Problems with Combination Extensions

Phone Does Not Work Properly

Possible Cause 1: Ringer equivalents are too high for the extension.

What to do: Be sure the total of the two devices’ Ringer Equivalence Numbers (REN) does not exceed 2.0. If it does, unplug one of the devices.

■If the phone works properly, the problem is the REN was too high.

■If the phone still does not work properly, go to Possible Cause 2.

Possible Cause 2: Auxiliary device (such as a fax, answering machine, or modem) is faulty.

What to do: Remove the auxiliary device from the extension. Then plug in an auxiliary device that you know works properly.

■If the phone works properly, the problem is the auxiliary device. Replace the auxiliary device.

■If the phone still does not work properly, go to Possible Cause 3.

Possible Cause 3: Phone is plugged into the wrong jack of the system phone or the bridging adapter.

What to do: Plug the phone into the correct jack—see the PARTNER II Communications System Installation guide for instructions.

■If the phone works properly, the problem is solved.

■If the problem remains, go to Possible Cause 4.

Possible Cause 4: Wrong bridging adapter is used in combination extension.

What to do: First, unplug the bridging adapter from the wall jack. Then, unplug the phone from the adapter and plug the phone directly into the wall jack.

■If the phone works, there is a problem with the bridging adapter. Replace the bridging adapter (use only a Lucent Technologies 267F2 bridging adapter). If the problem persists, call the hotline.*

■If the phone still does not work properly, call the hotline.*

✽In the continental U.S., help is available at 1 800 628-2888. Outside the continental U.S., call your Lucent Technologies Representative or local Authorized Dealer.

Troubleshooting 6-13

Page 318
Image 318
Lucent Technologies 4.1 manual Problems with Combination Extensions, Phone Does Not Work Properly