Hearth and Home Technologies Grand-XTS Check Pilot Flame Appearance, After Appliance is Lit

Page 30

C. Check Pilot Flame Appearance

Pilot flame must contact the thermocouple and thermopile for reliable appliance operation.

Pilot flame should be as shown in Figure 12.1.

Figure 12.1 Proper Pilot Flame

If adjustment is needed remove cap screw from gas valve using 1/8 inch standard screwdriver (see Figure 12.2).

Turn adjustment screw clockwise to increase pilot flame size. Make small adjustments.

PILOT

ADJUSTMENT

Figure 12.2 Adjustments

Do NOT turn adjustment screw counter-clockwise too far as it will come out of the valve allowing gas to escape.

Replace cap screw and seal to prevent gas leaks.

Check for gas leaks after tightening.

D. After Appliance is Lit

WARNING

Glass door must be in place when appliance is operating.

Risk of:

Combustion Fumes

Fire

Do NOT operate appliance with glass door removed.

Open viewing glass for servicing only.

Glass door MUST be in place and sealed before operating appliance.

Only use glass door certified for use with appliance.

Glass replacement should be done by qualified technician.

Initial Break-in Procedure

When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal.

Note: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

30

Heat & Glo • Supreme-XTS, Grand-XTS349-901 Rev. G • 9/08

 

Image 30
Contents Models Supreme-XTS Grand-XTS What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsFireplace Size Requirements Minimum Fireplace OpeningClearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesHorizontal Venting Vent Information and DiagramsVent Table Key Measuring StandardsInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Placing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap Factory Built Wood BurningDamper Flashing Kit Optional Gas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Electrical Information Wiring the ApplianceON/OFF Switch Appliance RequirementsJunction Box Installation Optional AccessoriesFAN Junction BOX Finishing Mantel ProjectionsAccessories Appliance SetupClean the Appliance Ember PlacementLog Set Assembly LOGS-SXT Positioning the LogsHeat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Log Set Assembly LOGS-GXT Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Glass Assembly Air Shutter SettingOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Lighting Appliance Standing Pilot IgnitionInitial Break-in Procedure Check Pilot Flame AppearanceAfter Appliance is Lit Frequently Asked Questions Issue SolutionsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionMaintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsLog Set Assembly Service PartsPart number list on following SUPREME-XTS At DepotGRAND-XTS Service Parts LOGS-GXTStanding Pilot Valve Assembly StockedCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Supreme-XTS, Grand-XTS specifications

Hearth and Home Technologies (HHT) has consistently set the bar in the realm of modern heating solutions, and their Grand-XTS and Supreme-XTS models exemplify this commitment to innovation and quality. These sleek and stylish gas fireplaces are designed not only to provide warmth but also to enhance the aesthetic of any living space.

The Grand-XTS model features a stunning design that can be customized to fit various interior styles. With an expansive viewing area, it allows for an impressive flame presentation that creates a cozy ambiance. The inclusion of MaxHeat technology ensures optimal heat output, making it an efficient choice for heating larger areas without sacrificing style. This model is equipped with a powerful fan system that circulates warm air throughout the room quickly, enhancing the overall comfort of your living space.

Meanwhile, the Supreme-XTS takes luxury to the next level with additional modern features. Designed for elegance, it comes with a range of decorative options, including various media beds and reflective panels that amplify the fire's glow. The fireplace's Intellifire Ignition System offers a convenient and reliable startup, ensuring that users can enjoy their fireplace with minimal hassle. Furthermore, the Supreme-XTS integrates seamlessly with smart home systems, allowing for remote operation and personalized settings directly from your smartphone.

Both models offer customizable options, including adjustable flame heights and temperature settings. This versatility lets homeowners create their desired atmosphere, whether for a warm, welcoming gathering or a more intimate setting. The advanced safety features incorporated into both models, such as automatic shut-off systems and glass safety screens, provide peace of mind while allowing for an unparalleled heating experience.

The Grand-XTS and Supreme-XTS by Hearth and Home Technologies not only prioritize efficiency and safety but also cater to individual tastes with a selection of finishes and trim options. With their superior performance, elegant aesthetics, and advanced technology, these fireplaces stand out as a premier choice for those looking to enhance both comfort and visual appeal in their homes. Whether you choose the Grand-XTS for its expansive heat capabilities or the Supreme-XTS for its luxurious features, either model will transform your living space into a haven of warmth and style.