C. Intellifire Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance junction box for operation. A wiring diagram is shown in Fig- ure 10.2.
This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the sup- plied junction box. It is highly recommended that the junction box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not included). Batteries cannot be placed in the battery pack while using the 3 volt AC transformer. Conversely, the transformer must be unplugged if the battery pack is used.
CAUTION
Battery polarity must be correct or module damage will occur.
Optional Accessories Requirements
Wiring for optional accessories should be done now to avoid reconstruction.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
CAUTION
Shock Risk
•Replace damaged wire with type 105° C rated wire.
•Wire must have high temperature insulation.
Wall Switch
GRN*
BLU
WHT
* GRN wire only used with optional wall switch
Battery
Pack
| - | + | To | |
| + | - | Junction | |
Limit | Box | |||
|
| |||
Switch |
|
| 3V | |
|
|
| ||
|
| Adaptor | ||
|
|
| BLK | |
| BLK |
| RED | |
|
|
| ||
|
|
| BRN | |
| RED |
|
| |
|
|
| Valve |
Ignitor
Control Box ORG
BLK
ORG
GRN
Flame
Sensor
Pilot Assembly
WHT
Ground Romex
BLACK
WHITE
Figure 10.2 Intellifire Pilot Ignition (IPI) Wiring Diagram
GROUND