Hearth and Home Technologies Grand-XTS Check Pilot Flame Appearance, After Appliance is Lit

Page 30

C. Check Pilot Flame Appearance

Pilot flame must contact the thermocouple and thermopile for reliable appliance operation.

Pilot flame should be as shown in Figure 12.1.

Figure 12.1 Proper Pilot Flame

If adjustment is needed remove cap screw from gas valve using 1/8 inch standard screwdriver (see Figure 12.2).

Turn adjustment screw clockwise to increase pilot flame size. Make small adjustments.

PILOT

ADJUSTMENT

Figure 12.2 Adjustments

Do NOT turn adjustment screw counter-clockwise too far as it will come out of the valve allowing gas to escape.

Replace cap screw and seal to prevent gas leaks.

Check for gas leaks after tightening.

D. After Appliance is Lit

WARNING

Glass door must be in place when appliance is operating.

Risk of:

Combustion Fumes

Fire

Do NOT operate appliance with glass door removed.

Open viewing glass for servicing only.

Glass door MUST be in place and sealed before operating appliance.

Only use glass door certified for use with appliance.

Glass replacement should be done by qualified technician.

Initial Break-in Procedure

When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal.

Note: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

30

Heat & Glo • Supreme-XTS, Grand-XTS349-901 Rev. G • 9/08

 

Image 30 Contents
Models Supreme-XTS Grand-XTS What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsFireplace Size Requirements Minimum Fireplace OpeningClearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesHorizontal Venting Vent Information and DiagramsVent Table Key Measuring StandardsInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Placing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap Factory Built Wood BurningDamper Flashing Kit Optional Gas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Electrical Information Wiring the ApplianceON/OFF Switch Appliance RequirementsJunction Box Installation Optional AccessoriesFAN Junction BOX Finishing Mantel ProjectionsAccessories Appliance SetupClean the Appliance Ember PlacementLog Set Assembly LOGS-SXT Positioning the LogsHeat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Log Set Assembly LOGS-GXT Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. G 9/08 Glass Assembly Air Shutter SettingOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Lighting Appliance Standing Pilot IgnitionInitial Break-in Procedure Check Pilot Flame AppearanceAfter Appliance is Lit Frequently Asked Questions Issue SolutionsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionMaintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsLog Set Assembly Service PartsPart number list on following SUPREME-XTS At DepotGRAND-XTS Service Parts LOGS-GXTStanding Pilot Valve Assembly StockedCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information