Bard W5RV1, W6RV1, W3RV1, W5LV1, W3LV1, W6LV1 Wall Mounting Instructions, If Required

Page 11

FIGURE 5

WALL MOUNTING INSTRUCTIONS

SEE FIGURES 3A & 3B – MOUNTING INSTRUCTIONS

WALL STRUCTURE

 

 

FACTORY SUPPLIED

 

RAIN FLASHING.

 

MOUNT ON UNIT

 

BEFORE INSTALLATION

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

DUCT

OPENING

OPENING

 

RETURN AIR

RETURN AIR

RETURN AIR

OPENING

OPENING

OPENING

 

 

WOOD OR STEEL SIDING

BOTTOM MOUNTING

 

 

BRACKET. MOUNT ON

 

 

 

 

 

 

WALL BEFORE

 

 

 

INSTALLING UNIT.

 

CONCRETE BLOCK WALL INSTALLATION

WOOD FRAME WALL INSTALLATION

SIDE VIEW

MIS-548 A

FIGURE 6

WALL MOUNTING INSTRUCTIONS

ATTACH TO TOP

PLATE OF WALL

1.000" CLEARANCE ALL AROUND DUCT

IF REQUIRED

INTERIOR FINISHED WALL OVER FRAME

SEE UNIT DIMENSIONS, FIGURE 2, FOR ACTUAL DIMENSIONS.

E + 1.000

 

B

 

 

1.000

SUPPLY DUCT

A

OPENING

 

 

1.000" CLEARANCE

 

 

I

 

 

 

 

 

ALL AROUND DUCT

 

 

 

 

IF REQUIRED

 

 

 

 

 

RETURN DUCT

C

 

 

OPENING

 

 

 

 

 

 

EXTERIOR FINISH WALL

 

 

 

 

OVER FRAME

 

 

K

 

 

 

 

 

 

 

C

 

 

 

2 x 6

L

 

 

 

 

 

FRAMING MATERIAL

 

 

THIS STRUCTURAL MEMBER

2 x 4'S, 2 x 6'S &/OR

 

 

ATTACH TO BOTTOM

 

LOCATED TO MATCH STUD

STRUCTURAL STEEL

 

PLATE OF WALL

 

SPACING FOR REST OF WALL.

 

 

MIS-549 A

 

 

A SECOND MEMBER MAY BE

 

 

 

REQUIRED FOR SOME WALLS.

Manual

2100-538E

Page

11 of 23

Image 11
Contents Bryan, Ohio Bard Manufacturing Company, IncContents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsGeneral Wall Mount General InformationShipping Damage Condensate Drain Duct WorkFilters Fresh AIR IntakeMounting the Unit Installation InstructionsWall Mounting Information Supply Return W3RV1 Right Unit Left UnitMountinginstructions W5RV1, W5LV1, W6RV1, W6LV1 W3RV1, W3LV1, W5RV1, W5LV1, W6RV1, W6LV1 Electric Heat ClearanceIf Required Wall Mounting InstructionsFree AIR Flow Ducted Supply No Duct Return AT Unit Common Wall Mounting Installations240 253 208 220 Wiring Main PowerWiring LOW Voltage Wiring TAP RangeTopping OFF System Charge Safety PracticesPhase Monitor Important Installer NoteHigh Pressure Switch Three Phase Scroll Compressor Start UP InformationModes of Operation Sequence of OperationCooling Sequence LEAD/LAG SequenceCompressor Control Module Pressure Service PortsRefrigerant Charge TroubleshootingFAN Blade Setting Dimensions Removal of FAN Shroud23.9 26.7 29.4 32.2 35.0 37.8 40.6 43.3 46.1 48.9 51.7 55.0 Cooling Pressure TableElectrical Specifications W*RV / W*LV Series Electric Heat Recommended AirflowMaximum ESP of Operation Electric Heat only W3R/LV W5R/LV W6R/LV Vent & Control Options