Hearth and Home Technologies 8000TR-OAK After Fireplace is Lit, Frequently Asked Questions

Page 13

K. After Fireplace is Lit

Initial Break-in Procedure

The fireplace should be run three to four hours continuously on high.

Turn the fireplace off and allow it to completely cool.

Remove fixed glass assembly. See Section 14.H.

Clean fixed glass assembly. See Section 3.

Replace the fixed glass assembly and run continuously on high an additional 12 hours.

This cures the materials used to manufacture the fire- place.

NOTICE! Open windows for air circulation during fire- place break-in.

Some people may be sensitive to smoke and odors.

Smoke detectors may activate.

L.Frequently Asked Questions

ISSUE

SOLUTIONS

 

 

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance warms, this

condensation will disappear.

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the appliance is al-

lowed to burn for 20 to 40 minutes.

 

 

When first operated, this appliance may release an odor for the first several hours. This is caused

Odor from appliance

by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor may

 

also be released from finishing materials and adhesives used around the appliance.

 

This is a normal result of the curing process of the paint and logs. Glass should be cleaned

Film on the glass

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing

 

process. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. See

 

your dealer.

 

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to

Metallic noise

the sound produced by a furnace or heating duct. This noise does not affect the operation or

 

longevity of the appliance.

Is it normal to see the pilot flame burn

In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off when

continually?

ON/OFF is turned off. In a standing pilot system the pilot will always stay on.

Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI2057-900 Rev. P • 11/08

13

Image 13
Contents What to do if you smell gas Models 8000TR-OAK 8000TR-OAK-IPI 8000TRLP-OAKIPIHomeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceFinal inspection by Lighting Instructions IPILighting Instructions Standing Pilot For Your Safety Read Before Lighting Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianVenting LogsEither cobrahead or SIT Typical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseTOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Approved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsTwo Elbows Vent Diagrams Top Vent Horizontal Termination One ElbowV1 Minimum H1 Maximum V1 Minimum H1 + H2 MaximumMinimum Maximum + V 2 Minimum + H 2 Maximum Top Vent Horizontal Termination Three ElbowsBreak Here H1 Maximum V1 + V2 Minimum Top Vent Vertical Termination Two ElbowsPage H1 Maximum V1 Minimum H1+ H2 Maximum Rear Vent Horizontal Termination Two ElbowsH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum H1+ H2 Maximum V1 Minimum Rear Vent Vertical Termination One ElbowRear Vent Vertical Termination Three Elbows Pipe Clearances to Combustibles Vent Clearances and FramingHeat Shield Above First 900 Elbow Combustible Wall Penetration Wall Penetration FramingNon-Combustible Wall Penetration Pipe DVP Install the Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Top Vent Appliance PreparationProceed to Section Rear Vent 11 Proper positioning, leveling and securing of an appliance Securing and Leveling the ApplianceChecking Pilot Plate Completing Grate Set-upAttach Vent to the Firebox Assembly Installing Vent PipeAssemble Vent Sections Assemble Pipe SectionsSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections 10 Rotate Seams for DisassemblyAssemble and Install Storm Collar Install Metal Roof FlashingApply Sealant TOP & Partial Sides Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapAnsi Z223.1 and CAN/CGA-B149 installation codes Install Horizontal Termination CapFuel Conversion Gas InformationGas Pressure Gas ConnectionIntellifire Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Optional Accessories RequirementsIntellifire Pilot Ignition IPI Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingCombustible Mantel Legs or Wall Projections Appliance Setup LOG Tabs Install the Log AssemblyPage Install Trim and/or Surround Install the MeshAir Shutter Setting Air Shutter SettingsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramDVP vent components Vent Components DiagramsDVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 RF6M RF12M DVP-TV Service Parts Log Set AssemblyStocked Service Parts List 8000TR-OAK, 8000TR-OAK-IPIAt Depot 8000TR-OAK-IPI 8000TR-OAK Contact Information

8000TRLP-OAKIPI, 8000TR-OAK-IPI, 8000TR-OAK specifications

Hearth and Home Technologies is renowned for its innovative approach to home heating solutions, and their series of fireplaces is a testament to that commitment. Among their popular offerings are the 8000TR-OAK, 8000TR-OAK-IPI, and 8000TRLP-OAKIPI models. Each of these fireplaces is designed to deliver warmth, ambiance, and advanced technology wrapped in a refined aesthetic.

The 8000TR-OAK model features an impressive viewing area, which allows the flickering flames to be the centerpiece of any room. With a heating capacity that efficiently warms up spaces, it is ideal for both contemporary and traditional settings. One of its main highlights is the realistic log set that adds to the authenticity of the fire experience. The stove's design is not only visually appealing but also engineered for high efficiency, reducing carbon footprints while maximizing heat output.

Moving to the 8000TR-OAK-IPI, this model integrates the innovative IntelliFire Ignition system, ensuring that operation is reliable and energy-efficient. The IPI system allows the fireplace to be controlled with ease, offering both manual and remote-operation options. This model maintains the authentic charm of the traditional fireplace while incorporating modern technology. The 8000TR-OAK-IPI also boasts multiple flame settings, giving users the flexibility to adjust their experience based on mood or season, along with an outstanding ability to maintain heat with minimal energy consumption.

The 8000TRLP-OAKIPI takes versatility a step further by operating on liquid propane, making it ideal for homes that are not connected to natural gas lines. Along with the IntelliFire Ignition technology, this model ensures exceptional efficiency, making it a premium choice for those who prioritize sustainable energy solutions. The design retains the luxurious oak finish found in its counterparts, ensuring it complements any interior decor seamlessly.

All three models share a range of characteristics that set them apart: a robust construction that promises longevity, an array of customizable options, and built-in safety features that instill confidence in operation. They also offer a variety of venting options, giving homeowners flexibility in installation. With Hearth and Home Technologies’ commitment to quality and innovation, the 8000 series fireplaces provide not just heat, but a captivating focal point for home gatherings.