Bard W3LV1, W6RV1, W3RV1, W5LV1, W6LV1, W5RV1 Electrical Specifications W*RV / W*LV Series

Page 21

Page

Manual

21 of 23

2100-538E

TABLE 3

Electrical Specifications — W*RV / W*LV Series

 

Electrical

 

 

 

 

 

 

 

 

 

Dual Circuit

 

 

 

 

 

 

 

 

 

 

 

 

Rating:

No. Field

3 Minimum

1 Maximum

2 Field

 

 

3 Minimum

 

 

1 Maximum

 

 

2 Field

 

 

2 Ground

 

 

Volts

2 Ground

 

 

Circuit

 

 

 

 

Power

 

 

 

Model

Power

Circuit

Overcurrent

Power

 

 

 

Overcurrent Protection

 

 

 

Wire Size

 

Hz

Wire

 

 

Ampacity

 

 

Wire Size

 

 

 

 

Circuits

Ampacity

Protection

Wire Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

 

Ckt. A

 

Ckt. B

 

Ckt. C

Ckt. A

 

Ckt. B

 

Ckt. C

Ckt. A

Ckt. B

Ckt. C

Ckt. A

Ckt. B

 

Ckt. C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W3RV1 / W3LV1-R0Z

230/208-60-1

1

28

35

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

R05

1

54

60

6

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

220/200-50-1

 

 

 

 

 

R10

1 or 2

80

80

4

8

54

 

26

 

N/A

60

 

30

 

N/A

6

10

N/A

10

10

 

N/A

 

 

 

 

 

 

W3RV1 / W3LV1-S0Z

230/208-60-3

1

19

30

10

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

S06

1

37

40

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

220/200-50-3

 

 

 

 

 

S09

1

46

50

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

 

 

 

 

 

 

W3RV1 / W3LV1-T0Z

460-60-3

1

12

15

14

14

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

T09

1

25

25

10

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

400-50-3

 

 

 

 

 

T12

1

29

30

10

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

 

 

 

 

 

 

W5RV1 / W5LV1-R0Z

230/208-60-1

1

39

60

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

R10

1 or 2

91

100

3

8

39

 

52

 

N/A

60

 

60

 

N/A

8

6

N/A

10

10

 

N/A

220/200-50-1

 

 

 

 

 

R20

1 or 3

143

150

10

6

39

 

52

 

52

60

 

60

 

60

8

6

6

10

10

 

10

 

 

 

 

 

 

W5RV1 / W5LV1-S0Z

230/208-60-3

1

28

40

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

S09

1

55

60

6

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

220/200-50-3

 

 

 

 

 

S18

2

N/A

N/A

N/A

N/A

55

 

28

 

N/A

60

 

30

 

N/A

6

10

N/A

10

10

 

N/A

 

 

 

 

 

 

W5RV1 / W5LV1-T0Z

460-60-3

1

18

25

10

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

T09

1

32

35

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

400-50-3

 

 

 

 

 

T18

1

41

45

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

 

 

 

 

 

 

W6RV1 / W6LV1-S0Z

230/208-60-3

1

42

60

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

S09

2

N/A

N/A

N/A

N/A

42

 

28

 

N/A

60

 

30

 

N/A

8

10

N/A

10

10

 

N/A

220/200-50-3

 

 

 

 

 

S18

2

N/A

N/A

N/A

N/A

42

 

55

 

N/A

60

 

60

 

N/A

8

6

N/A

10

10

 

N/A

 

 

 

 

 

 

W6RV1 / W6LV1-T0Z

460-60-3

1

22

35

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

T09

1

36

45

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

400-50-3

 

 

 

 

 

T15

1

45

50

8

10

N/A

 

N/A

 

N/A

N/A

 

N/A

 

N/A

N/A

N/A

N/A

N/A

N/A

 

N/A

 

 

 

 

 

 

1Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.

2 Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes.

3 These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing.

Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway.

* Top outlet supply option is available only factory installed and only on the selected models.

IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes.

Image 21
Contents Bryan, Ohio Bard Manufacturing Company, IncContents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsWall Mount General Information Shipping DamageGeneral Filters Duct WorkFresh AIR Intake Condensate DrainInstallation Instructions Wall Mounting InformationMounting the Unit Supply Return W3RV1 Right Unit Left UnitMountinginstructions W5RV1, W5LV1, W6RV1, W6LV1 W3RV1, W3LV1, W5RV1, W5LV1, W6RV1, W6LV1 Electric Heat ClearanceIf Required Wall Mounting InstructionsFree AIR Flow Ducted Supply No Duct Return AT Unit Common Wall Mounting InstallationsWiring LOW Voltage Wiring Wiring Main PowerTAP Range 240 253 208 220Topping OFF System Charge Safety PracticesHigh Pressure Switch Important Installer NoteThree Phase Scroll Compressor Start UP Information Phase MonitorModes of Operation Sequence of OperationCooling Sequence LEAD/LAG SequenceCompressor Control Module Pressure Service PortsFAN Blade Setting Dimensions TroubleshootingRemoval of FAN Shroud Refrigerant Charge23.9 26.7 29.4 32.2 35.0 37.8 40.6 43.3 46.1 48.9 51.7 55.0 Cooling Pressure TableElectrical Specifications W*RV / W*LV Series Recommended Airflow Maximum ESP of Operation Electric Heat onlyElectric Heat W3R/LV W5R/LV W6R/LV Vent & Control Options