Bryant T2SNAC01 Install Thermostat, Set Thermostat Configuration, Electrical Operation Hazard

Page 2

Table 1 – Model Selection and Wiring Diagram Chart

OUTDOOR UNIT

AIR CONDITIONER

HEAT PUMP

 

1 Speed

1 Speed

 

 

 

 

 

 

1--- Stage Furnace

Model AC See Fig.

---

 

 

 

 

 

2--- Stage Furnace

Model AC See Fig.

 

Model HP See Fig.

---

Typical Fan Coil

Model AC See Fig.

 

Model HP See Fig.

Model HP See Fig.

 

 

 

 

 

Variable--- Speed Fan Coil (FK4D,

Model AC See Fig.

 

Model HP See Fig.

Model HP See Fig.

FV4, 40FK)

 

 

 

 

 

 

 

 

 

 

T2SN

Install Thermostat

!WARNING

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label.

1.Turn OFF all power to unit.

2.If an existing thermostat is being replaced:

a.Remove existing thermostat from wall.

b.Disconnect wires from existing thermostat, 1 at a time. Be careful not to allow wires to fall back into the wall.

c.As each wire is disconnected, record wire color and terminal marking.

d.Discard or recycle old thermostat.

NOTE: Mercury is a hazardous waste and MUST be disposed of properly.

3.Open thermostat (mounting base) to expose mounting holes. The base can be removed to simplify mounting. Snap apart carefully to separate mounting base from remainder of thermostat.

NOTE: If thermostat will not separate, insert a small screwdriver into top slots for ease of opening.

4.Route thermostat wires through large hole in mounting base. Level mounting base against wall (for aesthetic value only - thermostat need not be leveled for proper operation) and mark wall through 2 mounting holes.

5.Drill two 3/16” (5mm) mounting holes in wall where marked.

6.Secure mounting base to wall with 2 anchors and screws provided, (additional anchoring holes available for more se- cure mounting if needed) making sure all wires extend through hole in mounting base.

7.Adjust length and routing of each wire to reach proper ter- minal and connector block on mounting base with 1/4” (6mm) of extra wire. Strip only 1/4” (6mm) of insulation from each wire to prevent adjacent wires from shorting together when connected.

8.Match and connect equipment wires to proper terminals of the connector blocks. (See Table 1.)

!CAUTION

ELECTRICAL OPERATION HAZARD

Failure to follow this caution may result in equipment damage or improper operation.

Improper wiring or installation may damage the thermostat Check to make sure wiring is correct before proceeding with installation or turning on unit.

9.Push any excess wire into wall and against mounting base. Seal hole in wall to prevent air leaks. Leaks can affect operation.

10.Snap case back together.

11.Close thermostat assembly making sure pins on back of circuit board align with sockets in connector.

12.Turn ON power to unit.

NOTE: If a common wire has not been connected, two AA batteries must be used to power the thermostat.

Make sure the customer is informed about changing the batteries every 12 months, if a common wire is not available.

If a common wire is connected, then batteries are not needed for any reason. Batteries may be installed if desired but the thermostat will not draw power from them.

Set Thermostat Configuration

Configuration options are intended to be selected at installation and are normally not modified by the home owner. These options are not discussed in the Homeowner’s Guide and therefore must be made as part of the installation. A special procedure allows entry into the configuration mode. The thermostat will automatically exit this mode if no button is pressed for 3 minutes. While in the configuration mode, up to 14 option choices can be made:

Option 01: Anticipator setting

Option 02: Clean filter setting

Option 03: Fahrenheit or Celsius selection

Option 04: Enable fan (G) on with W output

Option 05: HP / AC

Option 07: Enable zoning

Option 10: O (reversing valve) ON with Heat or Cool (present on Heat Pump models only)

Option 13: Room temperature offset adjustment

Option 15: Enable AUTO mode

Option 18: Backlight Configuration

Option 19: Equipment Present

Option 21: Keypad Lockout

An explanation for each of these and how to enter the configuration mode follows.

2

Image 2
Contents Power Models Safety ConsiderationsInstallation Thermostat LocationModel Selection and Wiring Diagram Chart Install ThermostatSet Thermostat Configuration Electrical Operation HazardTo enter the configuration mode While in configuration modeOption 18 Backlight Configuration Option 13 Room Temperature OffsetOption 15 Auto Mode ON/OFF Selection Option 10 O Reversing Valve on with Heat or Cool SelectionCheck Thermostat Operation Wiring Diagram Notes HP Thermostat with Fan CoilOperational Information Catalog No. IIT2SNAC---01 Congratulations Common Terms

T2SNAC01, T2SNHP01 specifications

The Bryant T2SNHP01 and T2SNAC01 heat pump and air conditioner systems are designed to provide efficient heating and cooling solutions for residential environments. These systems represent Bryant's commitment to quality, durability, and energy efficiency, making them excellent choices for homeowners seeking reliable climate control.

The Bryant T2SNHP01 is a high-efficiency heat pump system, which can provide both heating and cooling. It features advanced two-stage heating and cooling capabilities, ensuring balanced temperature control and consistent comfort. This model employs a variable-speed compressor, which allows it to adjust its output based on the home's specific requirements. This adaptability not only enhances comfort levels but also leads to significant energy savings by operating efficiently across varying conditions.

One of the standout features of the T2SNHP01 is its SEER (Seasonal Energy Efficiency Ratio) rating. With ratings as high as 16, this heat pump can significantly reduce energy consumption compared to lower-rated systems, leading to lower utility bills. The system operates quietly as well, thanks to its insulated compressor and fan design, which minimizes sound levels for a more pleasant home environment.

On the other hand, the Bryant T2SNAC01 serves as a highly efficient air conditioning unit designed to maximize cooling performance. Similar to its heat pump counterpart, the T2SNAC01 utilizes two-stage cooling. This dual cooling capability allows for optimal performance during both extreme temperatures and more moderate weather conditions. Like the T2SNHP01, this model also boasts impressive SEER ratings, offering efficiency that meets or exceeds industry standards.

Both systems incorporate the latest in eco-friendly refrigerant technology, using R-410A refrigerant, which is known for its lower environmental impact compared to older refrigerants. Additionally, both units are built with durable materials aimed at withstanding various weather conditions, ensuring longevity and reliability.

Another key characteristic is the smart technology integration available in both models. Homeowners can take advantage of Bryant's Smart Thermostat compatibility, allowing for remote control and programming via smartphones, enhancing user convenience and control over home climate.

In summary, the Bryant T2SNHP01 and T2SNAC01 provide efficient, reliable heating and cooling solutions. With their high SEER ratings, advanced technologies, eco-friendly refrigerants, and smart capabilities, these systems are well-suited for homeowners who prioritize comfort and energy savings in their climate control choices.