Hearth and Home Technologies 8000TR-OAK-IPI, 8000TRLP-OAKIPI Install Metal Roof Flashing

Page 44

E. Install Metal Roof Flashing

Note: Skip this section if using the RF4-8.

See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof.

Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 10.15.

 

 

HORIZONTAL

 

 

OVERHANG

2 FT.

20 INCHES MIN.

VERTICAL

MIN.

 

 

WALL

 

LOWEST

 

 

 

DISCHARGE

 

 

OPENING

 

GAS DIRECT VENT

 

 

TERMINATION CAP

 

 

 

 

X

 

 

12

 

 

ROOF PITCH

 

 

IS X/ 12

 

H (MIN.) - MINIMUM HEIGHT FROM ROOF

 

TO LOWEST DISCHARGE OPENING

Roof Pitch

 

H (Min.) Ft.

Flat to 6/12........................................1.0*

Over 6/12 to 7/12............................1.25*

Over 7/12 to 8/12..............................1.5*

Over 8/12 to 9/12..............................2.0*

Over 9/12 to 10/12............................. 2.5

Over 10/12 to 11/12 ......................... 3.25

Over 11/12 to 12/12 ........................... 4.0

Over 12/12 to 14/12........................... 5.0

Over 14/12 to 16/12........................... 6.0

Over 16/12 to 18/12........................... 7.0

Over 18/12 to 20/12........................... 7.5

Over 20/12 to 21/12........................... 8.0

* 3 foot minimum in snow regions

Figure 10.14 Minimum Height From Roof To Lowest Discharge

Opening

 

 

NOTICE: Failure to properly caulk the roof flashing could cause water entry.

Caulk the gap between the roof flashing and the outside diameter of the pipe.

Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 10.15.

CAULK

Figure 10.15

F. Assemble and Install Storm Collar

CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

Connect both halves of the storm collar with two screws (see Figure 10.16).

Wrap the storm collar around the exposed pipe section closest to the roof and align brackets. Insert a bolt (provided) through the brackets and tighten the nut to complete the storm collar assembly. Make sure the collar is tight against the pipe section.

Slide the assembled storm collar down the pipe section until it rests on the roof flashing (see Figure 10.17).

Caulk around the top of the storm collar (see Figure 10.23).

Figure 10.16 Assembling the Storm Collar

Figure 10.17 Assembling the Storm Collar Around the Pipe

44

Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI2057-900 Rev. P • 11/08

Image 44
Contents Models 8000TR-OAK 8000TR-OAK-IPI 8000TRLP-OAKIPI What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceLighting Instructions IPI Final inspection byFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFrequently Asked Questions After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections TOP ViewTermination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal Termination One Elbow Two ElbowsV1 Minimum H1 Maximum V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows Minimum Maximum + V 2 Minimum + H 2 MaximumBreak Here Top Vent Vertical Termination Two Elbows H1 Maximum V1 + V2 MinimumPage H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum Rear Vent Horizontal Termination Two ElbowsH1 Maximum V1 Minimum H1+ H2 Maximum Rear Vent Vertical Termination One Elbow H1+ H2 Maximum V1 MinimumRear Vent Vertical Termination Three Elbows Heat Shield Above First 900 Elbow Vent Clearances and FramingPipe Clearances to Combustibles Non-Combustible Wall Penetration Wall Penetration FramingCombustible Wall Penetration Install the Ceiling Firestop Pipe DVPVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Proceed to Section Appliance PreparationTop Vent Rear Vent Securing and Leveling the Appliance 11 Proper positioning, leveling and securing of an applianceCompleting Grate Set-up Checking Pilot PlateInstalling Vent Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Secure the Vent Sections10 Rotate Seams for Disassembly Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 Apply Sealant TOP & Partial SidesInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap Ansi Z223.1 and CAN/CGA-B149 installation codesGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Intellifire Ignition System WiringStanding Pilot Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair Intellifire Pilot Ignition IPI Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalCombustible Mantel Legs or Wall Projections FinishingFacing Material Appliance Setup Install the Log Assembly LOG TabsPage Install the Mesh Install Trim and/or SurroundAir Shutter Setting Air Shutter SettingsStanding Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP vent componentsDVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 RF6M RF12M DVP-TV Log Set Assembly Service PartsAt Depot Service Parts List 8000TR-OAK, 8000TR-OAK-IPIStocked 8000TR-OAK-IPI 8000TR-OAK Contact Information

8000TRLP-OAKIPI, 8000TR-OAK-IPI, 8000TR-OAK specifications

Hearth and Home Technologies is renowned for its innovative approach to home heating solutions, and their series of fireplaces is a testament to that commitment. Among their popular offerings are the 8000TR-OAK, 8000TR-OAK-IPI, and 8000TRLP-OAKIPI models. Each of these fireplaces is designed to deliver warmth, ambiance, and advanced technology wrapped in a refined aesthetic.

The 8000TR-OAK model features an impressive viewing area, which allows the flickering flames to be the centerpiece of any room. With a heating capacity that efficiently warms up spaces, it is ideal for both contemporary and traditional settings. One of its main highlights is the realistic log set that adds to the authenticity of the fire experience. The stove's design is not only visually appealing but also engineered for high efficiency, reducing carbon footprints while maximizing heat output.

Moving to the 8000TR-OAK-IPI, this model integrates the innovative IntelliFire Ignition system, ensuring that operation is reliable and energy-efficient. The IPI system allows the fireplace to be controlled with ease, offering both manual and remote-operation options. This model maintains the authentic charm of the traditional fireplace while incorporating modern technology. The 8000TR-OAK-IPI also boasts multiple flame settings, giving users the flexibility to adjust their experience based on mood or season, along with an outstanding ability to maintain heat with minimal energy consumption.

The 8000TRLP-OAKIPI takes versatility a step further by operating on liquid propane, making it ideal for homes that are not connected to natural gas lines. Along with the IntelliFire Ignition technology, this model ensures exceptional efficiency, making it a premium choice for those who prioritize sustainable energy solutions. The design retains the luxurious oak finish found in its counterparts, ensuring it complements any interior decor seamlessly.

All three models share a range of characteristics that set them apart: a robust construction that promises longevity, an array of customizable options, and built-in safety features that instill confidence in operation. They also offer a variety of venting options, giving homeowners flexibility in installation. With Hearth and Home Technologies’ commitment to quality and innovation, the 8000 series fireplaces provide not just heat, but a captivating focal point for home gatherings.