State Industries 196114-000 Temperature Regulation, High Temperature Limit Switch

Page 11

TEMPERATURE REGULATION

DANGER

THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE THERMOSTAT TO CONTROL WATER TEMPERATURE. HOT WATER TEMPERATURES REQUIRED FOR AUTOMATIC DISHWASHER AND LAUNDRY USE CAN CAUSE PAINFUL SCALDING WITH POSSIBLE SERIOUS AND PERMANENT INJURY. THE TEMPERATURE AT WHICH INJURY OCCURS VARIES WITH THE PERSON’S AGE AND THE TIME OF THE EXPOSURE. THE SLOWER RESPONSE TIME OF CHILDREN, AGED OR DISABLED PERSONS INCREASES THE HAZARDS TO THEM. NEVER ALLOW SMALL CHILDREN TO USE A HOT WATER TAP, OR TO DRAW THEIR OWN BATH WATER. NEVER LEAVE A CHILD OR DISABLED PERSON UNATTENDED IN A BATHTUB OR SHOWER.

THE WATER HEATER SHOULD BE LOCATED IN AN AREA WHERE THE GENERAL PUBLIC DOES NOT HAVE ACCESS. IF A SUITABLE AREAIS NOTAVAILABLE,ACOVER SHOULD BE INSTALLED OVER THE THERMOSTAT TO PREVENT TAMPERING. Suitable covers are available from your distributor.

It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all cases, that the water temperature dial be set for the lowest temperature which satisfies your hot water needs. This will also provide the most energy efficient operation of the water heater. The water temperature adjusting dial was factory set at the lowest temperature; all the way clockwise to the mechanical stop. Turning the dial counterclockwise increases temperature and clockwise reduces temperature.

SETTING THE WATER HEATER TEMPERATURE AT 120°F (49°C)

(APPROX. "" MARK ON FACE OF THERMOSTAT) WILL REDUCE THE RISK OF SCALDS. Some states require settings at specific lower temperatures.

Figure 6 shows the approximate water temperatures produced at various thermostat dial settings. Short repeated heating cycles caused by small hot water uses can cause temperatures at the point of use to exceed the thermostat setting by up to 30°F (17°C). If you experience this type of use you should consider using lower temperature settings to reduce scald hazards.

Valves for reducing point of use temperature by mixing cold and hot water are available. Also available are inexpensive devices that attach to faucets to limit hot water temperatures. Contact a licensed plumber or the local plumbing authority.

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, TURN OFF THE MAIN MANUAL GAS Shut-off VALVE TO THE APPLIANCE.

Temperature

Time to Produce 2nd & 3rd

Setting

Degree Burns on Adult Skin

 

 

VERY HOT = APPROX.180°F (82°C)

Nearly instantaneous

D = APROX. 160°F (71°C)

About 1/2 second

C = APPROX.150°F (66°C)

About 1 1/2 seconds

B = APPROX.140°F (60°C)

Less than 5 seconds

A = APPROX.130°F (54°C)

About 30 seconds

= APPROX.120°F (49°C)

More than 5 minutes

LOW = APPROX.100°F (38°C)

- - - - - - - -

 

 

FIGURE6

HIGH TEMPERATURE LIMIT SWITCH

(Single-Use Type Energy Cut Off)

The thermostat has a built-in limit switch which will extinguish the pilot light in case of excessive water temperatures. The pilot cannot be relit until the entire thermostat (labeled as single use type) is replaced. It is important that a serviceman be called to determine the reason for limit operation and thus avoid repeated thermostat replacement. Lower the temperature adjustment dial setting on new control.

CHECKING VENTING

The following steps shall be followed with each appliance connected to the venting system placed in operation, while any other appliances connected to the venting system are not in operation.

1.Seal any unused openings in the venting system.

2.Inspect the venting system for proper size and horizontal pitch, as required in the National Fuel Gas Code, ANSI Z223.1 or the CAN/CGA B149 Installation codes and these instructions. Determine that there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition.

3.So far as is practical, close all building doors and windows and all doors between the space in which the water heater(s) connected to the venting system are located and other spaces of the building. Turn on all appliances not connected to the venting system. Turn on all exhaust fans, such as range hoods

11

Image 11
Contents Commercial GAS Water Heater Installation Operation Service Maintenance Limited WarrantyRecovery Capacities DimensionsTable of Contents Required Ability Installation InstructionsHigh Altitude Installations Insulation BlanketsCombination Water Potable Heating and Space Heating ClearancesHard Water AIR RequirementsDrafthood VentingRelief Valve System ConnectionsGAS Piping Single TemperatureGAS Meter Size Natural GAS only PurgingGAS Pressure Regulator Operation Manifold Pressure SettingFor Your Safety Read Before Lighting Checking Venting Temperature RegulationHigh Temperature Limit Switch Pilot and Main Burner Service InformationPilot and Main Burner Checking GAS InputChecklist Water Heater Makes Sounds Water Temperature is TOO HOTGAS Smellat the Heater Water Leakage is Suspected

196114-000 specifications

State Industries 196114-000 is a prominent model in the realm of water heaters, designed to meet the diverse needs of modern households and commercial establishments. Renowned for its reliability and efficiency, this unit embodies advanced technologies that ensure optimal performance, durability, and energy savings.

One of the primary features of the 196114-000 is its high-capacity water tank, which is constructed from robust materials that resist corrosion and wear. This not only extends the lifespan of the unit but also ensures that hot water is readily available for various applications, whether it's for cooking, cleaning, or bathing. The tank's insulation aids in maintaining water temperature, reducing energy consumption and costs over time.

In terms of technology, the State Industries 196114-000 incorporates state-of-the-art heating elements that provide rapid heating of water. These elements are designed for efficiency, which translates into faster recovery rates and consistent water temperature. Additionally, the system employs smart control mechanisms that monitor water usage and adjust heating cycles accordingly, enhancing energy efficiency without compromising performance.

Safety features are another critical aspect of the 196114-000. It includes automatic shut-off functionalities, which protect against overheating and pressure build-up. This ensures not only the longevity of the unit but also safeguards users from potential hazards associated with malfunctioning water heaters.

The design of the 196114-000 is user-friendly, featuring an intuitive control panel that allows for easy temperature adjustments and monitoring. Maintenance is also simplified, with accessible components that make servicing straightforward and wear part replacement feasible without specialized tools.

Moreover, the compatibility of the State Industries 196114-000 with various installation configurations makes it a versatile choice for both residential and commercial applications. Its compact size allows for floor or wall mounting, catering to spaces with limited square footage.

In conclusion, the State Industries 196114-000 stands out in the competitive market of water heaters due to its blend of efficiency, safety, and advanced technology. Whether you're looking to upgrade your current system or install a new unit, this model promises reliable hot water supply and cost-effective operation, making it a trusted choice for countless users.