Bard W6RV1 Free AIR Flow Ducted Supply No Duct Return AT Unit, Common Wall Mounting Installations

Page 12

FIGURE 7

COMMON WALL MOUNTING INSTALLATIONS

RAIN

 

RAIN

FLASHING

RAFTERS

FLASHING

 

 

 

FINISHED CEILING SURFACE

 

 

SUPPLY AIR DUCT

 

 

W/ GRILLE

 

 

RETURN AIR

 

 

OPENING W/ GRILLE

 

OUTSIDE

 

OUTSIDE

WALL

 

 

WALL

 

 

SUPPLY DUCT MAY BE LOCATED IN AN ATTIC OR BELOW CEILING RAFTERS AS SHOWN

RAFTERS

SUPPLY AIR DUCT

FINISHED CEILING SURFACE

RETURN AIR

OPENING W/ GRILLE

FREE AIR FLOW

DUCTED SUPPLY

NO DUCT

RETURN AT UNIT

SUPPLY DUCT MAYBE LOCATED IN AN ATTIC

OR BELOW CEILING RAFTERS AS SHOWN

RAIN

 

RAIN

FLASHING

 

 

FLASHING

 

RAFTERS

 

 

 

SUPPLY AIR DUCT

 

 

FINISHED

 

 

CEILING SURFACE

 

 

RETURN AIR

 

 

SPACE

 

 

WALL SLEEVE

 

 

FALSE WALL

 

OUTSIDE

RETURN AIR GRILLE

 

 

OUTSIDE

WALL

 

WALL

 

 

FALSE WALL INSTALLATION

SUPPLY DUCT MAYBE LOCATED IN AN ATTIC OR BELOW CEILING RAFTERS AS SHOWN

RAFTERS

SUPPLY AIR DUCT

LOWERED

CEILING SUPPLY AIR

GRILLE

 

FINISHED CEILING

CLOSET WALL

SURFACE

 

WALL

 

SLEEVE

 

RAISED FLOOR

RETURN AIR

RETURN AIR

GRILLE

 

CLOSET INSTALLATION

MIS-550 B

Manual

2100-538E

Page

12 of 23

Image 12
Contents Bard Manufacturing Company, Inc Bryan, OhioContents Getting Other Information and Publications For More INFORMATION, Contact These PublishersWall Mount General Information Shipping DamageGeneral Duct Work FiltersFresh AIR Intake Condensate DrainInstallation Instructions Wall Mounting InformationMounting the Unit Right Unit Left Unit Supply Return W3RV1Mountinginstructions W5RV1, W5LV1, W6RV1, W6LV1 Electric Heat Clearance W3RV1, W3LV1, W5RV1, W5LV1, W6RV1, W6LV1Wall Mounting Instructions If RequiredCommon Wall Mounting Installations Free AIR Flow Ducted Supply No Duct Return AT UnitWiring Main Power Wiring LOW Voltage WiringTAP Range 240 253 208 220Safety Practices Topping OFF System ChargeImportant Installer Note High Pressure SwitchThree Phase Scroll Compressor Start UP Information Phase MonitorSequence of Operation Modes of OperationLEAD/LAG Sequence Cooling SequencePressure Service Ports Compressor Control ModuleTroubleshooting FAN Blade Setting DimensionsRemoval of FAN Shroud Refrigerant ChargeCooling Pressure Table 23.9 26.7 29.4 32.2 35.0 37.8 40.6 43.3 46.1 48.9 51.7 55.0Electrical Specifications W*RV / W*LV Series Recommended Airflow Maximum ESP of Operation Electric Heat onlyElectric Heat Vent & Control Options W3R/LV W5R/LV W6R/LV