Switch Fabric

■

Full digital, nonblocking

 

 

 

Electrical

■

10 Watts (35 BTU/hour) per 400 module, normal and maximum power consumption

Specifications

■

65 Watts (225 BTU/hour) per 206 module during normal operation

 

■

100 Watts (350 BTU/hour) per 206 module during maximum power consumption

 

 

 

■

U.S., Canada, and other 110V countries: 8 Amps maximum current at full system capacity (two

 

 

carriers with processor module and four 206 modules each)

 

 

Countries using 220V: 4.4 Amps maximum current (two carriers with processor module and four

 

 

206 modules each)

 

■

4-day memory backup (96 hours)

 

 

 

Primary

■

68000 microprocessor, 256Kbytes RAM, 512Kbytes ROM

Processor Module

 

 

Specifications

 

 

 

 

Expansion

■ 8051 microprocessor, 12mHz, 8Kbytes ROM

Processor Module

 

 

Specifications

 

 

 

 

 

Extension Jack

■

Ringing voltage: +5VDC, -140 VDC peak to peak; trapezoidal wave shaping

Specifications

■

35- to 38-Volt talk battery

 

■

Ringing frequency: 20 Hz

 

 

 

PAGE Jack

■

Draws current on inner wire pair

Specifications

■

Provides contact closure on outer wire pair

 

■

600 Ohm impedance

 

 

 

SMDR Output

■

1200 baud

Format

■

No parity

 

■

8 data bits

 

■

2 stop bits

 

 

 

■

XON/XOFF protocol

 

■

Carriage return

 

■

Line feeds

Environmental

Requirements—

Control Unit

■Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)

■Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded electrical outlet not controlled by a switch, using supplied 7-foot (2.1-meter) cords

■Mount the Expansion Carrier at least 6” and not more than 24” away from the Primary Carrier

■Operating temperature 32° to +104°F (0° to +40°C), not in direct sunlight

■Humidity 15%–90%, noncondensing

■For proper ventilation and easy replacement of modules, provide at least 6“ (15.2 cm) clearance at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.

■Locate in an area free of excess moisture, corrosive gases, dust, and chemicals

A-2Specifications

Page 324
Image 324
Lucent Technologies 4.1 manual 2Specifications