State Industries 196114-000 Purging, GAS Pressure Regulator, GAS Meter Size Natural GAS only

Page 8

TABLE 1 - GAS SUPPLY LINE SIZES (IN INCHES)*

MAXIMUM CAPACITY OF PIPE IN

CUBIC FEET PER HOUR

LENGTH

 

 

NORMAL IRON PIPE SIZES (INCHES)

 

 

IN

 

 

INPUT IN THOUSANDS BTU/HR

 

 

 

FEET

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

2 1/2"

3"

4"

 

10

175

360

680

1400

2100

3960

6300

11000

23000

 

20

120

250

485

950

1460

2750

4360

7700

15800

 

30

97

200

375

770

1180

2200

3520

6250

12800

 

40

82

170

320

660

990

1900

3000

5300

10900

 

50

73

151

285

580

900

1680

2650

4750

9700

 

60

66

138

260

530

810

1520

2400

4300

8800

 

70

61

125

240

490

750

1400

2250

3900

8100

 

80

57

118

220

460

690

1300

2050

3700

7500

 

90

53

110

205

430

650

1220

1950

3450

7200

 

100

50

103

195

400

620

1150

1850

3250

6700

 

125

44

93

175

360

550

1020

1650

2950

6000

 

150

40

84

160

325

500

950

1500

2650

5500

 

175

37

77

145

300

460

850

1370

2450

5000

 

200

35

72

135

280

430

800

1280

2280

4600

 

LENGTH

 

 

NORMAL IRON PIPE SIZES (INCHES)

 

IN

 

 

INPUT IN KW

 

 

 

 

METERS

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

2 1/2"

3"

4"

3

51

105

199

410

615

1160

1845

3221

6735

6

35

73

142

278

428

805

1277

2255

4626

9

28

59

110

225

346

644

1031

1830

3748

12

24

50

94

193

290

556

878

1552

3192

15

21

44

83

170

264

492

776

1391

2840

18

19

40

76

155

237

445

703

1259

2577

21

18

37

70

143

220

410

659

1142

2372

24

17

35

64

135

202

381

600

1083

2196

27

16

32

60

126

190

357

571

1010

2108

31

15

30

57

117

182

337

542

952

1962

38

13

27

51

105

161

299

483

864

1757

46

12

25

47

95

146

278

439

776

1610

53

11

23

42

88

135

249

401

717

1464

61

10

21

40

82

126

234

375

688

1347

PRESSURE TESTING EXCEEDING 1/2 PSIG (3.45 Kpa). GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEATER. FOR TEST PRESSURES OF 1/2 PSIG (3.45 Kpa) OR LESS THE APPLIANCE NEED NOT BE DISCONNECTED, BUT MUST BE ISOLATED FROM THE SUPPLY PRESSURE TEST BY CLOSING THE MANUAL GAS Shut-off VALVE.

PURGING

Gas line purging is required with new piping or systems in which air has entered.

CAUTION

PURGING SHOULD BE PERFORMED BY PERSONS EXPERIENCED IN THIS TYPE GAS SERVICE. TO AVOID RISK OF FIRE OR EXPLOSION, PURGE DISCHARGE MUST NOT ENTER CONFINED AREAS OR SPACES WHERE IGNITION CAN OCCUR. THE AREA MUST BE WELL VENTILATED AND ALL SOURCES OF IGNITION MUST BE INACTIVATED OR REMOVED.

GAS METER SIZE — NATURAL GAS ONLY

Be sure the gas meter has sufficient capacity to supply the full rated gas input of the water heater as well as the requirements of all other gas fired equipment supplied by the meter. If gas meter is too small, ask the gas company to install a larger meter having adequate capacity.

To prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to gas valve inlet.

Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compounds to the first two threads. Use compounds resistant to the action of liquefied petroleum gases.

BEFORE PLACING THE HEATER IN OPERATION, CHECK FOR GAS LEAKAGE. Use soap and water solution or other material acceptable for the purpose in locating the leaks. DO NOT USE MATCHES, CANDLES, FLAME OR OTHER SOURCES OF IGNITION FOR THIS PURPOSE.

FIGURE 4 - GAS PIPING AND DIRT LEG INSTALLATION

DISCONNECT THE HEATER AND ITS MANUAL GAS Shut-off VALVE FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY SUPPLY

FIGURE 5 -THERMOSTAT FOR NATURAL GAS

GAS PRESSURE REGULATOR

The gas pressure regulator is built into the gas valve and is equipped to operate on the gas specified on model and rating plate. The regulator is factory adjusted to deliver gas to burner at correct water column pressure allowing for a nominal pressure drop through the controls.

The minimum gas supply pressure for input adjustment is 5.0" W.C. (1.24 kPa) for natural gas or 11.0" W.C. (2.74 kPa) for propane gas.

Do not subject the combination gas valve to inlet gas pressures of more than 10.5" W.C. (2.61 kPa) - natural gas or 13.0" W.C. (3.23 kPa) - propane gas. A service regulator is necessary if higher gas pressures are encountered.

Gas pressure specified in Table 2, refer to flow pressure taken at pressure tap of automatic gas valve while heater is operating.

8

Image 8
Contents Installation Operation Service Maintenance Limited Warranty Commercial GAS Water HeaterDimensions Recovery CapacitiesTable of Contents Installation Instructions High Altitude InstallationsInsulation Blankets Required AbilityClearances Hard WaterAIR Requirements Combination Water Potable Heating and Space HeatingVenting Relief ValveSystem Connections DrafthoodSingle Temperature GAS PipingGAS Meter Size Natural GAS only PurgingGAS Pressure Regulator Manifold Pressure Setting OperationFor Your Safety Read Before Lighting Checking Venting Temperature RegulationHigh Temperature Limit Switch Service Information Pilot and Main BurnerChecking GAS Input Pilot and Main BurnerChecklist Water Temperature is TOO HOT GAS Smellat the HeaterWater Leakage is Suspected Water Heater Makes Sounds

196114-000 specifications

State Industries 196114-000 is a prominent model in the realm of water heaters, designed to meet the diverse needs of modern households and commercial establishments. Renowned for its reliability and efficiency, this unit embodies advanced technologies that ensure optimal performance, durability, and energy savings.

One of the primary features of the 196114-000 is its high-capacity water tank, which is constructed from robust materials that resist corrosion and wear. This not only extends the lifespan of the unit but also ensures that hot water is readily available for various applications, whether it's for cooking, cleaning, or bathing. The tank's insulation aids in maintaining water temperature, reducing energy consumption and costs over time.

In terms of technology, the State Industries 196114-000 incorporates state-of-the-art heating elements that provide rapid heating of water. These elements are designed for efficiency, which translates into faster recovery rates and consistent water temperature. Additionally, the system employs smart control mechanisms that monitor water usage and adjust heating cycles accordingly, enhancing energy efficiency without compromising performance.

Safety features are another critical aspect of the 196114-000. It includes automatic shut-off functionalities, which protect against overheating and pressure build-up. This ensures not only the longevity of the unit but also safeguards users from potential hazards associated with malfunctioning water heaters.

The design of the 196114-000 is user-friendly, featuring an intuitive control panel that allows for easy temperature adjustments and monitoring. Maintenance is also simplified, with accessible components that make servicing straightforward and wear part replacement feasible without specialized tools.

Moreover, the compatibility of the State Industries 196114-000 with various installation configurations makes it a versatile choice for both residential and commercial applications. Its compact size allows for floor or wall mounting, catering to spaces with limited square footage.

In conclusion, the State Industries 196114-000 stands out in the competitive market of water heaters due to its blend of efficiency, safety, and advanced technology. Whether you're looking to upgrade your current system or install a new unit, this model promises reliable hot water supply and cost-effective operation, making it a trusted choice for countless users.