LG Electronics LP091HEM-Y8 manual Place the top cover assembly back into the unit

Page 26

7.Remove the screw that attaches the electric heater wire to the side of the indoor fan housing.

8.Remove the 3 screws which fasten the top cover assembly.

Figure 33

9.Position water spraying plastic tube into the electric heater cover. Make sure that the three pairs(total of six) of plastic tongues snap into the corresponding metal slots of the heater frame as shown in fig. 34. Then install one of the three rubber elbows(ref. fig. 38) at the inlet of the spraying tube and through the rubber grommet.

Figure 34

10. Place the top cover assembly back into the unit.

11.Install tube #1 and tube #2 (ref. fig. 38) on the pump assembly using the rubber elbows as shown in fig. 35.

Figure 35

12.Position pump assembly to the basepan as shown in fig. 36 and fasten the pump bracket to the basepan using the three screws provided.

Figure 36

13.Insert tube #2 of the pump assembly through the plastic grommet of the sheet metal partition as shown in fig. 37. Then connect the end of tube #2 to the plastic elbow coming out of the inlet of the spraying tube.

Figure 37

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 26 -

Only for training and service purposes

LGE Internal Use Only

 

Image 26
Contents SVC Manual Specification LGE Internal Use OnlyFeatures and Benefits Sleeve and the Rear GrilleTemperature limits Door Switch/Occupancy SensorOutdoor Air Temperature Switchover Quick Heater RecoveryVentilation Control LocationsOperation Electric Heating Model Removing the Front Grille Temperature LimitingAdditional Controls Additional ControlsEnergy Saver Molex Housing SpecREMOTE/LOCAL Control Front Desk ControlFront Grille Disassembly InstructionsMechanical Parts Control BOX AIR Handling Parts Electric Heater Electric Heater Model onlyCross Flow FAN Axial FANOutdoor Motor Electrical PartsShroud CompressorPower Cord 6 P.C.BEvaporator Refrigeration CycleCondenser Capillary TubeLGE Internal Use Only Pulling Vacuum Dimension of air conditioner InstallationHOW to Install the Unit Dimension of sleeve assembly optionalGeneral Wall Sleeve InstallationWall Case Installation Data Preparation of the Front Grille Installation of Wall Case in Wall OpeningAs shipped, the LG wall sleeve is ready for installation Preparation of the Wall Case for All Types of ConstructionLGE Internal Use Only Sub-Base Connected Unit Installation Electrical Data for 230/208V Model Electrical Safety Electrical Requirements 208, 230, and 208/230 Volt UnitsControl Panel Key Lock Field Installed AccessoriesInstallation DescriptionHazardous Voltage Condensate Disposal Pump Kit InstallationPart No AYSB2101 Place the top cover assembly back into the unit Spraying Architecture Grille Aluminum Single Pack Architectural GrillePart No AYDR101 Drain InstallationCondensate Drain kit Outdoor Drain Kit Installation Outdoor Drain Kit InstallationLeveling Legs Indoor Drain Kit InstallationChecklist Part No AYLL101Leveling Leg Assembly Leveling Leg Assembly Installation on Wall SleevePart No AYAGALA01 Hard Wire KitJunction Box Kit Installation and Wiring Procedure Use Copper Conductors Only208/230 Volt Units Volt UnitsRemote Escutcheon Kit Part No AYRE110Subbase Part No AYSB1101 230/208V 20A AYSB2101 230/208V 30ASkirting Hole Location Right Cover Assembly After wiring is complete, mount covers a and F toTo each installation instruction for that accessory Subbase with provided screws. FigurePiping System Troubleshooting GuideOutside Dimensions 066mm 406mm 505mmTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits 208/230V 187V 253VComplaint Cause Remedy Th3 Thermistor for outdoor Air temperature Piping DiagramsTh2 Thermistor for Evaporator pipe temperature Th4 Thermistor for Condenser pipe Air temperatureSchematic Diagram CN-NNExploded View 435300BJanuary