State Industries GP6 50 instruction manual LED Status Problem Solution

Page 36

#

7

8

9

10

11

12

13

14

15

16

LED STATUS

PROBLEM

 

SOLUTION

 

 

Self diagnostic check has detected

1

Turn the power off for 10-20 seconds then on again to

 

 

 

 

 

clear these error codes.

 

 

 

 

 

a problem with the gas valve driver

 

 

 

 

 

 

 

circuit, internal microprocessor, or

2

If any of these error codes persist or cannot be cleared

 

 

other internal circuits.

 

 

 

- replace the gas control valve/thermostat.

 

 

 

 

 

 

 

1

Turn the power off for 10-20 seconds then on again to

 

 

 

 

 

The gas control valve/thermostat

 

clear these error codes.

 

 

 

 

 

has sensed main burner flame out

 

 

 

 

of proper sequence.

2

Replace the gas control valve/thermostat if this error

 

 

 

 

 

 

code persists.

 

 

Water temperature in the tank has

1

Turn the power off for 10-20 seconds then on again to

 

 

 

clear these error codes.

 

 

exceeded 195° F and has activated

 

 

 

 

 

 

 

the ECO (energy cut off) high

2

Replace the gas control valve/thermostat if the error

 

 

temperature limit.

 

 

 

code persists.

 

 

 

 

 

 

 

1

Press and release both temperature adjust buttons

 

 

Self diagnostic check has detected

 

several times - cycle water heater power off and on.

 

 

 

 

 

that one or both of the temperature

 

 

 

 

adjust buttons are stuck.

2

Replace the gas control valve/thermostat if the error

 

 

 

 

 

 

code persists.

 

 

Self diagnostic check has detected

1

Turn the power off for 10-20 seconds then on again to

 

 

the water temperature sensor

 

clear these error codes.

 

 

 

 

 

(located in the control valve's

 

 

 

 

immersion probe) is either open or

2

Replace the gas control valve/thermostat if the error

 

 

 

 

shorted.

 

code persists.

 

 

 

1

Turn off power to the water heater. Ensure black

 

 

Self diagnostic check has detected

 

resistor wire is not cut, missing, and is installed

 

 

 

between pins 3 & 4 of ignitor assembly plug. Replace

 

 

a problem with black resistor wire

 

 

 

 

ignitor assembly if damaged or defective.

 

 

on the ignitor assembly plug;

 

 

 

 

 

 

 

resistor wire is open or shorted.

2

Replace the gas control valve/thermostat if the error

 

 

 

 

 

 

 

code persists.

 

 

Self diagnostic check has

1

Turn off power to the water heater.

 

 

 

 

 

 

determined resistance of the black

2

Replace the igniter assembly plug.

 

 

resistor wire on ignitor assembly

 

 

 

 

plug is not within tolerance.

3

Replace the gas control valve/thermostat if the error

 

 

 

 

code persists.

 

 

 

1

Ensure air pressure switch hose is not kinked or

 

 

 

 

clogged, ensure the blower housing is clear of any

 

 

 

 

condensation.

 

 

The gas control valve/thermostat

2

Check vent temperature limit switch - if it is determined

 

 

has detected the air pressure switch

 

that the vent temperature limit switch is opening its

 

 

circuit is opening repeatedly during

 

contacts at normal operating temperatures during

 

 

one heating cycle.

 

heating cycle - replace the vent temperature limit

 

 

 

 

switch.

 

 

 

3

Ensure water heater is not over-firing. Call the technical

 

 

 

 

support for further assistance.

 

 

 

 

 

36

Image 36
Contents Whenever maintenance adjustment or service is required Printed197425-005 Safe INSTALLATION, USE and Service ApprovalsImportant Definitions General Safety Information General Safety Information Table of Contents IntroductionInstallation of Carbon Monoxide Detectors Approved Carbon Monoxide DetectorsSignage ExemptionsTypical Installation Replacement Parts and Deliming ProductsElbow Access Door Condensate Hose and Drain PAN Mixing Valves Less Severe Burns 2nd & 3rd DegreeLocating the NEW Water Heater Facts to Consider About the LocationInsulation Blankets Air REQUIREMENTsUnconfined Space Confined SpaceFresh Air Openings For Confined Spaces Outdoor Air Through Two OpeningsOutdoor AIR Through TWO Horizontal Ducts Outdoor AIR Through TWO Vertical DuctsAIR from Other Indoor Spaces Installing the NEW Water Heater Chemical Vapor CorrosionWater Piping Space Heating and Potable Water SystemTemperature-Pressure Relief Valve Thermal ExpansionValve and Pipe Insulation High Altitude Installation Gas PipingSediment Traps Filling the Water HeaterVent Pipe Assembly VentingTermination Clearances Sidewall Power Vent Vent Pipe TerminationPlanning the Vent System CondensateBreathing Hazard Carbon Monoxide Gas Blower Assembly Installation Installation of Vent SystemVent Terminal INSTALLATION, Sidewall Sequence of INSTALLATIONS, Figure Power Vent Wiring Schematic FigureVent Termination Figure Installation of Vent SYSTEM, Sidewall Installation of Vertical Vent SystemVent Attenuation Assembly Installation Vertical VAA Installations RecommendedInch vent Vertical VAA Installations Vent Pipe Preparation Recommended BRUSH* Size for Primer Cement ApplicationsStep B Step EStep F Step GPage Temperature Regulation GAS Control Valve Front ViewPeriodic Maintenance For Your InformationStart UP Conditions Operational ConditionsBurner Cleaning Burner Operation and InspectionHousekeeping Anode ROD InspectionTemperature-Pressure Relief Valve Test Draining and FlushingTo Drain the Water Heater Storage Tank To Flush the Water Heater Storage TankService Leakage CheckpointsRepair Parts List Troubleshooting Guidelines Trouble ShootingLED Status Problem Solution LED Status Problem Solution Troubleshooting Guidelines Page ServIce and laBor responsIBIlItY ClaIM procedureCondItIons and eXceptIons LIMItatIon on IMplIed warrantIesCopyright 2010 State Industries, Inc. All rights reserved