chase Top

 

Do NOT

block air holes

6 in. (153 mm) Minimum top of chase to top of chimney pipe

Chase Top

Chase

Chimney

Pipe

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Figure 9.5 Installing a TR11T Round Telescoping Termination Cap

ST1175 Square Termination Cap

Chase

Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm).

Figure 9.4 Installing a TR11 Round Termination Cap

Termination Cap

Collar

2 in. (51 mm)

Minimum Height

Chase Top

Chimney

Pipe

Place waterproof caulk or sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

Flange

4 3/4 in. (121 mm)

Maximum

top of chase to top of

chimney section

Chase

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Figure 9.6 Installing an ST1175 Square Termination Cap

34

Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08

Image 34
Contents Fire Risk Hot screen/mesh and glass doors will cause burnsGrate Listing Label Information/LocationNumber Model Installer Guide Table of ContentsUser Guide Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHeat & Glo BAY-40, PIER-40 34977 Rev W 11/08 Non-Combustible Materials Listing and Code ApprovalsAppliance Certification Combustible MaterialsYour Fireplace Operating InstructionsHot glass will cause burns Grate Seasoned WoodStarting a Fire FirescreenOptional Components Glass DoorsOutside Air optional Vented Gas Log Sets & Gas Log LightersWood Fuel Hardwood vs SoftwoodChimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Inspect Grate Glass CleaningCheck Firebox Refractory Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemDraft Design and Installation ConsiderationsNegative Pressure Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsFireplace System Requirements Tools and Supplies NeededInspect Fireplace and Components Framing & Clearances Select Fireplace LocationClearances Air Space ClearancesSidewalls/Surrounds Frame the FireplacePosition the Fireplace Installation of FireplaceThings to Consider Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Install Outside Air Kit AK17 Installation BAY-40Chimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield 330 mmInstall Flashing Complete InstallationCut out Hole in Roof Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST1175 Square Termination CapTCT1175 Terra Cotta Cap Radiation Shield ShroudsField Constructed Shrouds Mailbox Style Shroud radiation shield required Hearth Extension Finishing= 1/k x inches of thickness From opening Finishing Material In. Micore or equivilent insulationCombustible Mantel Flush FrontWood Burning Inserts AccessoriesGas Log/Lighter Provision Gas Code, Ansi Z223.1Fireplace Dimensions Reference Materials13 mm Chimney Components Catalog #15-1/4 387 mm 15-3/4 400 mm Service PartsService Parts PIER-40This page intentionally left blank This page intentionally left blank Do not Discard this Manual

PIER-40, BAY-40 specifications

Hearth and Home Technologies has been a leader in the realm of heating solutions, and their innovative products like the BAY-40 and PIER-40 exemplify the cutting-edge technology and design that the brand is known for. These models reflect the shift towards more efficient, environmentally friendly heating options without sacrificing aesthetic appeal or user comfort.

The BAY-40 is a versatile direct vent gas fireplace that offers a stunning flame presentation, making it a focal point in any room. With a heat output of up to 40,000 BTU, it provides ample warmth while maintaining efficiency. This model features an array of customizability options, allowing users to select from various decorative media such as glass or logs to personalize their fireplace. The BAY-40 is also designed for straightforward installation, often requiring less venting compared to traditional fireplaces, making it a practical choice for both new builds and renovations.

On the other hand, the PIER-40 is a premium linear gas fireplace that emphasizes a modern aesthetic. It can be installed indoors or outdoors, providing flexibility for users wanting to create seamless transitions between spaces. The PIER-40 delivers an impressive heat output and is engineered with advanced technology to enhance efficiency and reduce environmental impact. With optional features like LED lighting and customizable front panels, the PIER-40 can cater to various design preferences and settings, from cozy interiors to stylish outdoor living areas.

Both models incorporate innovative technologies such as electronic ignition systems and adjustable flame settings, allowing users to tailor their experience. They also prioritize safety, featuring glass doors that prevent direct contact with flames and heat. Furthermore, they are built with durable materials designed to withstand the rigors of regular use.

In terms of energy efficiency, both the BAY-40 and PIER-40 meet stringent guidelines, often exceeding standard requirements. This not only reduces utility bills for homeowners but also aligns with a growing emphasis on sustainable living.

Overall, Hearth and Home Technologies' BAY-40 and PIER-40 fireplaces represent a commitment to quality, innovation, and user satisfaction. With their blend of modern design, advanced engineering, and customizable features, they are excellent choices for anyone looking to add warmth and style to their home or outdoor space while keeping efficiency and environmental considerations in mind.