Lux Products TX9100E warranty Heating and Cooling, Wait Icon

Page 21

buttons, adjust the clock to the current time, and make sure that the proper AM or PM indication is observed as appropriate. To assist with large adjustments, the clock digits will increment rapidly in either direction if the UP or DOWN buttons are held pressed for more than a few seconds.

HEATING AND COOLING

Basic operation of your heating or cooling system can be obtained by ensuring that the rotary dial is in the RUN position, and simply moving the Temperature Mode switch to either the HEAT or COOL position. Manual adjustment of the set temperature can be performed at any time by using the UP/DOWN buttons. While the words “SET TEMP” are being displayed, you are able to adjust the set temperature to any desired value within the normal operating range.

Prior to being set initially with your custom temperature programs, the thermostat will follow the default Energy Star® approved temperature programs that are preset within the thermostat’s memory. A table of the default heating and cooling programs is shown below:

PERIOD

HEAT MODE

COOL MODE

MORN

6:00 AM 70 °F (21 °C)

6:00 AM 78 °F (26 °C)

DAY

8:00 AM 62 °F (17 °C)

8:00 AM 85 °F (29 °C)

EVE

6:00 PM 70 °F (21 °C)

6:00 PM 78 °F (26 °C)

NITE

10:00 PM 62 °F (17 °C)

10:00 PM 82 °F (28 °C)

WAIT ICON

On the far right edge of the display screen, the words “WAIT” may show up flashing from time to time. This Wait indicator appears if there is currently a demand present for heating or cooling activation, but the minimum off time delay has not yet been satisfied. This provides protection for your heating and cooling equipment, but lets you know that the system will turn on shortly if it is required.

21

Image 21
Contents TX9100E Installation and Operating InstructionsSystem Compatibility Compatible withNot Compatible with Tools Required Thermostat FeaturesSelecting a Location Mount the NEW Thermostat Remove OLD ThermostatWiring Diagram Notes Wiring Information and Diagrams Connecting the WiresPage Typical 24-VOLT, 2 or 3 WIRE, Conventional Typical 24-VOLT, CONVENTIONAL, 1-STAGE, HOT Water Factory RH-RC Jumper Wire Installed Systems with 1 Stage Heat and 1 Stage Cool Heat Factory Supplied RH-RC Customer Supplied Typical 24V, 5 WIRE, Heat Pump Systems RC G Hardware Setup Options Option SwitchesGAS/ELEC. FAN Operation System Mode RecoveryDelay Battery Monitor Completing the InstallationScale Reset Mode SwitchesFront Panel Items Rotary Dial Push ButtonsOperating Instructions SET DAY/TIMEWait Icon Heating and CoolingTemperature Hold Temperature OverrideDisplay Backlight Emergency Heat Heat Pump Configuration OnlyAdvanced Features Swing and Offset SettingsAIR Filter Monitor Degrees F Programmable Keypad Lock User Temperature Calibration536PM 72 F Page Programming Quick Copy FeatureSET Heat Program SET Cool Program536PM 72 F Batteries and MaintenanceTechnical Assistance Warranty 536PM 72 F