Switch Fabric | ■ | Full digital, nonblocking |
|
|
|
Electrical | ■ | 10 Watts (35 BTU/hour) per 400 module, normal and maximum power consumption |
Specifications | ■ | 65 Watts (225 BTU/hour) per 206 module during normal operation |
| ■ | 100 Watts (350 BTU/hour) per 206 module during maximum power consumption |
|
| |
| ■ | U.S., Canada, and other 110V countries: 8 Amps maximum current at full system capacity (two |
|
| carriers with processor module and four 206 modules each) |
|
| Countries using 220V: 4.4 Amps maximum current (two carriers with processor module and four |
|
| 206 modules each) |
| ■ | |
|
|
|
Primary | ■ | 68000 microprocessor, 256Kbytes RAM, 512Kbytes ROM |
Processor Module |
|
|
Specifications |
|
|
|
| |
Expansion | ■ 8051 microprocessor, 12mHz, 8Kbytes ROM | |
Processor Module |
|
|
Specifications |
|
|
|
|
|
Extension Jack | ■ | Ringing voltage: +5VDC, |
Specifications | ■ | 35- to |
| ■ | Ringing frequency: 20 Hz |
|
|
|
PAGE Jack | ■ | Draws current on inner wire pair |
Specifications | ■ | Provides contact closure on outer wire pair |
| ■ | 600 Ohm impedance |
|
|
|
SMDR Output | ■ | 1200 baud |
Format | ■ | No parity |
| ■ | 8 data bits |
| ■ | 2 stop bits |
|
| |
| ■ | XON/XOFF protocol |
| ■ | Carriage return |
| ■ | Line feeds |
Environmental
Requirements—
Control Unit
■Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
■Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded electrical outlet not controlled by a switch, using supplied
■Mount the Expansion Carrier at least 6” and not more than 24” away from the Primary Carrier
■Operating temperature 32° to +104°F (0° to +40°C), not in direct sunlight
■Humidity
■For proper ventilation and easy replacement of modules, provide at least 6“ (15.2 cm) clearance at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.
■Locate in an area free of excess moisture, corrosive gases, dust, and chemicals