Hearth and Home Technologies RBV4842IT, RBV4842IH, RBV4236IH, RBV4236IT owner manual Dckn-Rbv

Page 43

 

 

Service Parts

RBV4236 & RBV4842

 

 

 

 

 

 

 

 

 

 

 

 

Service Parts List

 

 

 

Beginning Manufacturing Date: N/A

 

 

 

 

 

Ending Manufacturing Date: Active

 

 

36 in. and 42 in. REVEAL Gas Fireplace - BV

 

 

 

 

 

 

 

 

(parts listed in bold italics are critical parts)

 

 

 

 

#

Description of Part

RBV4236IT

RBV4236IH

RBV4842IT

RBV4842IH

Qty.req.

 

 

Valve Assembly

4048-014

4048-014

4048-014

4048-014

1

 

1

10 in. Stainless Steel Flex Gas Line

15696B

 

15696B

15696B

15696B

1

 

2

ON/OFF Valve

15697

 

15697

15697

15697

1

 

3

Brass Connector - Male - Flex

17069

 

17069

17069

17069

2

 

 

Velcro Hook SJ3541

17439A

 

17439A

17439A

17439A

2

 

 

Velcro Loop SJ3542

17440A

 

17440A

17440A

17440A

2

 

 

Long Cable Tie

19954A

 

19954A

19954A

19954A

1

 

4

Pilot Assembly

2090-012

2090-012

2090-012

2090-012

1

 

5

Flexible Bulkhead

4021-086

4021-086

4021-086

4021-086

1

 

6

Valve Bracket

4048-132

4048-132

4048-132

4048-132

1

 

7

Valve

593-500

 

593-500

593-500

593-500

1

 

8

Wire Assembly

593-590A

593-590A

593-590A

593-590A

1

 

9

Control Module

593-592

 

593-592

593-592

593-592

1

 

10

3V Adapter

593-593A

593-593A

593-593A

593-593A

1

 

 

HIBLK60FM Wire Assembly

34937

 

34937

34937

34937

1

 

 

18 AWG 200C Black Wire

9010

 

9010

9010

9010

5 ft.

 

 

Wall Switch Wire Assembly

4018-018

4018-018

4018-018

4018-018

1

 

 

HIBLU60FF Wire Assembly

4018-019

4018-019

4018-019

4018-019

1

 

 

Orifice - Style C

582-831

 

582-831

4021-391

4021-391

1

 

 

Limit Switch

4021-383

4021-383

4021-383

4021-383

1

 

 

Battery Pack

593-594A

593-594A

593-594A

593-594A

1

 

 

Natural Gas Conversion Kit

DCKN-RBV

DCKN-RBV

DCKN-RBV

DCKN-RBV

1

 

 

Propane Gas Conversion Kit

DCKP-RBV

DCKP-RBV

DCKP-RBV

DCKP-RBV

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07

43

Image 43
Contents What to do if you smell gas RBV4236IH RBV4236IT RBV4842IH RBV4842ITListing Label Information/Location CongratulationsTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsAsphyxiation Risk Negative PressureInspect the Appliance and Components Tools and Supplies NeededAny such action may cause a fire hazard Model # Framing and ClearancesSelect Appliance Location Fire RiskConstruct the Appliance Chase Fire Risk Odor Risk ClearancesRough Opening Model # Width Height Depth Max Mantel Leg or Perpendicular Wall Mantel ProjectionsTermination Caps Staggered Height Termination LocationsVent Termination Minimum Clearances Fire Risk Explosion RiskVent Guidelines Vent Information and DiagramsVent System Configuration Elbow Distance is 50% of vertical Vent height Vertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingAppliance Preparation Installing Outside Air KitFire Risk Gas and Electrical ConnectionsSecuring and Leveling Appliance Risk of Smoke SpillageSecuring Vent Sections Installing Vent PipeAttach Vent to Firebox Assembly Assemble Vent SectionsGas Leak Risk Gas InformationFuel Conversion Gas Connection Gas PressureCheck for GAS Leaks Shock Risk Explosion Risk Recommendation for WireConnecting to the Appliance Electrical InformationShock Risk Intellifire Ignition System WiringJunction Box Installation Facing Material FinishingLog Assembly Appliance SetupClean the Appliance AccessoriesPlacing the Lava Rock and Vermiculite Lava Rock, Vermiculite, Rockwool PlacementReveal Log Set Log Removal/ReplacementHood Glass DoorsFire Risk Combustion Fumes Risk 16 Remove Screws Attaching Front Burner Support Air Shutter SettingBefore Operating This Appliance Operating InstructionsFire Risk Burn Risk Check Appliance Draft High Limit Safety SwitchLighting the Appliance For Your Safety Read Before LightingAfter the Appliance is Lit Frequently Asked QuestionsFire Risk High Temperatures Issue SolutionsSymptom Possible Causes Corrective Actions TroubleshootingIntellifire Ignition System Symptom Possible Causes Corrective Actions Maintaining and Servicing the Appliance Inspect Maintenance Tasks Maintenance and Service TasksReference Materials Appliance Dimension DiagramModel This page intentionally left blank Service Parts List Service Parts RBV4236 & RBV4842Description of Part RBV4236 & RBV4842Service Parts RBV4236 & RBV4842 DCKN-RBV 1112 RBV4236 & RBV4842 UD4 Uninsulated Duct Optional ComponentsHow to Obtain Service Limited Lifetime WarrantyLimited Lifetime Warranty Year Limited WarrantyDo Discardnot