TROUBLESHOOTING

SMOKES OUT FUEL DOOR WHEN OPEN (see )

1.The primary air control is closed.

2.The chimney is too cool. Set the primary air control on "HIGH" for a few minutes before opening the fuel door.

3.Excess creosote will not only restrict your draft but it will create a risk of a creosote fire. Strictly adhere to mainte- nance requirements as outlined in this manual. If excess creosote has built up on the inside of the firebox sides and door, burn a small hot fire at intervals that are more frequent with air control on HIGH for a few minutes.

4.Deposits may have built up in the chimney and are re- stricting the draft, or the spark arrester on top of the chimney may be plugged.

5.Chimney diameter too large or too small to provide ade- quate draft.

6.The house is too airtight (usually takes 20 to 30 minutes for problem to appear as stove lowers air pressure in house). Crack a window open or provide an outside source of air near stove.

7.Insufficient vertical height to chimney to achieve ade- quate draft.

DOES NOT PRODUCE ENOUGH HEAT ()

1.Using green or insufficiently cured wood.

2.Excessive draft.

3.High ceilings (heat rises quickly, but can be recirculated by a well-placed ceiling fan with a winter/summer switch).

4.The area to heat is too large (square foot heating esti- mates are based on "average" climates and home de- sign).

5.There is an obstruction in the chimney. The chimney or chimney cap is restricted by creosote preventing enough draw to sustain a "high" heat output rate.

DOES NOT MAINTAIN A FIRE ()

1.Soft wood does not burn as long or as well as seasoned hardwood resulting in a short burn time.

2.Wood size too small. Burns at too rapid a rate.

3.The gasket seal on the fuel door or glass is leaking air. Repair or replace it if necessary.

4.Excessive Draft. There may be an obstruction in the chimney.

BACKPUFFING ()

1.Downdraft in the chimney (a special wind cap may be needed).

2.The house is too air tight (ventilation is needed).

3.Insufficient vertical height to chimney to achieve ade- quate draft.

ODORS

1.Creosote accumulation in firebox (brush out on next cleaning).

2.Chimney downdraft when stove is not operating (close the primary air control).

3.Paint curing on first several burns.

DIRTY GLASS ()

1.Poor draft conditions.

2.Long burn periods at low draft settings.

3.Burning wet, pitchy or spongy wood.

4.Poorly arranged logs (too close to glass).

() Draft problems; if installing into a larger flue, it may be necessary to use a full length liner to achieve adequate draft for the appliance. A draft gauge should read a minimum of .05" w.c. (inches water column) not to exceed .07" w.c. for optimum per- formance (See Draft Requirements, page 9).

PAGE 17

Image 17
Contents 775000M, Rev. G, 12/03 EPA Certified Wood Burning Stove Retain These InstructionsReference Important Warnings Table of Contents Selecting a Location Planning Your InstallationSmoke Detectors Combustible Wall Clearance Corner Installation Parallel Alcove ClearanceAlcove Clearances Optional Arch TreatmentFloor Protection Reduced Masonry Structure Clearance AlcoveStandard Parallel Hearth PAD Shown Protected Wall ClearanceSecuring the Stove to the Floor InstallationManufactured Mobile Homes Only Grounding StoveChimney Inspection Acceptable Connector Pipe for INSTALLA- TionsTypes of Chimneys 2’ by 10’ Rule for Vent Termination Chimney Height RequirementsDraft Requirements Draft Test ProcedureImportant Notes Residential Standard Manufactured Mobile Home StandardPenetration Solid-Pak chimney section shall be flush with the insideCare and OPERATI0N Product Features and ControlsPrimary AIR Control Fuel Door Door OperationHOW to Start and Maintain a Fire USE Control Settings That Work for YOUCare and Operation BREAK-IN PeriodFuel MaintenanceCleaning Blower Intake Reinstall Baffle BrickDoor and Glass Gaskets Servicing GlassTroubleshooting Overfiring Damage Specifications Model 1400HT Description Primary AIR Draft Module Door AssemblyHandle Assembly P/N LB-102214 Stove-Stat Kit Outside Air Floor Duct OAFD-RBlower Kit SAFETY/LISTING Label EPA Label Ownership Records Service and Maintenance LOGWest Taft Avenue Orange, CA