5. INPUT DEALER CONTACT INFORMATION

During thermostat operation, the two multi-function buttons are labeled INFO and MENU. When the INFO button is pressed, the thermostat will display the humidity and temperature sensed by the AHC (if an AHC has not been installed the Aprilaire logo screen will appear), then the thermostat will display the thermostat model number and contact information. At installation, the contact information is blank and only the thermostat model number appears. You have the option of inputting this contact information with the name and number of your company. Twenty (20) characters are available for your company name. Space for a telephone number, including area code, is available.

To change the contact information:

1.Make sure the thermostat is in the OFF mode.

2.Press and hold both the ▲ and ▼ buttons for 3 seconds.

– The display will show the ADV. SETTINGS MENU.

3.Use the ▲ or ▼ button to highlight “INPUT DEALER INFO” and press the SELECT button. This enters the company name screen.

4.To cancel, press the BACK button. This returns to the ADV. SETTINGS MENU. You must be at the first position when pressing the BACK button to return to the

ADV. SETTINGS MENU.

5.To delete a character, press the BACK button.

6.To enter a letter in the name of the company, use the

or ▼ buttons to scroll through the available characters. Press the SELECT button to enter the character. For spaces, press SELECT.

7.To finish and go to the company number screen, repeatedly press SELECT until all remaining characters have been filled with spaces, then press SELECT again.

8.To delete a number, press the BACK button.

9.To enter a number, use the ▲ or ▼ buttons to scroll between the available characters. Press the SELECT button to enter the character. The full 10-digit telephone number must be entered.

10.To finish, press the SELECT button after entering the 10th digit.

- 33 -

Image 37
Contents Instructions Table of Contents Check Cooling Operation CustomizeSafety Instructions Model 8570 Specifications Two-Stage Furnace/AC Wire RequirementsRadiant 1st Stage Heat Single-Stage Heat Pump Two-Stage Heat PumpKeep the thermostat 18 from an outside wall Select a Mounting LocationOpen the Thermostat Mount the Thermostat Base to the Wall AHC Set to HP when installed with heat pumps Run a cable with the correct number of wires Wire the Thermostat to the Hvac EquipmentDiagram 1 Single-Stage Furnace and AC Diagram 2 Two-Stage Furnace and AC Diagram 3 Two-Stage Roof Top Unit Diagram 4 Boiler with AC Page Diagram 6 Single-Stage Heat Pump Diagram 7 Two-Stage Heat Pump Mount above anticipated snow line Mount the outdoor temperature sensor see Figure163.8 230.6117.6 85.4IDS ODT CIR GND Mount the AHC and its outdoor temperature sensor Optional Install AN Automatic Humidifier Control AHC+ I- R C H ODT Mount the indoor temperature sensor IDS ODT CIR GND Thermostat Startup Stand Alone Applications From the Main Screen, press the Info button Check FAN OperationTroubleshooting AHC Connection Check Heating Operation Troubleshooting Heating Operation Thermostat does not call for cooling Troubleshooting Cooling OperationTo Cool and make a call for cooling Check Emergency Heat Operation Heat Pumps Only Troubleshooting Emergency Heat OperationTo Emergency Heat and make a call for heat Differential Customize the Application SettingsDisplay will show the ADV. Settings Menu Progressive RecoveryOffset Range is 0F to 40F Balance Points Heat Pumps onlyTo delete a character, press the Back button Input Dealer Contact InformationTo delete a number, press the Back button Blower Extension for Humidity Control Press the Menu button Press the Call Dealer button Press the Reset buttonDP 10006198 B2203358B BOX 1467 MADISON, WI