Hearth and Home Technologies ST42A Outside Air, Firescreen, Clear Space Near the Fireplace

Page 27

B. Outside Air

A source of air (oxygen) is required in order for combustion to take place. Whatever air is consumed by the fi re must be replaced through cracks around windows, under doors, etc. Most newly constructed houses or existing homes fi tted with tightly sealed doors and windows are relatively air tight. In this case, an outside air source must be made available to feed combustion air from outside the home.

An outside air control handle allows you control of the out- side air inlet if your fi replace is equipped with this option. Use of outside air for combustion is highly recommended to conserve heated air within the structure and to provide make up air to keep the fi replace venting properly.

This fi replace will operate correctly only if adequate ventila- tion is provided to allow proper draft to the fi replace sys- tem.

See Figure 9.1 for location and operation.

E. Firescreen

A fi rescreen is always provided to control sparks. It must be closed whenever the fi replace is in use. Glass doors or

rescreens must not be used to hold burning material in- side the fi replace. Only those glass doors specifi cally tested and listed for use with the specifi c fi replace model should be used. Screens should be closed when the glass doors are closed.

WARNING

Fire Risk

Close fi rescreen when burning fi replace.

Do not use fi rescreen or glass doors to hold burning material in fi replace.

Firescreen controls sparks.

Glass may break or burning material may roll out.

CAUTION

Outside air control handles are HOT. Adjust before lighting fi re.

C. Clear Space Near the Fireplace

Combustible materials must not be stored on the hearth ex- tension. Room furnishings such as drapes, curtains, chairs or other combustibles must be at least 4 ft (1.22 m) from the open fronts of the fi replace.

D. Flue Damper

The fl ue damper must be in full open position, and is oper- ated by moving the handle up toward the top of the fi replace. Before lighting the fi re, verify this by looking up from the in- side of the fi replace. Always operate this fi replace with the damper fully open. Please note: Down drafts, obstructions, damaged or poor (wet) fuels can cause smoke spillage.

See Figure 9.1 for location and operation.

WARNING

Asphyxiation Risk

Fire Risk

Open damper to operate fi replace.

Closed damper will over-fi re fi replace and prevent venting of combustion gases.

F. Glass Doors

Most efficient fi replace operation using glass doors is with the doors open. When the doors are open the screen must be closed. Only Hearth & Home Technologies glass doors may be used. See Figure 9.2 for proper glass door opera- tion.

FULLY OPEN

PARTLY OPEN

CORRECT

INCORRECT

FULLY CLOSED

PARTLY CLOSED

CORRECT

INCORRECT

Figure 9.2 Proper Operating Positions of Bi-fold Doors

WARNING

Fire Risk

Smoke Risk

Doors must be fully opened or fully closed when operating fi replace.

Partially opened doors may draw flame, smoke or heat from fi replace.

Heatilator • ST42A • 35038 Rev G • 02/05

27

Image 27
Contents Fire Risk ST42ANumber Homeowner Reference InformationListing Label Information/Location GrateTable of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Asphyxiation Risk Design and Installation ConsiderationsGetting Started Negative PressureMarginal Location Typical Fireplace System Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesMm min ClearancesFrame the Fireplace Sidewalls/SurroundsChimney Requirements Construct the ChaseRisk of Smoke Spillage Installation of FireplaceInstall the Outside Air Kit Sharp Edges Fire Risk Asphyxiation RiskLevel the Fireplace Secure the FireplacePosition the Fireplace Place the Protective Metal Hearth StripsChimney Assembly C,f SL1106 SL1112 SL1118 SL1136 SL1148 Using Offsets/ReturnsAssemble the Chimney Sections Install the Firestop SpacersInstall the Attic Insulation Shield Double-check the Chimney AssemblySecure the Chimney Chimney Termination Complete the EnclosureChase Top Install the Chimney Air Kit required in CanadaInstalling an ST1175 Square Termination Cap Install the Termination CapAccessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1-1980 Finishing Hearth ExtensionHearth Extension Insulation Alternatives, R Value = Finishing Material Glass DoorsMantel General Information Operating InstructionsFlue Damper Outside AirFirescreen Clear Space Near the FireplaceMoisture GrateWood Fuel FirewoodStarting a Fire Understanding Vent Problems TroubleshootingCan’t get a good fire going. What am I doing wrong? Diagnostics and Problem SolvingDiagnostic Questions Solutionsfireplace burns the wood too fast. What can I do? Firebox Refractory Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Disposal of AshesChimney Fire Maintenance Task ListWhen cleaning glass door CleanReference Materials Fireplace DimensionsModel # Description Fireplace ComponentsCatalog # Chimney Components15-1/4 387 mm 25-1/4 641 mm 14-3/4 375 mm Woodburning Termination Cap Shroud TS345 TR342 TR342 / 344 TV TR11 / 11T TR11 / 11T TVTR442 TR442 / 444 TV ST42 Service PartsQty # Description of PartLimited Warranty Contact Information

ST42A specifications

Hearth and Home Technologies ST42A is a highly regarded product in the realm of home heating, known for its excellent combination of functionality, efficiency, and aesthetic appeal. This stylish gas fireplace offers the perfect blend of modern design and superior technology, making it an ideal choice for homeowners seeking both comfort and elegance.

One of the main features of the ST42A is its remarkable heating capacity. With a BTU output ranging from 26,000 to 36,000, it efficiently warms spaces, making it suitable for medium to large living areas. This gas fireplace is designed to deliver heat effectively while maximizing energy efficiency, allowing users to enjoy warmth without incurring excessive energy costs.

The ST42A comes equipped with an advanced electronic ignition system, ensuring reliable startup and operation. This system not only adds convenience but also enhances safety, as it minimizes the risk of gas leaks. The fireplace is designed to operate on natural gas or propane, offering flexibility to homeowners based on their fuel availability and preferences.

In terms of design, the ST42A boasts a contemporary look that fits seamlessly into a variety of interior styles. Its large viewing area, framed by a stylish surround, allows for an impressive flame presentation that serves as a focal point in any room. The variable flame height adjustment feature allows users to customize the ambiance and comfort level, further enhancing the overall experience.

One of the standout technologies in the ST42A is its unique heat distribution system. This feature ensures that warmth is circulated throughout the room, rather than being concentrated in one area, promoting an even temperature distribution. Additionally, the fireplace is equipped with optional blower kits that can enhance air circulation, further improving the efficiency of heat delivery.

Maintenance is another significant consideration with any heating appliance, and the ST42A simplifies this with accessible components and easy cleaning features. The ceramic glass front is designed to resist soot buildup, ensuring a clear view of the flames and reducing the need for frequent upkeep.

Overall, the Hearth and Home Technologies ST42A stands out as a premium choice for those looking to add warmth and style to their home. With its powerful heating capabilities, advanced technologies, and elegant design, it represents an investment in both comfort and aesthetic enhancement for any living space.