System Programming Quick Reference

Place the Programming Overlay on the dialpad of the system display phone at extension 10 or 11

TO START SYSTEM PROGRAMMING

PRESS [ Feature ] [ 0 ] [ 0 ]

PRESS [ System Program ]

PRESS [ System Program ]

TO END SYSTEM PROGRAMMING

PRESS [ Feature ] [ 0 ] [ 0 ]

TO USE A SPECIFIC PROCEDURE

DIAL [ # ] and three-digit procedure code

Example: [ # ] [ 1 ] [ 0 ] [ 1 ] for System Date

TO CYCLE THROUGH SYSTEM

TO CYCLE THROUGH

PROGRAMMING PROCEDURES

AVAILABLE SETTINGS

PRESS [ Next Procedure ] or [ Prev Procedure ]

PRESS [

Next Data

] or [

Prev Data

]

 

 

 

 

 

 

 

TO RETURN TO FACTORY

NOTES: Procedures #399, #609,

and #728—shown below in dashed

SETTING

boxes—are skipped when cycling.

PRESS [ Remove ]

System

SYSTEM DATE

(p. 5-178)

DIAL #101

DIAL the date in MMDDYY form

SYSTEM DAY

 

(p. 5-179)

DIAL #102

 

 

DIAL 1 = Sunday 5

= Thursday

2

= Monday

6

= Friday

3

= Tuesday

7

= Saturday

4

= Wednesday

 

 

 

 

 

 

 

 

SYSTEM TIME

 

(p. 5-185)

DIAL #103

DIAL the time in HHMM 24-hour military format

NUMBER OF LINES (p. 5-143)

*See IMPORTANT below DIAL #104

DIAL two digits (01–24) for the number of outside lines to be assigned to every extension

2 per 206 or 200 module

4 per 400 module

TRANSFER RETURN RINGS

DIAL #105

(p. 5-194)

DIAL one digit (0–9) for the number of rings before the call returns

= 4 rings

0 rings = no return

RECALL TIMER DURATION

AUTOMATIC SYSTEM ANSWER BUTTON

DIAL #111

(p. 5-21)

DIAL 1

= Assigned

 

2

= Not Assigned

 

3 = Select Button then press

 

a programmable button

 

 

 

 

DIRECT EXTENSION DIAL DELAY

DIAL #112

(p. 5-62)

DIAL a ring delay number (0–9)

= 2 rings

DIRECT EXTENSION DIAL BUTTON

DIAL #113

(p. 5-59)

DIAL 1 = Assigned

2 = Not Assigned

3 = Select Button then press

 

a programmable button

OUTGOING CALL RESTRICTION

BUTTON

(p. 5-146)

DIAL #114

DIAL 1 = Assigned

2 = Not Assigned

3 = Select Button then press a programmable button

WAKE UP SERVICE BUTTON

DIAL #115

(p. 5-204)

DIAL 1 = Assigned

2 = Not Assigned

3 = Select Button then press

a programmable button

 

Lines

DIAL MODE

(p. 5-58)

DIAL #201

DIAL a line number (01–24)

DIAL 1 = Touch-Tone

2 = Rotary

PRESS [ Next Item ] to program another

line

HOLD DISCONNECT TIME

DIAL #203

(p. 5-106)

DIAL a line number (01–24) DIAL 1 = Long (450 msec)

2 = Short (50 msec) PRESS [ Next Item ] to program another

 

line

AUTOMATIC SYSTEM ANSWER

LINES

(p. 5-25)

DIAL #204

DIAL a line number (01–24) DIAL 1 = Assigned

2 = Not Assigned PRESS [ Next Item ] to program another

line

DIRECT EXTENSION DIAL LINES

DIAL

#205

(p. 5-63)

DIAL

a line number (01–24)

DIAL 1 = Assigned

2 = Not Assigned

PRESS [ Next Item ] to program another line

GROUP CALL DISTRIBUTION

DIAL #206

(p. 5-94)

DIAL

a group number

 

 

(1–6, 7 for VMS)

 

DIAL

a line number (01–24)

DIAL

1

= Assigned

 

 

2

= Not Assigned

 

3 = VMS Line Cover (only for hunt group 7)

PRESS [ Next Item ] to program another

line

POOL LINE ASSIGNMENT

DIAL #207

(p. 5-157)

DIAL a line number (01–24)

DIAL 1 = No Pool

2 = Main Pool 880

3 = Pool 881

4 = Pool 882

5 = Pool 883 PRESS [ Next Item ] to program

another line

LINE COVERAGE EXTENSION

DIAL #208

(p. 5-122)

DIAL a line number (01–24)

DIAL an extension number (10–57)

PRESS [ Next Item ] to program another line

PRESS [ Remove ] to unassign

ownership

DIAL #107

(p. 5-162)

DIAL two digits (01–80) to set the length of a switchhook flash

= 18 (450 msec)

ROTARY DIALING TIMEOUT

DIAL #108

(p. 5-164)

DIAL

1 = 4 sec

3 = 12 sec

 

2 = 8 sec

 

 

 

OUTSIDE CONFERENCE DENIAL

DIAL #109

(p. 5-148)

DIAL

1 = Allowed

 

2 = Disallowed

 

 

AUTOMATIC SYSTEM ANSWER

DELAY

 

DIAL #110

(p. 5-24)

DIAL a ring delay number (0–9)

= 2 rings

CALL COVERAGE RINGS

DIAL #116

(p. 5-40)

DIAL one digit (1–9) for the number of rings before the call is sent to the covering extension

= 2 rings

VMS COVER RINGS (p. 5-197)

DIAL #117

DIAL one digit (1–9) for the number of rings before the call is sent to the voice messaging system

= 3 rings

RING ON TRANSFER (p. 5-163)

DIAL #119

DIAL 1 = Active

2 = Not Active

AUTOMATIC SYSTEM ANSWER MODE

DIAL #121

(p. 5-27)

DIAL 1 = Hold

2 = Disconnect

3 = Ring

Procedures #207, #313, #314 and #315—shown in square dotted boxes— are not available when the system is configured for Key mode.

IMPORTANT: In Key mode, the Number of Lines procedure changes Line Assignment (#301), Line Access Restriction (#302), Automatic Line Selection, and Line Ringing to factory settings. To change line assignments without affecting other settings, use Line Assignment (#301).

In Hybrid mode, the Number of Lines procedure changes Pool Line Assign- ment (#207), Pool Extension Assignment (#314), and Pool Access Restriction (#315) for existing pools back to factory settings. Additionally, it changes Line Assignment (#301), Line Access Restriction (#302), Automatic Line Selection, and Line Ringing for individual lines back to factory settings. To change pool assignments without affecting other settings, use Pool Line Assignment (#207) and Pool Extension Assignment (#314).

For Centralized Telephone Programming, see previous pages

Page 359
Image 359
Lucent Technologies 4.1 System Programming Quick Reference, For Centralized Telephone Programming, see previous pages