Natural Gas
Baxi Ecogen 24
G.C.No 41 075 60
This appliance contains a small scale embedded generator (SSEG). Both the District Network Operator and the Electricity Provider must be informed, this is a legal requirement - see section 12.3.
This appliance contains a pressure vessel filled with Helium to 23 bar. Do not strike, drop, drill or puncture the vessel.
Do not unbolt any of the covers or flanges.
The vessel contains no user serviceable parts.
Dispose of safely.
Legionella
If the DHW cylinder has been fitted with a control sensor instead of a thermostat
for increased efficiency, the control will recognise this and automatically initiate an
DHW set point is overridden and the cylinder is heated to 65° C for 10 minutes.
The default time for this action is monday 8am every week.
If the set point has been reduced to say 40° C for safety reasons, the users must
bear in mind that the temperature around this time may be much hotter than usual.
The time of the function may be altered or the action disabled.
The Benchmark Scheme
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
©Baxi Heating UK Ltd 2010 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address:
The Company Secretary, Baxi Heating UK Ltd, The Wyvern Business Park, Stanier Way, Derby, DE21 6BF.
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.
0086
Contents
Section |
| Page |
1.0 | Quick Reference Guide | 3 |
|
|
|
2.0 | Introduction | 4 |
|
|
|
3.0 | The Programmers | 5 |
|
|
|
4.0 | Setting the Time | 6 |
|
|
|
5.0 | Setting the Central Heating Times | 7 |
|
|
|
6.0 | Setting the DHW Times | 9 |
|
|
|
7.0 | Mode Selection/Temp Adjustment | 11 |
|
|
|
8.0 | Contents of Other Functions | 14 |
|
|
|
9.0 | Resetting the Boiler | 16 |
|
|
|
10.0 | Clearance | 17 |
|
|
|
11.0 | Error Codes | 18 |
|
| |
12.0 Care of the boiler | 20 | |
|
|
|
13.0 | Legislation | 21 |
|
|
|
14.0 | Notes | 22 |
|
|
|
Boiler Controls - see opposite page for Operating Quick Reference Guide
2© Baxi Heating UK Ltd 2010