Baxi Potterton 24/1.0 operating instructions List of Error Codes, Nrp, Ar+, Arp

Page 18

In the table below: - PCB = Main Control Board, BCU = Burner Control Unit.

 

 

11.0 Error Codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UR = User Reset, AR = Automatic Reset, ARP = Automatic Reset after Power Down

 

 

 

 

 

 

 

 

 

11.1

 

List of Error Codes

 

 

 

 

 

 

 

 

 

 

NOTE: An automatic reset is only done if the fault condition has cleared.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error code: Display

Description

 

 

 

 

Lockout/Reset action

 

 

 

 

 

 

 

 

Eng

Sup

 

10: Outside sensor

Fault outside temp sensor1

 

 

 

 

AR

 

AR

 

 

20: Boiler flow sensor

Fault boiler flow temp sensor

 

 

 

 

AR

 

AR

 

 

40: Boiler return sensor

Fault return temp sensor boiler

 

 

 

 

AR

 

AR

 

 

50: DHW tank sensor

Fault DHW1 sensor

 

 

 

 

AR

 

AR

 

 

60: Room sensor 1

Fault room temp sensor HC1

 

 

 

 

AR

 

AR

 

 

65: Room sensor 2

Fault room temp sensor HC2

 

 

 

 

AR

 

AR

 

 

83: BSB short-circuit

Boiler system bus short-circuit

 

 

 

 

AR

 

AR

 

 

84: BSB address collision

More then 1 room units are assigned to the same HC

 

 

 

 

 

 

 

 

 

 

Assign one of them to HC2 or assign QAA7x not as room unit

 

AR

 

AR

 

85: Radio communication

Communication to radio device interrupted

 

 

 

 

AR•

 

AR•

 

 

91: Data loss in EEPROM

Failure in Class B-SW: Irreparable data loss in EEPROM

 

 

 

 

NRP

 

NRP

 

 

92: Device electronics error

RAM failure, HBC processor register failure, blocking chain

 

 

 

 

 

 

 

 

 

undefined (toggling), safety chain discrepancy.

 

 

 

 

 

 

 

 

 

 

Reset: Press Service Reset within 20 seconds after Power up

 

NRP

 

NRP

 

95: Time of day invalid

The real time clock unit detected corrupted time of day.

 

 

 

 

 

 

 

 

 

96: Minor SW failure

Failure in Class B-SW: Stack overflow or program sequence failure

 

AR

 

AR

 

 

97: SW or HW failure

Failure in EGC-SW which causes non-volatile lock.

 

 

 

 

NRP

 

NRP

 

 

127: Legionella temperature

Legionella temperature not achieved within 48 hours

 

 

 

 

AR+

 

AR+

 

 

157: Boiler Flow Overheat stat

Boiler flow overheat thermostat / safety chain open

 

 

 

 

UR

 

UR

 

 

158: Condensate

Condensate switch of safety chain opened

 

 

 

 

UR

 

UR

 

 

164: Flow

Low flow or faulty flow switch

 

 

 

 

AR

 

AR

 

 

257: Pack sensor

Fault pack temp sensor

 

 

 

 

 

 

 

 

 

258: Pack over- temp

Internal ambient temperature to high

 

 

 

 

AR

 

AR

 

 

259: CJC sensor

Fault cold junction compensation sensor

 

 

 

 

AR

 

 

 

 

261: Loss of Engine flame

No flame after five ignition tries in Engine

 

 

 

 

UR

 

 

 

 

262: Loss of Supplementary flame

No flame after five ignition tries in Supplementary

 

 

 

 

 

 

UR

 

 

263: Engine BCU failure

Multiple communication request of Engine Burner Control Unit

 

 

 

 

 

 

 

unsuccessful.

 

 

 

 

 

 

 

 

 

 

1) Failure caused by BCU

 

 

 

 

ARP

 

 

 

 

 

2) BCU Communication Timeout on Main Control Board

 

 

 

 

AR

 

 

 

 

264: Supp. BCU failure

Multiple communication request of Supp. Burner Control Unit

 

 

 

 

 

 

 

unsuccessful.

 

 

 

 

 

 

 

 

 

 

1) Failure caused by BCU

 

 

 

 

 

 

ARP

 

 

2) BCU Communication Timeout on Main Control Board

 

 

 

 

 

 

AR

 

265: BCU failure

Not supported in Main Control Board

 

 

 

 

 

 

 

 

 

270: excessive temp. diff.

Excessive max temperature difference across the heat exchanger

 

 

 

 

 

 

 

during 5 minutes or excessive limit temperature difference.

 

 

 

 

 

 

 

 

 

If temperature difference fell below (threshold - switching

 

 

 

 

 

 

 

 

 

 

differential boiler): automatic reset

 

 

 

 

 

 

 

 

 

 

- when the maximum setting was exceeded immediately

 

 

 

 

AR

 

AR

 

 

- when the limit value was exceeded after 10 minutes

 

 

 

 

 

 

AR 10’

 

274: Dry fire protection

Flow switch did not close within 4 minutes

 

 

 

 

UR

 

UR

 

 

 

 

 

 

 

 

 

 

278: Max Temp Rise

Maximum flow temperature rise exceeded, automatic reset after

 

 

 

 

 

 

 

10 minutes

 

 

 

 

 

 

AR 10’

 

 

 

 

 

 

 

 

 

 

 

 

 

• After 10 minutes or after down power (ARP)

+ Will clear message if 65°C is achieved - does not inhibit appliance on.

18© Baxi Heating UK Ltd 2010

Image 18
Contents Ecogen 24/1.0 Contents 0086Default 6am 9am, 11am 12pm & 15pm 22pm Quick Reference GuideEasy menu button Important Notes IntroductionDescription POUProgrammable Operator Unit POU ProgrammersGetting Started POU as a Programmable Room Unit PRUSetting the Time Time SettingStep Highlight ‘Time central heating CH1’ Setting the Central Heating TimesProgramming the Central Heating Times Press the Dial KnobDisplay Screen Turn the Dial Knob one click Required time. PressDial to select Setting the DHW Times Programming the Domestic Hot Water TimesTurn the Dial Knob clockwise To highlight ‘Time hot water’ Menu Button Easy Menu Dial Knob Dial Knob. The ‘1st Time OFF’ Time will flash. Turn the DialMode Selection/Temp Adjustment Selecting the Cental Heating ModeFurther Information Adjusting the DHW Tank Temperature Selecting the Domestic Hot Water DHW modeAdjusting the Room temperature set point Room Temperature SetpointHoliday mode Programme LockContents of Other Functions Service/Special operation Selecting Temps / mode CH1Selecting Temps / mode hot water Selecting Diagnostics engineUser reset Resetting the BoilerAutomatic reset Service resetClearances Top 200mm Bottom Left side 5mm Right Side 60mm Front5mm In Operation NRP Error CodesList of Error Codes AR+Engine head control temperature less than 150 degrees C when Call your Installer or Service Engineer as soon as possible Protection & PrecautionFault Indication Care of the BoilerLegislation Installation, Commissioning, Service & RepairBenchmark Commissioning Checklist Contact the Electricity ProviderPage Page Serial Number Date of Installation BaxiBrooks House, Coventry Road, Warwick. CV34 4LL