Hearth and Home Technologies RUTHERFORD-42 Mailbox Style Shroud radiation shield required

Page 37

Mailbox Style Shroud (radiation shield required)

 

 

 

 

 

TR11/11T

TR11/11T TV

 

 

 

 

 

Min. Base Dims.

 

 

 

3 in. (76 mm)

in

34 x 34

28 x 30

 

 

Min. Opening Height

 

 

 

 

 

mm

864 x 864

711 x 762

 

 

 

 

Min. Height

 

 

 

Min. Height Above Radiation Shield

 

 

 

 

 

 

in

21-1/4

20-1/2

above radiation

 

 

 

 

 

 

shield

 

 

 

mm

540

521

 

 

Min. Base Dim

 

Min. Opening Width

 

 

 

Min.

 

 

 

in

28 x 28

22 x 24

 

 

 

 

 

 

 

 

 

 

 

 

mm

711 x 711

559 x 610

Base Dim

 

Min. Opening Width

 

 

 

 

 

3 in. (76 mm) Min.

Radiation Shield Height

from top of Chase

Figure 10.3 Mailbox Style Shroud Dimensions

Roofed Style Shroud (Radiation Shield Required)

Minimum

Height above

Radiation Shield

 

 

TR11/11T

TR11/11T TV

 

 

Min. Base Dims.

 

in

34 x 34

34 x 34

 

 

 

 

 

mm

864 x 864

864 x 864

Minimum

Min. Height Above Radiation Shield

in

16

16

Opening

3 in. (76 mm) Radiation

Shield Height

Termination

Cap

Radiation Shield

Chase Top

Min. Base Dimension

Height

mm

406

406

 

 

Min. Opening Width

Minimum

in

28

28

Base Dimension

mm

711

711

 

 

Min. Opening Height

Min. Opening Width

in

12

12

 

 

 

mm

305

305

 

Figure 10.4 Roofed Style Shroud Dimensions

Heat & Glo • RUTHERFORD-424059-309 Rev G • 11/08

37

Image 37 Contents
Fire Risk Hot screen/mesh and glass doors will cause burnsGrate Listing Label Information/LocationNumber Table of Contents CONDITIONS, Exclusions & Limitation of Liability ÎWarranty Hearth & Home Technologies Limited WarrantyHeat & Glo RUTHERFORD-42 4059-309 Rev G 11/08 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsStarting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceHardwood vs Softwood Wood FuelChimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Check Firebox Molded Brick Panel Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDraft Design and Installation ConsiderationsNegative Pressure Recommended Chimney Locations Locating your Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededTypical Fireplace Components Select Fireplace Location Framing & ClearancesAir Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsThings to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsYES Outside Air Installation Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssembling Chimney Sections Assemble Chimney SectionsInstalling the Ceiling Firestop Install Ceiling FirestopsPrepare Attic Insulation Shield Install Attic Insulation ShieldInstall Flashing Complete InstallationCut Out Hole in Roof Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase Installations Install Chase Top Install Fireplace & ChimneyST1175 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Radiation Shield ShroudsField Constructed Shrouds Mailbox Style Shroud radiation shield required Install Hearth Molded Brick Panel Installation of Molded Brick PanelInstall Side Molded Brick Panel-Traditional Install Back Molded Brick Panel-TraditionalInstalling Back Molded Brick Panel-Her- ringbone Installing Side Molded Brick Panel-Herring- boneInstall Screens Install MortarHearth Extension Finishing= 1/k x inches of thickness Framing Material NoncombustibleEquivalent insulation Finishing MaterialsNon-combustible Sealant Noncombustible Facing Finishing MaterialCombustible Mantel 14 Secure to Framing Mantel, Adding Extra SupportBrick Front Gas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace DimensionsID6 Insulated Duct .4 mm i.d 1067 mm UD6 Uninsulated Duct Catalog # Chimney Components15-1/4 387 mm 31-3/4 806 mm 34-5/8 879 mm CT56 Chase Top Parts ServiceDo not Discard this Manual