Honeywell AC-140-7, AC-220-7 manual Exit Setup Mode, Setup Outputs Relay Exit

Page 37

2. SETUP (ADVANCED OPTIONS)

T775A/B/M SERIES 2000 CONTROLLER

SETUP

OUTPUTS

RELAY 1

RESET

SCHEDULE

RESET RT

EXIT

Fig. 68. Setup - Outputs - Relay - Exit.

2.4. EXIT Setup Mode

Press the W button to exit the selected relay set up and return to the Outputs menu.

To setup the next relay output go to “2.3.4. Setting up the Relays” on page 26.

If you are finished setting up the relay outputs, press the HOME button to exit Setup mode and return to the home screen display.

M24534 This completes the Setup procedure.

29

62-0254–03

Image 37
Contents Section Introduction FP-4 Freeze Protection KITSection InstallationInstalling the Conduit Control BOX Component Layout and Wiring Diagram Section InstallationOperation Setting the ControllerTroubleshooting Procedures Section TroubleshootingReplacement Parts Section Replacement PartsPER VAN AIR Terms and Conditions of Sale Section WarrantyProduct Description Controller Dimensions Temperature SensorsaAccessories Installation and Setup Before InstallationWiring MountingTemperature Sensor Wiring Wiring Connections AccessTemperature Sensor Wire Type and Size Multiple Parallel SensorsController Wiring Method Controller WiringController Wiring Details Wiring Applications ExamplesDescription of Wiring Terminal Connections Terminal Label Connection Terminal Label Description SensorsWiring for four-stage control 24 Vac input 24 Vac load Wiring for ML7984 valve actuator Wiring for three Series 90 Modutrol Motors Temperature Sensor Calibration Power LossCheckout Foota MΩ/ft Rating 200 ft 500 ft 000 ftInterface Overview Using the LCD Panel InterfaceHome Screen Using the Menus Accessing the MenusSetup Menu Programming, Scheduling, and Summary MenusCooling Mode Setpoint and Differential Heating Mode Setpoint and DifferentialProgramming Setpoint and DifferentialProgramming the T775A/B/M Controller Entering Program ModeProgram Menu for Outputs Sensor Differential or Throttling RangeHEAT/COOL Setback Exiting Program ModeProgram Next Output Mod or Relay Setup Procedure Setup Advanced OptionsEntering Setup Mode Setting up the SensorsUnits F or C Sensor aCalibrate the sensor Label the sensor inputSensor B Exit Sensor a SetupCalibrate LabelLimit Sensor B only HI Limit or LOW Limit Sensor B onlySetting up the Modulating Outputs Setting up the OutputsThrottling Range Sensor B only MIN OUT % Type of output signalIntegral Exit ScheduleUSE Sched OptionsDI Options digital input options MIN OFF minimum off time for all relaysShow RT show run time hours Setting up the Relays Exit Options SetupType standard or floating Floating Relay Menu Derivative modulating/floating relay only Reset RT run time hoursSetup Outputs Relay Exit Exit Setup ModeScheduling Entering Schedule ModeCreating a Schedule SET Date SET TimeDaylight daylight saving time Mon-Fri Schedule Defaults Setting Individual Schedules1. E1 Setpt setpoint for event Exit exit from selected time period settings Exiting Scheduling Mode2. E1 Time time for event 3. E2 Setpoint setpoint for eventErrors and Diagnostics TroubleshootingError Message Diagnostic MessagesEmissions Compliance Safety ComplianceImmunity Compliance FCC Compliance StatementDOC T775A/B/M Series 2000 Controller

AC-220-7, AC-140-7 specifications

The Honeywell AC-140-7 and AC-220-7 are advanced air conditioning units that exemplify modern air conditioning technology, delivering both comfort and efficiency. Designed for varying space requirements, these units cater to both residential and light commercial settings, providing versatile solutions for climate control.

The AC-140-7 model is particularly known for its compact design, making it suitable for smaller spaces without sacrificing performance. It delivers an impressive cooling output, effectively maintaining comfortable indoor temperatures even during the hottest months. The system utilizes a high-efficiency compressor that operates quietly, ensuring minimal disruption to daily activities. Additionally, the AC-140-7 features an advanced air filtration system that helps to improve indoor air quality by capturing dust, allergens, and other particulates.

In contrast, the AC-220-7 is designed for larger spaces, providing robust cooling capacity. It incorporates multiple fan speeds and advanced thermostatic controls, allowing users to customize their cooling experience according to their preferences and requirements. One of the standout characteristics of the AC-220-7 is its energy efficiency, with a high Seasonal Energy Efficiency Ratio (SEER) rating, which is crucial for reducing energy costs while maintaining optimal performance.

Both models are equipped with state-of-the-art technologies, including smart diagnostic features that help users troubleshoot issues quickly and efficiently. This capability not only enhances the user experience but also prolongs the lifespan of the units. Furthermore, these units are easy to install and maintain, with accessible components for service and cleaning.

A critical characteristic of the Honeywell AC-140-7 and AC-220-7 is their environmentally friendly refrigerants, which align with modern environmental regulations. This aspect makes them a responsible choice for environmentally conscious consumers.

In summary, the Honeywell AC-140-7 and AC-220-7 units are excellent examples of innovation in air conditioning solutions. With their combination of efficiency, advanced features, and quiet operation, these models represent a significant investment in comfort and sustainability for any space. Whether cooling a small room or a larger area, Honeywell’s engineering excellence ensures that users enjoy effective climate control tailored to their needs.