FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppliers instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.

STOP! Read safety information above on this label.

9.

Push in control knob all the way and hold down.

2.

Set the thermostat to lowest setting by turning the

 

Immediately light the pilot with a match. Continue to hold

 

water temperature dial clockwise (

) to its lowest

 

control knob in for about one (1) minute after the pilot is

 

temperature setting (with arrow on dial) as shown.

 

lit. Release knob and it will pop back up. Pilot should

 

DO NOT FORCE.

 

 

 

 

 

remain lit. If it goes out, repeat steps 3 through 8.

3.

Remove outer door.

 

 

 

 

• If knob does not pop up when released, stop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and immediately call your service technician

 

 

 

 

 

 

 

or gas supplier.

 

 

 

 

 

 

 

 

• If the pilot will not stay lit after several tries,

 

 

 

 

 

 

 

 

depress and turn the gas control knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clockwise

to “OFF” and call your

4.

Turn gas control knob clockwise

to “OFF”

 

service technician or gas supplier.

 

position. Knob cannot be turned from “PILOT” to “OFF”

10.

Replace (or close) inner door. Replace outer

 

unless knob is depressed slightly. DO NOT FORCE.

 

 

door if door does not cover gas control on/off

5.

Wait five (5) minutes to clear out any gas. If you

 

 

knob or temperature adjustment knob.

 

then smell gas, STOP! Follow “B” in the safety

 

 

11.

At arms length away, turn gas control knob

 

information above on this label. If you don't smell gas,

 

go to next step.

 

 

 

 

 

counter- clockwise

to the full “ON”

6.

Remove (or open) inner door located below gas

 

position. WARNING: Do not use gas control

 

control unit.

 

 

 

 

 

knob to regulate gas flow.

7.

Find pilot - follow metal tube from gas control. The pilot

 

12.

At arms length away, set the thermostat to

 

is located in front of the burner or on the right hand

 

 

desired setting. The

mark ( ) indicative of

 

side of the burner.

 

 

 

 

 

PILOT

 

approximate 120°F is preferred starting point.

 

PILOT

 

 

 

 

BURNER

 

Some local laws may require a lower starting

 

BURNER

 

 

 

OR

 

 

 

 

 

*THERMOCOUPLE

 

point. If hotter water is desired, see instruction

 

 

 

 

 

 

 

 

 

 

manual and “warning” below.

8.

If you don’t smell gas, turn knob on gas control counter

 

 

clockwise

 

to “PILOT” position.

13.

Replace the outer door if not replaced in step 10.

WARNING

Hotter water increases the risk of scald injury. Before changing temperature setting see instruction manual.

TO TURN OFF GAS TO APPLIANCE

1. Set the thermostat to lowest setting by turning the water

2.

Turn gas control knob clockwise

to “OFF”

temperature dial clockwise (

) to its lowest

 

position. Knob cannot be turned from “PILOT” to “OFF”

temperature setting (with arrow on dial) as shown. DO

 

unless knob is depressed slightly. DO NOT FORCE.

NOT FORCE.

 

 

 

3.

Replace outer door (if removed).

 

 

 

 

10

Image 10
Contents Installation Operation Service Maintenance Limited Warranty Commercial GAS Water HeaterDimensions Recovery CapacitiesTable of Contents Insulation Blankets Installation InstructionsHigh Altitude Installations Required AbilityAIR Requirements ClearancesHard Water Combination Water Potable Heating and Space HeatingSystem Connections VentingRelief Valve DrafthoodSingle Temperature GAS PipingGAS Pressure Regulator PurgingGAS Meter Size Natural GAS only Manifold Pressure Setting OperationFor Your Safety Read Before Lighting High Temperature Limit Switch Temperature RegulationChecking Venting Checking GAS Input Service InformationPilot and Main Burner Pilot and Main BurnerChecklist Water Leakage is Suspected Water Temperature is TOO HOTGAS Smellat the Heater Water Heater Makes Sounds

196114-000 specifications

State Industries 196114-000 is a prominent model in the realm of water heaters, designed to meet the diverse needs of modern households and commercial establishments. Renowned for its reliability and efficiency, this unit embodies advanced technologies that ensure optimal performance, durability, and energy savings.

One of the primary features of the 196114-000 is its high-capacity water tank, which is constructed from robust materials that resist corrosion and wear. This not only extends the lifespan of the unit but also ensures that hot water is readily available for various applications, whether it's for cooking, cleaning, or bathing. The tank's insulation aids in maintaining water temperature, reducing energy consumption and costs over time.

In terms of technology, the State Industries 196114-000 incorporates state-of-the-art heating elements that provide rapid heating of water. These elements are designed for efficiency, which translates into faster recovery rates and consistent water temperature. Additionally, the system employs smart control mechanisms that monitor water usage and adjust heating cycles accordingly, enhancing energy efficiency without compromising performance.

Safety features are another critical aspect of the 196114-000. It includes automatic shut-off functionalities, which protect against overheating and pressure build-up. This ensures not only the longevity of the unit but also safeguards users from potential hazards associated with malfunctioning water heaters.

The design of the 196114-000 is user-friendly, featuring an intuitive control panel that allows for easy temperature adjustments and monitoring. Maintenance is also simplified, with accessible components that make servicing straightforward and wear part replacement feasible without specialized tools.

Moreover, the compatibility of the State Industries 196114-000 with various installation configurations makes it a versatile choice for both residential and commercial applications. Its compact size allows for floor or wall mounting, catering to spaces with limited square footage.

In conclusion, the State Industries 196114-000 stands out in the competitive market of water heaters due to its blend of efficiency, safety, and advanced technology. Whether you're looking to upgrade your current system or install a new unit, this model promises reliable hot water supply and cost-effective operation, making it a trusted choice for countless users.