Hearth and Home Technologies RH-36 Series Effective Outside Height Diameter 10-1/2 121 mm 267 mm

Page 48

 

Inside

 

Diameter

 

8 in. (203 mm)

Effective

Outside

Height

Diameter

4-3/4 in.

10-1/2 in.

(121 mm)

(267 mm)

SL315/SL330 Offset/Return

Assembled

Diameter: 14 1/2 in./368 mm

Height: 24 in./610 mm

AS8 Straight Attic Insulation Shield

10-1/2 in.

(267 mm)

2 in. (51 mm)

JB877 Chimney Joint Band

10-1/2 in. (267 mm)

CB876 Chimney Joint Band

7 3/4 in.

26 in.

CT-3A

A

B

 

14-1/2 in.

 

 

(368 mm)

 

Ceiling Firestop

 

 

 

 

 

 

 

Catalog #

A

 

B

FS338

0-deg.

14-1/2 in.

 

368 mm

FS339

15-deg.

18-3/8 in.

 

467 mm

 

 

 

 

 

FS340

30-deg.

23 in.

 

584 mm

12in.

(305 mm)

27-3/8 in.

24-5/8 in.

(695 mm)

(625 mm)

RF370 Roof Flashing

12in.

(305 mm)

31 in.

24-5/8 in.

(625 mm)

(787 mm)

 

RF371 Roof Flashing

 

TR-TVK

TR Top Vent Kit

48

Heat & Glo • RH-36/RH-424044-153 • Rev W • 11/08

Image 48 Contents
Wood Burning Fireplace OperationHot screen/mesh and glass doors will cause burns Fire RiskListing Label Information/Location GrateNumber Table of Contents Installer GuideUser Guide Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHeat & Glo RH-36/RH-42 4044-153 Rev W 11/08 Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Seasoned Wood Starting a FireGrate FirescreenGlass Doors Vented Gas Log Sets & Gas Log LightersOptional Components Clear SpaceWood Fuel Maintainance and Service Chimney Inspection/CleaningDisposal of Ashes Creosote Formation and Need for RemovalGlass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionInstaller Guide Getting StartedDesign and Installation Considerations DraftNegative Pressure Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsTools and Supplies Needed Fireplace System RequirementsInspect Fireplace and Components Mm all configurations Framing & ClearancesSelect Fireplace Location Clearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceOutside Di Model # Opening MensionsInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet YESInstall Outside Air Kit Outside Air InstallationChimney Assembly Maintain minimum height of chimney above roofChimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield Prepare Attic Insulation ShieldComplete Installation Install FlashingFollowing steps should be skipped if using a chase Cut out Hole in RoofChimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall as per Sections 7 Caulk all seams to prevent leaks Refer to FigureInstall Termination Cap ST375 Square Termination CapTS345/TS345P Square Termination Cap TCT375 Terra Cotta CapShrouds Radiation ShieldField Constructed Shrouds Open Top Shroud TR342 caps require radiation shieldMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield requiredFinishing Hearth Extension= 1/k x inches of thickness Refer to .2 for hearth extension insulation alternativesRaised Hearth Extension Framing Minimum betweenNon-combustible Sealant Noncombustible Finishing MaterialsFinishing Material In. Micore or equivilent insulationCombustible Mantel Clearances to Mantels or other Combustibles above FireplaceOutside Di- mensions Model Accessories Gas Log/Lighter Provision Wood Burning Inserts Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsModel # 1321 mm 406 mm 1676 mm 508 mm 13 mmID4 Insulated Duct Mm i.d 1067 mm UD4 Uninsulated Duct Air Kit PartsChimney Components Catalog #Effective Outside Height Diameter 10-1/2 121 mm 267 mm 10-1/2 267 mm305 mm 27-3/8 24-5/8 695 mm 625 mm 305 mm 24-5/8 625 mm 787 mm10-7/8 276 mm Service PartsHeat & Glo RH-36/RH-42 4044-153 Rev 11/08Do not Discard this Manual