Hearth and Home Technologies ST-36TRB-IPI, RCOR-36TRB-IPI Table of Contents, User Guide

Page 3

Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Tempered Glass Specifications . . . . . . . . . . . . . . . . . . . . . 7 C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 7 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 7 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 C. Fan Kit (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 E. Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . . 10 F. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 G. Remote Controls, Wall Controls and Wall Switches. . . . . 10 H. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 10 I. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 11 J. After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 K. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 12

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 13 B. Maintenance Tasks-Qualified Service Technician . . . . . . 14

Installer Guide

4 Getting Started

A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 16

B. Design and Installation Considerations . . . . . . . . . . . . . . 17

C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 17

D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 17

5 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . 18

B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . 19

C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

D. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 21

6 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 23

B. Continue Adding Vent Components . . . . . . . . . . . . . . . . . 25

C. Install Support Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . 25

7 Vent Information and Diagrams

A. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

B. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

C. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

D. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 37 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 37 C. Vertical Penetration Framing . . . . . . . . . . . . . . . . . . . . . . 38 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 39

9 Appliance Preparation

A. Top Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

B. Rear Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

C. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 42

10 Installing Vent Pipe (DVP and SLP Pipe)

A. Assemble Vent Sections (DVP Pipe Only) . . . . . . . . . . . . 43 B. Assemble Vent Sections (SLP Pipe Only) . . . . . . . . . . . . 44 C. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 44 D. Secure the Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . 45 E. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 45 F. Install Decorative Ceiling Components (SLP only). . . . . . 46 G. Install Metal Roof Flashing . . . . . . . . . . . . . . . . . . . . . . . . 47 H. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 47 I. Install RF4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 J. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 49 K. Install Decorative Wall Components (SLP only). . . . . . . . 49 L. Heat Shield Requirements for Horizontal Termination . . . 49 M. Install Horizontal Termination Cap (DVP and SLP Pipe) . 50

11 Gas Information

A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 51

Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI2128-900 Rev B. • 10/08

3

Image 3
Contents Models What to do if you smell gasHot glass will cause burns Homeowner Reference Information CongratulationsUser Guide Table of ContentsFinishing Appliance SetupTroubleshooting Electrical InformationCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalFinal inspection by Turn off all electric power to the applianceOn position. The ON/OFF switch may Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsRemote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseRCOR-36TRB-IPI PIER/LCOR/RCOR Non-Combustible Mantel Mantel and Wall Projections See-Through Combustible MantelPIER/LCOR/RCOR Combustible Mantel See-Through Non-Combustible MantelTOP View Fireplace Opening Vent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Install Support Brackets To Install the Heat ShieldContinue Adding Vent Components Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyTo SLP series vent pipe, if desired Vent DiagramsV1 Minimum H1 + H2 Maximum Top Vent Horizontal Termination One ElbowTwo Elbows V1 Minimum H1 MaximumTop Vent Horizontal Termination Three Elbows Exhaust restrictor Instructions E a K R E Two Elbows Three Elbows Maximum + V 2 MinimumH1+ H2 V1 + V2 Minimum H1+ H2 Maximum Page Rear Vent Horizontal Termination Two Elbows H1 Maximum V1 Minimum H2 Maximum H1+ H2 MaximumH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Rear Vent Vertical Termination One Elbow V1 Minimum H1 MaximumV1 Minimum H1 + H2 Maximum Rear Vent Vertical Termination Three Elbows H1 Maximum V1 Minimum H1+ H2 MaximumV1 Minimum H1+ H2+ H3 Maximum Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP SLP Vertical Penetration FramingInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentProceed to . C Cut the metal retaining band Rear VentAttach Nailing Tab to Front Corner of Unit Securing and Leveling the ApplianceAssemble Pipe Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingSLP-FS Install RF4-8Install Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Gas Connection Gas InformationFuel Conversion Gas PressureElectrical Service and Repair Wiring RequirementsIntellifire Ignition System Wiring Optional Accessories RequirementsIntellifire Ignition Wiring Diagram with Remote Receiver Wall Switch Installation for Fan Optional Junction Box InstallationTo install the Splatter Guard FinishingSplatter Guard To Remove the Splatter Guard To Close the Lower Access PanelPIER/LCOR/RCOR Mantel Projection Mantel and Wall Projections See-Through Mantel ProjectionFacing Material Finishing MaterialFinishing materials over 1 inch thick Elevated Hearth Systems Appliance Setup 2128-935 Install the Log AssemblyIndentations Install Trim Kits and Surrounds Air Shutter SettingAir Shutter Settings Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Remove any contaminants that may have accumulated on Appliance Dimension Diagram Reference MaterialsLocation Inches Millimeters Electrical Access GAS Line Left View Front View Right View Electrical DVP vent components Vent Components DiagramsHorizontal Termination Cap DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC213-3/4 13-7/8 352 mm 349 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mmRoof Flashing Multi-pak 13-3/4 11-7/8 349 mm 302 mmDVP-TV DVP-HRC-SS RF4-8 Elbow660 mm Extended Heat ShieldBlack Support Box-Black Wall Thimble-BlackAdapter Service Parts Log Set AssemblyAt Depot Service Parts ListPIER-36TRB-IPI Stocked LCOR-36TRB-IPI SRV2132-FACE RCOR-36TRB-IPI RCOR-36TRB-IPI ST-36TRB-IPI, PIER-36TRB-IPI Contact Information

PIER-36TRB-IPI, LCOR-36TRB-IPI, ST-36TRB-IPI, RCOR-36TRB-IPI specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, offering a range of innovative and efficient heating solutions. Among their standout products are the RCOR-36TRB-IPI, ST-36TRB-IPI, LCOR-36TRB-IPI, and PIER-36TRB-IPI, which present an attractive blend of aesthetics and functionality.

The RCOR-36TRB-IPI is designed with a contemporary linear shape that can be the centerpiece of any living space. One of its main features is the advanced IntelliFire® ignition system, allowing for easy lighting and enhanced reliability. This model boasts an extensive selection of flame adjustment options, providing users with the ability to customize the fire's appearance to fit their mood. Additionally, it offers an impressive direct vent technology, ensuring optimal efficiency and maintaining indoor air quality by drawing air from outside.

The ST-36TRB-IPI takes traditional elements and fuses them with modern efficiency. This model is compatible with various styles of venting, making it versatile for different home layouts. Its clear, tempered glass front adds a touch of elegance while maximizing heat output. With a built-in blower option, the ST-36TRB-IPI circulates warmth effectively throughout larger spaces. The easy-to-use remote control enhances user experience, allowing homeowners to manage their heating with convenience.

The LCOR-36TRB-IPI is another exciting option, featuring a more rustic design perfect for those looking to bring a touch of traditional charm into their home. This model is equipped with a powerful heat exchanger that optimizes heat output while minimizing fuel consumption. The LCOR-36TRB-IPI also promotes safety with its glass safety barrier, ensuring that the flames are safely contained.

Finally, the PIER-36TRB-IPI is all about dramatic beauty and functionality. This model features a unique, vertical design that sets it apart in any room. It utilizes advanced combustion technology, creating a clean-burning, efficient fire. Equipped with innovative heat management features, the PIER-36TRB-IPI delivers warmth where it's needed most, while also enhancing the ambiance of the space.

In summary, the RCOR-36TRB-IPI, ST-36TRB-IPI, LCOR-36TRB-IPI, and PIER-36TRB-IPI from Hearth and Home Technologies cater to various tastes and needs, combining leading-edge technology with impressive heating capabilities. These models not only provide warmth but also elevate the aesthetic appeal of any home, making them an excellent investment for comfort and style.