Problems with Auxiliary Equipment

Standard Device Does Not Answer

Possible Cause: A standard device (such as a fax machine or answering machine) does not answer intercom calls or transferred calls because it does not recognize the distinctive ringing pattern used by the system.

What to do: Change the extension’s setting for Distinctive Ring (#308) to Not Active, so the extension uses the same ringing for intercom and transferred calls as it does for outside calls.

■If the device works properly, the problem is solved.

■If the problem remains, call the hotline.*

Standard Device Does Not Dial Out Properly

Possible Cause: A standard device with autodialing (such as a modem) does not recognize the intercom dial tone generated by the system.

What to do: Change the setting for Intercom Dial Tone (#309) for the extension to Machine, so the system generates outside line dial tone for the extension.

■If the device works properly, the problem is solved.

■If the problem remains, call the hotline.*

Poor Transmission Quality on Modem

Possible Cause: A high-speed modem is connected through an extension jack on the control unit to a standard central office telephone line; but the line quality is not sufficient to generate a clear signal when the modem transmits through the system interface.

What to do: Either connect the modem directly to the network interface jack for a line, or contact your local telephone company for information about upgrading the line quality.

■If the device works properly, the problem is solved.

■If the problem remains, call the hotline.*

Call Records Wrap on SMDR Printout

Possible Cause: SMDR Talk Time (#611) is set to Active and SMDR Output Format (#610) is set to 24 digits, causing the combined length of the fields for a call record to be greater than the 80 characters supported by your printer.

What to do: Reduce the font size or increase the characters-per-inch setting for the printer.

■If the call records print without wrapping to the next line, the problem is solved.

■If the problem remains, change the output format back to 15 digits.