save energy in some cases. There is only one Swing setting, and this determines the cut-in and cut-out points for both the first and second stages (if present), and affects both heating and cooling. To change the Swing setting, ensure that the System Mode switch is in the OFF position and the rotary dial is in RUN. Press the HOLD button for at least 2 seconds. The words “SET:” and “SWING” will appear on the screen with a single digit shown. Use the UP/DOWN buttons to change the number value between 1 and 9 (0.25F to 2.25F, in 0.25F degree increments). Number 1 is the default setting. Press the NEXT button to accept the swing setting and proceed to the OFFSET setting.
Cut-In / Cut-Out
(1st Stage)
69Swing
Setting=
#2 (+/- 0.5˚F)
68
67
66
65 DEGREES (F)
Offset ** Setting= 4˚F degrees
(2nd Stage) **
Cut-In / Cut-Out
**= Only applies if a second heat stage is present