INSTALLATION
See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances.
RESIDENTIAL STANDARD | MANUFACTURED (MOBILE) HOME STANDARD |
Using 6” (152 mm) Diameter Single Wall Con- | Using 6” (152 mm) Diameter Type |
nector Pipe. Not Approved For Manufactured |
|
(Mobile) Homes. |
|
IMPORTANT NOTES:
•Minimize the use of elbows (30°, 45° or 90°) - Offsets in the venting system are very restrictive and will inhibit the draft (i.e. You will lose approximately 5 feet of effective draft for every 90 degrees of direction change). This appliance requires 12 to 15 feet of effective draft for optimum performance (see Draft Requirements on page 10).
•First section of pipe must be vertical - Use as much straight verti- cal pipe directly above the appliance as possible before using an elbow (a 2’ to 3’ initial vertical rise is suggested).