Hearth and Home Technologies Supreme-XTS, Grand-XTS Glass Assembly, Air Shutter Setting

Page 27

F. Glass Assembly

WARNING

Handle glass doors with care.

Inspect the gasket to ensure it is undamaged.

Inspect the glass for cracks, chips or scratches.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass door removed, cracked, broken or scratched.

Replace glass door assembly as a complete appliance.

Removing Glass Assembly

The glass assembly fastens to the fireplace in four places. Two or four of the fastening mechanisms will be spring- loaded glass latches, depending on the model. An ex- ample of the glass latch is shown in Figure 11.5.

Supreme-XTS

To release glass assembly, pull the two bottom spring- loaded latches forward and allow them to retract away from the glass assembly. Remove glass assembly by carefully pulling the bottom side of the glass assembly out first. Carefully slide the glass assembly outward and downward until the top tabs are disengaged from the slots.

Grand-XTS

To release glass assembly, pull the two bottom spring- loaded latches forward and allow them to retract away from the glass assembly. Slide the glass assembly outward and downward until the top latches disengage.

Replacing Glass Assembly

Supreme-XTS

Tilt glass assembly toward fireplace and slide glass assembly up to engage top two tabs with the corresponding slots. Fasten the two bottom latches.

Grand-XTS

Tilt glass assembly toward fireplace and slide glass as- sembly upward to engage top latches. Verify top latches are fully engaged and then fasten the two bottom latches.

GLASS ASSEMBLY

BOTTOM LATCH

Figure 11.5 Glass Assembly

G. Air Shutter Setting

Optimal flame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician.

Model

NG

LP

Grand-XTS

1/2 in.

Full Open (3/4 in.)

Supreme-XTS

3/8 in.

Full Open (3/4 in.)

Heat & Glo • Supreme-XTS, Grand-XTS349-901 Rev. G • 9/08

27

 

Image 27 Contents
What to do if you smell gas Models Supreme-XTS Grand-XTSHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Inspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededMinimum Fireplace Opening Fireplace Size RequirementsClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Placing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap Factory Built Wood BurningDamper Flashing Kit Optional Gas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Appliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationOptional Accessories Junction Box InstallationFAN Junction BOX Mantel Projections FinishingEmber Placement Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Set Assembly LOGS-SXTHeat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Log Set Assembly LOGS-GXT Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Air Shutter Setting Glass AssemblyOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceInitial Break-in Procedure Check Pilot Flame AppearanceAfter Appliance is Lit Issue Solutions Frequently Asked QuestionsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsPart number list on following At Depot SUPREME-XTSGRAND-XTS LOGS-GXT Service PartsStocked Standing Pilot Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information