Hearth and Home Technologies LCOR-36TRB-IPI, RCOR-36TRB-IPI, PIER-36TRB-IPI owner manual Electrical

Page 69

Ø K

N

 

L

M

ELECTRICAL

ACCESS

 

Ø K

O

P

E

A

B

LEFT VIEW

FRONT VIEW

C D

GAS LINE

ACCESS

F

G

RIGHT VIEW

J

i

H

Location

Inches

Millimeters

A

36

914

B

40-1/2

1029

C

24-1/2

622

D

33-1/2

851

E

1

25

F

2-1/8

54

G

4-1/8

105

H

4-1/4

108

Location

Inches

Millimeters

I

1-1/2

38

J

27

686

K

8

203

L

12

305

M

9-1/2

241

N

24-1/2

622

O

38

965

P

34-5/8

880

Figure 16.3 LCOR, RCOR Dimensions

Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI2128-900 Rev B. • 10/08

69

Image 69
Contents Models What to do if you smell gasHot glass will cause burns Homeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupElectrical Information FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceOn position. The ON/OFF switch may Turn off all electric power to the applianceLighting Instructions IPI Final inspection byAfter Fireplace is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianVenting LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Any such action may cause a fire hazardSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseRCOR-36TRB-IPI PIER/LCOR/RCOR Combustible Mantel Mantel and Wall Projections See-Through Combustible MantelSee-Through Non-Combustible Mantel PIER/LCOR/RCOR Non-Combustible MantelTOP View Fireplace Opening Vent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Install Support Brackets To Install the Heat ShieldContinue Adding Vent Components Approved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsTo SLP series vent pipe, if desired Vent DiagramsTwo Elbows Top Vent Horizontal Termination One ElbowV1 Minimum H1 Maximum V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows Exhaust restrictor Instructions E a K R E Two Elbows Three Elbows Maximum + V 2 MinimumH1+ H2 V1 + V2 Minimum H1+ H2 Maximum Page Rear Vent Horizontal Termination Two Elbows H1 Maximum V1 Minimum H2 Maximum H1+ H2 MaximumH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Rear Vent Vertical Termination One Elbow V1 Minimum H1 MaximumV1 Minimum H1 + H2 Maximum Rear Vent Vertical Termination Three Elbows H1 Maximum V1 Minimum H1+ H2 MaximumV1 Minimum H1+ H2+ H3 Maximum Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe DVP SLP Vertical Penetration FramingInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentProceed to . C Cut the metal retaining band Rear VentAttach Nailing Tab to Front Corner of Unit Securing and Leveling the ApplianceAttach Vent to the Firebox Assembly Installing Vent Pipe DVP and SLP PipeAssemble Vent Sections DVP Pipe Only Assemble Pipe Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingSLP-FS Install RF4-8Install Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Fuel Conversion Gas InformationGas Pressure Gas ConnectionIntellifire Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical Service and RepairIntellifire Ignition Wiring Diagram with Remote Receiver Wall Switch Installation for Fan Optional Junction Box InstallationTo install the Splatter Guard FinishingSplatter Guard To Remove the Splatter Guard To Close the Lower Access PanelPIER/LCOR/RCOR Mantel Projection Mantel and Wall Projections See-Through Mantel ProjectionFacing Material Finishing MaterialFinishing materials over 1 inch thick Elevated Hearth Systems Appliance Setup 2128-935 Install the Log AssemblyIndentations Install Trim Kits and Surrounds Air Shutter SettingAir Shutter Settings Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Remove any contaminants that may have accumulated on Appliance Dimension Diagram Reference MaterialsLocation Inches Millimeters Electrical Access GAS Line Left View Front View Right View Electrical DVP vent components Vent Components DiagramsHorizontal Termination Cap DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mm302 mm 13-3/4 13-7/8 352 mm 349 mmDVP-TV DVP-HRC-SS 660 mm ElbowExtended Heat Shield RF4-8Black Support Box-Black Wall Thimble-BlackAdapter Service Parts Log Set AssemblyAt Depot Service Parts ListPIER-36TRB-IPI Stocked LCOR-36TRB-IPI SRV2132-FACE RCOR-36TRB-IPI RCOR-36TRB-IPI ST-36TRB-IPI, PIER-36TRB-IPI Contact Information

PIER-36TRB-IPI, LCOR-36TRB-IPI, ST-36TRB-IPI, RCOR-36TRB-IPI specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, offering a range of innovative and efficient heating solutions. Among their standout products are the RCOR-36TRB-IPI, ST-36TRB-IPI, LCOR-36TRB-IPI, and PIER-36TRB-IPI, which present an attractive blend of aesthetics and functionality.

The RCOR-36TRB-IPI is designed with a contemporary linear shape that can be the centerpiece of any living space. One of its main features is the advanced IntelliFire® ignition system, allowing for easy lighting and enhanced reliability. This model boasts an extensive selection of flame adjustment options, providing users with the ability to customize the fire's appearance to fit their mood. Additionally, it offers an impressive direct vent technology, ensuring optimal efficiency and maintaining indoor air quality by drawing air from outside.

The ST-36TRB-IPI takes traditional elements and fuses them with modern efficiency. This model is compatible with various styles of venting, making it versatile for different home layouts. Its clear, tempered glass front adds a touch of elegance while maximizing heat output. With a built-in blower option, the ST-36TRB-IPI circulates warmth effectively throughout larger spaces. The easy-to-use remote control enhances user experience, allowing homeowners to manage their heating with convenience.

The LCOR-36TRB-IPI is another exciting option, featuring a more rustic design perfect for those looking to bring a touch of traditional charm into their home. This model is equipped with a powerful heat exchanger that optimizes heat output while minimizing fuel consumption. The LCOR-36TRB-IPI also promotes safety with its glass safety barrier, ensuring that the flames are safely contained.

Finally, the PIER-36TRB-IPI is all about dramatic beauty and functionality. This model features a unique, vertical design that sets it apart in any room. It utilizes advanced combustion technology, creating a clean-burning, efficient fire. Equipped with innovative heat management features, the PIER-36TRB-IPI delivers warmth where it's needed most, while also enhancing the ambiance of the space.

In summary, the RCOR-36TRB-IPI, ST-36TRB-IPI, LCOR-36TRB-IPI, and PIER-36TRB-IPI from Hearth and Home Technologies cater to various tastes and needs, combining leading-edge technology with impressive heating capabilities. These models not only provide warmth but also elevate the aesthetic appeal of any home, making them an excellent investment for comfort and style.